Just register your serial number – and enjoy the benefits.
Know-how! Learn how to make optimum use of BINDER technologies to achieve efficient processes.
There for you on-site – all thanks to the global BINDER Service organization.
What's new? Learn more in our news articles.
Simply subscribe and keep up to speed with the BINDER monthly newsletter.
Meet the specialists on simulation chambers. Where? Learn more here.
Do you have any questions or a specific request? Get in touch with us!
Do you have any questions? Here you can find the suitable contact person.
This is how you can find us!
Benefits
Important characteristics
Details of the model
Select version
RRP* [?] | Merken | |
---|---|---|
Model KBW 240 | ||
|
- | + |
Technical data
The PDF data sheet contains technical data, options & accessories as well as services.
Downloads
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
Rated voltage | Option model | Version | Art. No. | RRP* [?] | Selection | Bookmark |
---|---|---|---|---|---|---|
Model KBW 240 | ||||||
200…240 V 1~ 50 Hz | ||||||
Standard |
KBW240-230V | 9020-0338 | - | + |
Designation | Description | Art. No. | RRP* [?] | Bookmark | ||
---|---|---|---|---|---|---|
Access port with silicone plug | ||||||
left |
8012-1445 | - | + | |||
right |
8012-1439 | - | + | |||
left |
8012-1475 | - | + | |||
top |
8012-1457 | - | + | |||
right |
8012-1469 | - | + | |||
top |
8012-1463 | - | + | |||
top |
8012-1451 | - | + | |||
Alarm output, zero-voltage | ||||||
for temperature (±2 °C) and humidity (±5 % RH), accessible via 6-pin DIN socket (max. 24 V - 2.5 A), with audible signal that can be switched off |
8012-1757 | - | + | |||
Analog output 4-20 mA | ||||||
for temperature and humidity values (output not adjustable) |
8012-1721 | - | + | |||
Arabidopsis illumination | ||||||
Illumination cassettes equipped with Arabidopsis fluorescent tubes instead of daylight fluorescent tubes |
8012-0655 | - | + | |||
Calibration certificate, expanded | ||||||
for temperature; for extending the measurement in center of chamber to include another test temperature |
8012-1121 | - | + | |||
Calibration certificate, temperature | ||||||
temperature measurement incl. certificate and 27 measuring points at specified temperature |
8012-1599 | - | + | |||
temperature measurement incl. certificate, 9 measuring points at specified temperature |
8012-1557 | - | + | |||
temperature measurement incl. certificate, 15- 18 measuring points at specified temperature |
8012-1578 | - | + | |||
for temperature, measurement in center of chamber at specified temperature |
8012-1140 | - | + | |||
Class 3.3 independent temperature safety device | ||||||
with visual alarm (DIN 12880) |
8012-1750 | - | + | |||
Data Logger Kit | ||||||
T 220: For continuous temperature logging from -90 °C to 220 °C. The kit includes 1 data logger, Pt 100 sensor with 2 m extension cable and 1 magnetic fixture for mounting to the BINDER unit |
8012-0715 | - | + | |||
Data Logger Software | ||||||
LOG ANALYZE software kit, configuration and evaluation software for all BINDER Data Logger Kits (incl. USB data cable) |
8012-0821 | - | + | |||
Door lock | ||||||
lockable door handle |
8012-1775 | - | + | |||
FLUORA® illumination | ||||||
Illumination cassettes equipped with FLUORA® fluorescent tubes instead of daylight fluorescent tubes |
8012-0654 | - | + | |||
Interior socket | ||||||
Waterproof, switched flush-mounting box (CA3GD) for nominal voltage in unit interior, with cover and corresponding plug (nominal voltage; max. 500 W; max. 90 °C; protection class IP67) |
8012-1741 | - | + | |||
Light photometry | ||||||
including certificate, illumination and irradiance for visible light and UV-A, 25 measuring points on 3 measurement levels, as well as spectral distribution (250 – 785 nm) |
8012-0910 | - | + | |||
pH-neutral detergent | ||||||
concentrated, for gentle remove of residual contaminants; 1 kg |
1002-0016 | - | + | |||
Pt 100 temperature sensor | ||||||
additional flexible Pt 100, interior, for displaying the temperature on the unit display |
8012-1746 | - | + | |||
Qualification documents | ||||||
IQ/OQ documents – supporting documents for validation performed by customers, consisting of: IQ/OQ checklists incl. calibration guide and comprehensive unit documentation; parameters: temperature, humidity, and light values |
7057-0003 | - | + | |||
IQ/OQ/PQ documents – supporting documents for validation performed by customers, according to customer requirements, PQ section added to qualification folder IQ/OQ; parameters: temperature, humidity, and light values |
7007-0007 | - | + | |||
IQ/OQ/PQ documents – supporting documents for validation performed by customers, according to customer requirements, PQ section added to qualification folder IQ/OQ; parameters: temperature, humidity, and light values |
7057-0007 | - | + | |||
IQ/OQ documents – supporting documents for validation performed by customers, consisting of: IQ/OQ checklists incl. calibration guide and comprehensive unit documentation; parameters: temperature, humidity, and light values |
7007-0003 | - | + | |||
Rack | ||||||
|
6004-0101 | - | + | |||
Rack accessories | ||||||
fasteners (1 set of 4) for additional security of racks |
8012-0620 | - | + | |||
Rack, reinforced | ||||||
stainless steel, with fasteners (1 set of 4) |
8012-0638 | - | + | |||
RS 485 / RS 422 interface converter | ||||||
RS 422 cable set and RS 485 / RS 422 interface converter for connection to 10-way plug distributor |
8012-0589 | - | + | |||
RS 422 cable set and RS 485 / RS 422 interface converter for connection to 10-way plug distributor |
8012-0599 | - | + | |||
RS 485 interface, 2-wire | ||||||
Additional serial interface can be used parallel to Ethernet, for Multi Management Software APT-COM™ |
8012-1742 | - | + | |||
Shelf, perforated | ||||||
|
6004-0040 | - | + | |||
Shelf, reinforced | ||||||
positioned at bottom level, max. load 45 kg, with additional attachment for operation of shaking device, stirring device or roller bottle system |
8012-1429 | - | + | |||
Zero voltage relay contacts | ||||||
for controlling 3 relay contacts via program regulators, accessible via 6-pin DIN socket (max. 24 V - 2.5 A) |
8012-0679 | - | + |
Designation | Description | Art. No. | RRP* [?] | Bookmark | ||
---|---|---|---|---|---|---|
Calibration certificate, temperature |
Extension of calibration of one (1) additional test temperature specified by the user in the center of the usable space, including certificate |
DL30-0102 | - | + | ||
Calibration certificate, temperature |
Calibration of one (1) test temperature specified by the user in center of chamber including certificate |
DL30-0101 | - | + | ||
Execution of IQ/OQ incl. light photometry |
Execution of IQ/OQ including light photometry in accordance with qualification folder |
DL43-0400 | - | + | ||
Execution of IQ/OQ/PQ |
Execution of IQ/OQ/PQ in accordance with qualification folder |
DL44-0500 | - | + | ||
Maintenance |
Maintenance service in accordance with maintenance schedule. Visual inspection of mechanical and electrical components, testing of all key functions. Calibration of a test temperature specified by the user in center of chamber without certificate |
DL20-0400 | - | + | ||
Radiometric light photometry |
Radiometric measurement in the visible spectrum with determination and documentation of intensity distribution from an illumination cassette on 3 measurement levels, including certificate |
DL31-0000 | - | + | ||
Temperature measurement, 18 measuring points |
Temperature measurement with 18 measuring points with a set value specified by the user, including certificate |
DL30-0118 | - | + | ||
Temperature measurement, 27 measuring points |
Temperature measurement with 27 measuring points with a set value specified by the user, including certificate |
DL30-0127 | - | + | ||
Temperature measurement, 9 measuring points |
Temperature measurement with 9 measuring points with a set value specified by the user, including certificate |
DL30-0109 | - | + | ||
Unit commissioning |
Connect the unit to the customer-side connections (electricity, water, wastewater, gas), basic functions check, brief operating instructions. (excl.: unpacking, setup, controller instructions, programming, installation work) |
DL10-0300 | - | + | ||
Unit instructions |
Instruction regarding operating principle and basic functions of the unit, operation of the control electronics including programming |
DL10-0700 | - | + | ||
Warranty extension from 2 to 3 years |
The warranty is extended from 2 to 3 years from the delivery date, wear parts are excluded |
DL02-2041 | - | + | ||
Warranty extension from 2 to 5 years |
The warranty is extended from 2 to 5 years from the delivery date, wear parts are excluded |
DL02-2042 | - | + |
Designation |
KBW240-230V¹ |
---|---|
Option model | Standard |
Order number | 9020-0338 |
Data | |
Serie | KBW |
Performance Data Temperature | |
Temperature fluctuation with 100% illumination [± K] | 0.2 |
Temperature fluctuation without illumination cassettes [± K] | 0.1 |
Temperature range with 100% illumination [°C] | 5…60 |
Temperature range without illumination cassettes [°C] | 0…70 |
Temperature variation with 100% illumination [± K] | 0.5 |
Temperature variation without illumination cassettes [± K] | 0.5 |
Lightdata per Illumination Cassettes | |
Arabidopsis lamps [lx]* | 11000 |
Arabidopsis lamps [W/m²]* | 32 |
Daylight tubes [lx]* | 9000 |
Daylight tubes [W/m²]* | 24 |
Fluora® growth lamps [lx]* | 7500 |
Fluora® growth lamps [W/m²]* | 23 |
Electrical data | |
Nominal power [kW] | 1.4 |
Phase (Nominal voltage) | 1~ |
Power frequency [Hz] | 50 |
Rated Voltage [V] | 200…240 |
Unit fuse [A] | 16 |
Doors | |
Inner doors | 1 |
Unit doors | 1 |
Housing dimensions not incl. fittings and connections | |
Depth net [mm] | 800 |
Height net [mm] | 1465 |
Width net [mm] | 925 |
Internal Dimensions | |
Depth [mm] | 485 |
Height [mm] | 785 |
Width [mm] | 650 |
Measures | |
Interior volume [L] | 247 |
Load per rack [kg] | 30 |
Net weight of the unit (empty) [kg] | 202 |
Permitted load [kg] | 100 |
Wall clearance back [mm] | 100 |
Wall clearance sidewise [mm] | 100 |
Environment-specific data | |
Energy consumption at 37 °C and with illumination [Wh/h] | 450 |
Sound-pressure level [dB(A)] | 53 |
Fixtures | |
Number of illumination cassettes (std./max.) | 2/2 |
Number of shelves (std./max.) | 2/7 |
Performance Data Temperature | |
Temperature fluctuation with 100% illumination [± K] | 0.2 |
Temperature fluctuation without illumination cassettes [± K] | 0.1 |
Temperature range with 100% illumination [°C] | 5…60 |
Temperature range without illumination cassettes [°C] | 0…70 |
Temperature variation with 100% illumination [± K] | 0.5 |
Temperature variation without illumination cassettes [± K] | 0.5 |
Lightdata per Illumination Cassettes | |
Arabidopsis lamps [lx]* | 11000 |
Arabidopsis lamps [W/m²]* | 32 |
Daylight tubes [lx]* | 9000 |
Daylight tubes [W/m²]* | 24 |
Fluora® growth lamps [lx]* | 7500 |
Fluora® growth lamps [W/m²]* | 23 |
Electrical data | |
Nominal power [kW] | 1.4 |
Phase (Nominal voltage) | 1~ |
Power frequency [Hz] | 50 |
Rated Voltage [V] | 200…240 |
Unit fuse [A] | 16 |
Doors | |
Inner doors | 1 |
Unit doors | 1 |
Housing dimensions not incl. fittings and connections | |
Depth net [in] | 31.52 |
Height net [in] | 57.7 |
Width net [in] | 36.45 |
Internal Dimensions | |
Depth [in] | 19.11 |
Height [in] | 30.93 |
Width [in] | 25.61 |
Measures | |
Interior volume [cu.ft.] | 8.7 |
Load per rack [lbs] | 66 |
Net weight of the unit (empty) [lbs] | 445 |
Permitted load [lbs] | 220 |
Wall clearance back [in] | 3.94 |
Wall clearance sidewise [in] | 3.94 |
Environment-specific data | |
Energy consumption at 37 °C and with illumination [Wh/h] | 450 |
Sound-pressure level [dB(A)] | 53 |
Fixtures | |
Number of illumination cassettes (std./max.) | 2/2 |
Number of shelves (std./max.) | 2/7 |
Category | Title | File type / size | Download |
---|---|---|---|
Data Sheets |
KBW 240 |
PDF (95.38 kB) | > |
Operating Manuals |
KBW series |
PDF (8.31 MB) | > |
Technical Drawings |
KBW 240 model External dimensions |
PDF (280.42 kB) | > |
Technical Drawings |
KBW 240 model Access ports |
PDF (162.45 kB) | > |
Technical Drawings |
KBW 240 model Access ports BINDER INDIVIDUAL |
PDF (160.95 kB) | > |
Technical Drawings |
KBW 240 model Interior dimensions |
PDF (170.63 kB) | > |
Case Studies |
Growth chambers (KBW | KBWF series) - Cyanobacteria — Origin of modern life and hope for the future UDE-Aquatische Biotechnologie |
PDF (694.37 kB) | > |
White paper |
Good Laboratory Practice Your checklist for GLP-compliant research and development |
PDF (808.38 kB) | > |
White paper |
Validation and Qualification In the regulated environment |
PDF (392.80 kB) | > |
Brochures |
BINDER Service 100 % performance and availability |
PDF (330.01 kB) | > |
Brochures |
BINDER INDIVIDUAL Series production devices for special requirements |
PDF (712.27 kB) | > |
Brochures |
Growth chambers KBW | KBWF series |
PDF (1.88 MB) | > |