Benefits
Important characteristics
Details of the model
Select version
RRP* [?] | Merken | |
---|---|---|
Model KT 115 | ||
|
- | + |
|
- | + |
Technical data
The PDF data sheet contains technical data, options & accessories as well as services.
Downloads
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
Rated voltage | Option model | Version | Art. No. | RRP* [?] | Selection | Bookmark |
---|---|---|---|---|---|---|
Model KT 115 | ||||||
200…240 V 1~ 50/60 Hz | ||||||
Standard |
KT115-230V | 9020-0313 | - | + | ||
100…120 V 1~ 50/60 Hz | ||||||
Standard |
KT115UL-120V | 9020-0314 | - | + |
Designation | Description | Art. No. | RRP* [?] | Bookmark | ||
---|---|---|---|---|---|---|
Access port with silicone plug | ||||||
right |
8012-1289 | - | + | |||
top |
8012-1152 | - | + | |||
left |
8012-1158 | - | + | |||
top |
8012-1168 | - | + | |||
right |
8012-1155 | - | + | |||
left |
8012-1290 | - | + | |||
top |
8012-1288 | - | + | |||
top |
8012-1161 | - | + | |||
left |
8012-1165 | - | + | |||
right |
8012-1163 | - | + | |||
Alarm output, zero-voltage | ||||||
for temperature (±2 °C), accessible via 6-pin DIN socket (max. 24 V - 2.5 A), with audible signal that can be switched off |
8012-1001 | - | + | |||
Calibration certificate, expanded | ||||||
for temperature; for extending the measurement in center of chamber to include another test temperature |
8012-1122 | - | + | |||
Calibration certificate, temperature | ||||||
for temperature, measurement in center of chamber at specified temperature |
8012-1141 | - | + | |||
temperature measurement incl. certificate, 9 measuring points at specified temperature |
8012-1558 | - | + | |||
temperature measurement incl. certificate and 27 measuring points at specified temperature |
8012-1600 | - | + | |||
temperature measurement incl. certificate, 15- 18 measuring points at specified temperature |
8012-1579 | - | + | |||
Class 3.3 independent temperature safety device | ||||||
with visual alarm (DIN 12880) |
8012-0999 | - | + | |||
Data Logger Kit | ||||||
T 220: For continuous temperature logging from -90 °C to 220 °C. The kit includes 1 data logger, Pt 100 sensor with 2 m extension cable and 1 magnetic fixture for mounting to the BINDER unit |
8012-0715 | - | + | |||
Data Logger Software | ||||||
LOG ANALYZE software kit, configuration and evaluation software for all BINDER Data Logger Kits (incl. USB data cable) |
8012-0821 | - | + | |||
Door heating | ||||||
|
8012-0929 | - | + | |||
|
8012-0928 | - | + | |||
Door lock | ||||||
lockable door handle |
8012-1668 | - | + | |||
Interior lighting | ||||||
with 15 W light bulb |
8012-0933 | - | + | |||
with 15 W light bulb |
8012-0932 | - | + | |||
Interior socket | ||||||
Waterproof, switched flush-mounting box (CA3GD) for nominal voltage in unit interior, with cover and corresponding plug (nominal voltage; max. 500 W; max. 90 °C; protection class IP67) |
8012-1005 | - | + | |||
LED light bars | ||||||
Basic set consisting of 2 pieces, attachment material, control unit for max. 4 light strips, 100-240 V, 50/60 Hz |
8012-1107 | - | + | |||
Basic set consisting of 2 pieces, attachment material, control unit for max. 4 light strips, 100-240 V, 50/60 Hz |
8012-1108 | - | + | |||
Expansion set consisting of 2 pieces, attachment material: clips. For expanding the basic set of light bars |
8012-1716 | - | + | |||
Expansion set consisting of 2 pieces, attachment material: clips. For expanding the basic set of light bars |
8012-1717 | - | + | |||
pH-neutral detergent | ||||||
concentrated, for gentle remove of residual contaminants; 1 kg |
1002-0016 | - | + | |||
Pt 100 temperature sensor | ||||||
additional flexible Pt 100, interior, for displaying the temperature on the unit display |
8012-0993 | - | + | |||
Qualification documents | ||||||
IQ/OQ/PQ documents – supporting documents for validation performed by customers, according to customer requirements, PQ section added to qualification folder IQ/OQ; parameters: temperature, CO₂, O₂ – or pressure, depending on unit |
7007-0005 | - | + | |||
IQ/OQ documents – supporting documents for validation performed by customers, consisting of: IQ/OQ checklists incl. calibration guide and comprehensive unit documentation; parameters: temperature, CO₂, O₂, pressure, depending on unit |
7057-0001 | - | + | |||
IQ/OQ/PQ documents – supporting documents for validation performed by customers, according to customer requirements, PQ section added to qualification folder IQ/OQ; parameters: temperature, CO₂, O₂ – or pressure, depending on unit |
7057-0005 | - | + | |||
IQ/OQ documents – supporting documents for validation performed by customers, consisting of: IQ/OQ checklists incl. calibration guide and comprehensive unit documentation; parameters: temperature, CO₂, O₂, pressure, depending on unit |
7007-0001 | - | + | |||
Rack | ||||||
|
6004-0112 | - | + | |||
Rack accessories | ||||||
fasteners (1 set of 4) for additional security of racks |
8012-0620 | - | + | |||
Rack, reinforced | ||||||
stainless steel, with fasteners (1 set of 4) |
8012-0828 | - | + | |||
Rubber pads | ||||||
set anti-slip feet |
8012-1887 | - | + | |||
Shelf, perforated | ||||||
|
6004-0115 | - | + | |||
Shelf, reinforced | ||||||
positioned at bottom level, max. load 45 kg, with additional attachment for operation of shaking device, stirring device or roller bottle system |
8012-0817 | - | + | |||
Table on castors | ||||||
stable cart, casters with locking brakes, dimensions: W 1,000 x D 800 x H 780 mm |
9051-0018 | - | + | |||
Zero voltage relay contacts | ||||||
for controlling 3 relay contacts via program regulators, accessible via 6-pin DIN socket (max. 24 V - 2.5 A) |
8012-0997 | - | + |
Designation | Description | Art. No. | RRP* [?] | Bookmark | ||
---|---|---|---|---|---|---|
Calibration certificate, temperature |
Calibration of one (1) test temperature specified by the user in center of chamber including certificate |
DL30-0101 | - | + | ||
Calibration certificate, temperature |
Extension of calibration of one (1) additional test temperature specified by the user in the center of the usable space, including certificate |
DL30-0102 | - | + | ||
Execution of IQ/OQ |
Execution of IQ/OQ in accordance with qualification folder |
DL41-0200 | - | + | ||
Execution of IQ/OQ/PQ |
Execution of IQ/OQ/PQ in accordance with qualification folder |
DL44-0500 | - | + | ||
Maintenance |
Maintenance service in accordance with maintenance schedule. Visual inspection of mechanical and electrical components, testing of all key functions. Calibration of a test temperature specified by the user in center of chamber without certificate |
DL20-0200 | - | + | ||
Temperature measurement, 18 measuring points |
Temperature measurement with 18 measuring points with a set value specified by the user, including certificate |
DL30-0118 | - | + | ||
Temperature measurement, 27 measuring points |
Temperature measurement with 27 measuring points with a set value specified by the user, including certificate |
DL30-0127 | - | + | ||
Temperature measurement, 9 measuring points |
Temperature measurement with 9 measuring points with a set value specified by the user, including certificate |
DL30-0109 | - | + | ||
Unit commissioning |
Connect the unit to the customer-side connections (electricity, water, wastewater, gas), basic functions check, brief operating instructions. (excl.: unpacking, setup, controller instructions, programming, installation work) |
DL10-0100 | - | + | ||
Unit instructions |
Instruction regarding operating principle and basic functions of the unit, operation of the control electronics including programming |
DL10-0500 | - | + | ||
Warranty extension from 2 to 3 years |
The warranty is extended from 2 to 3 years from the delivery date, wear parts are excluded |
DL03-0041 | - | + | ||
Warranty extension from 2 to 5 years |
The warranty is extended from 2 to 5 years from the delivery date, wear parts are excluded |
DL03-0042 | - | + |
Designation |
KT115-230V¹ |
KT115UL-120V¹ |
---|---|---|
Option model | Standard | Standard |
Order number | 9020-0313 | 9020-0314 |
Data | ||
Serie | KT | KT |
Performance Data Temperature | ||
Max. heat compensation at 37 °C [W] | 100 | 100 |
Recovery time after 30 seconds door open at 37 °C [min] | 3 | 3 |
Temperature fluctuation [± K] | 0.1 | 0.1 |
Temperature range | 4…100 | 4…100 |
Temperature variation at 37 °C [± K] | 0.3 | 0.3 |
Electrical data | ||
Nominal power [kW] | 0.7 | 0 |
Phase (Nominal voltage) | 1~ | 1~ |
Power frequency [Hz] | 50/60 | 50/60 |
Rated Voltage [V] | 200…240 | 100…120 |
Unit fuse [A] | 10 | 10 |
Doors | ||
Inner doors | 1 | 1 |
Unit doors | 1 | 1 |
Housing dimensions not incl. fittings and connections | ||
Depth net [mm] | 655 | 655 |
Height net [mm] | 715 | 715 |
Width net [mm] | 860 | 860 |
Internal Dimensions | ||
Depth [mm] | 355 | 355 |
Height [mm] | 455 | 455 |
Width [mm] | 600 | 600 |
Measures | ||
Interior volume [L] | 102 | 102 |
Load per rack [kg] | 30 | 30 |
Net weight of the unit (empty) [kg] | 83 | 83 |
Permitted load [kg] | 100 | 100 |
Wall clearance back [mm] | 100 | 100 |
Wall clearance sidewise [mm] | 240 | 240 |
Environment-specific data | ||
Energy consumption at 25 °C [Wh/h] | 75 | 75 |
Energy consumption at 37 °C [Wh/h] | 75 | 75 |
Sound-pressure level [dB(A)] | 48 | 48 |
Fixtures | ||
Number of shelves (std./max.) | 2/6 | 2/6 |
Performance Data Temperature | ||
Max. heat compensation at 37 °C [W] | 100 | 100 |
Recovery time after 30 seconds door open at 37 °C [min] | 3 | 3 |
Temperature fluctuation [± K] | 0.1 | 0.1 |
Temperature range | 4…100 | 4…100 |
Temperature variation at 37 °C [± K] | 0.3 | 0.3 |
Electrical data | ||
Nominal power [kW] | 0.7 | 0 |
Phase (Nominal voltage) | 1~ | 1~ |
Power frequency [Hz] | 50/60 | 50/60 |
Rated Voltage [V] | 200…240 | 100…120 |
Unit fuse [A] | 10 | 10 |
Doors | ||
Inner doors | 1 | 1 |
Unit doors | 1 | 1 |
Housing dimensions not incl. fittings and connections | ||
Depth net [in] | 25.81 | 25.81 |
Height net [in] | 28.17 | 28.17 |
Width net [in] | 33.88 | 33.88 |
Internal Dimensions | ||
Depth [in] | 13.99 | 13.99 |
Height [in] | 17.93 | 17.93 |
Width [in] | 23.64 | 23.64 |
Measures | ||
Interior volume [cu.ft.] | 3.6 | 3.6 |
Load per rack [lbs] | 66 | 66 |
Net weight of the unit (empty) [lbs] | 183 | 183 |
Permitted load [lbs] | 220 | 220 |
Wall clearance back [in] | 3.94 | 3.94 |
Wall clearance sidewise [in] | 9.46 | 9.46 |
Environment-specific data | ||
Energy consumption at 25 °C [Wh/h] | 75 | 75 |
Energy consumption at 37 °C [Wh/h] | 75 | 75 |
Sound-pressure level [dB(A)] | 48 | 48 |
Fixtures | ||
Number of shelves (std./max.) | 2/6 | 2/6 |
Category | Title | File type / size | Download |
---|---|---|---|
Data Sheets |
KT 115 |
PDF (121.50 kB) | > |
Operating Manuals |
KT series |
PDF (10.50 MB) | > |
Case Studies |
Cooling incubators (KB | KT series) - Weleda tests anthroposophic medicine in line with ICH guidelines Weleda AG |
PDF (789.37 kB) | > |
White paper |
Thermoelectric cooling technology Will Peltier modules supersede the compressor? |
PDF (1.27 MB) | > |
White paper |
Validation and Qualification In the regulated environment |
PDF (392.80 kB) | > |
Options & Accessories |
LED light bar sets Series KB | KT | KBF |
PDF (291.69 kB) | > |
Brochures |
BINDER Service 100 % performance and availability |
PDF (330.01 kB) | > |
Brochures |
BINDER INDIVIDUAL Series production devices for special requirements |
PDF (712.27 kB) | > |
Brochures |
Cooling incubators KB | KT series |
PDF (1.95 MB) | > |