Just register your serial number – and enjoy the benefits.
Know-how! Learn how to make optimum use of BINDER technologies to achieve efficient processes.
There for you on-site – all thanks to the global BINDER Service organization.
What's new? Learn more in our news articles.
Simply subscribe and keep up to speed with the BINDER monthly newsletter.
Meet the specialists on simulation chambers. Where? Learn more here.
Do you have any questions or a specific request? Get in touch with us!
Do you have any questions? Here you can find the suitable contact person.
This is how you can find us!
Important characteristics
Details of the model
Select version
RRP* [?] | Merken | |
---|---|---|
Model VD 115 | ||
|
- | + |
|
- | + |
Technical data
The PDF data sheet contains technical data, options & accessories as well as services.
Downloads
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
Rated voltage | Option model | Version | Art. No. | RRP* [?] | Selection | Bookmark |
---|---|---|---|---|---|---|
Model VD 115 | ||||||
230 V 1~ 50/60 Hz | ||||||
Standard |
VD115-230V | 9030-0031 | - | + | ||
120 V 1~ 60 Hz | ||||||
Standard |
VD115UL-120V | 9030-0037 | - | + |
Designation | Description | Art. No. | RRP* [?] | Bookmark | ||
---|---|---|---|---|---|---|
Calibration certificate, expanded | ||||||
for temperature; for extending the measurement in center of chamber to include another test temperature |
8012-1127 | - | + | |||
Calibration certificate, pressure | ||||||
for digital pressure display, measurement at 100 mbar or at specified pressure (range 20 – 900 mbar) |
8012-0440 | - | + | |||
Calibration certificate, temperature | ||||||
for temperature, measurement in center of chamber at specified temperature |
8012-1145 | - | + | |||
temperature measurement incl. certificate, 15- 18 measuring points at specified temperature |
8012-0919 | - | + | |||
temperature measurement incl. certificate, 9 measuring points at specified temperature |
8012-0916 | - | + | |||
Digital pressure display | ||||||
Measuring range from 1 mbar to atmospheric pressure, display accuracy 1 mbar |
8012-0807 | - | + | |||
Door gasket | ||||||
made of FKM, silicone-free |
8012-0502 | - | + | |||
Electric access port | ||||||
9-pin, vacuum-tight access port for transmitting electrical currents, voltages, or signals (max. 50 V / 2 A per pin; vacuum connection DN 16 ISO-KF) |
8012-0262 | - | + | |||
Expansion rack | ||||||
aluminum |
8009-0372 | - | + | |||
stainless steel 1.4571 (V4A) |
8009-0103 | - | + | |||
stainless steel expansion rack instead of standard aluminum expansion rack, incl. calibration |
8012-0618 | - | + | |||
Interface converter | ||||||
RS 422 cable set and RS 232 / RS 422 interface converter for connection to 10-way plug distributor or for connection to a unit |
8012-0557 | - | + | |||
RS 422 cable set and RS 232 / RS 422 interface converter for connection to 10-way plug distributor or for connection to a unit |
8012-0556 | - | + | |||
RS 422 cable set and RS 422 / Ethernet interface converter for connection to 10-way plug distributor or for connection to a unit |
8012-0405 | - | + | |||
RS 422 cable set and RS 422 / Ethernet interface converter for connection to 10-way plug distributor or for connection to a unit |
8012-0380 | - | + | |||
Interface converter, USB / RS422 | ||||||
RS 422 cable set and RS 422 / USB interface converter for connection to 10-way plug distributor or for connection to a unit (USB-powered converter) |
8012-0665 | - | + | |||
pH-neutral detergent | ||||||
concentrated, for gentle remove of residual contaminants; 1 kg |
1002-0016 | - | + | |||
RS 422 interface | ||||||
modular plug distributor for 10 RS 422 interfaces |
8012-0295 | - | + | |||
RS 422 interface, cable (15 m) | ||||||
RS 422 connection cable (15 m) between plug distributor and RS 422 interface |
5023-0036 | - | + | |||
RS 422 interface, cable (50 m) | ||||||
RS 422 extension cable (50 m) between interface converter and unit or RS 232 / RS 422 plug distributor |
5023-0117 | - | + | |||
Temperature measurement of the specimen | ||||||
with flexible Pt 100 sensor and digital specimen temperature display |
8012-0551 | - | + | |||
Vacuum module | ||||||
to receive vacuum pumps, with switchable power socket |
8012-0275 | - | + | |||
to receive vacuum pumps, with switchable power socket |
8012-0132 | - | + | |||
Vacuum module with chemical membrane pump VP 1.1 | ||||||
nominal pumping speed 2.0 m³/h, final pressure 7 mbar, including all necessary parts for vacuum connection, ATEX conformity: II 3G IIC T3 X (only for inner chamber, areas coming in contact with media) |
8012-0738 | - | + | |||
nominal pumping speed 2.0 m³/h, final pressure 7 mbar, including all necessary parts for vacuum connection, ATEX conformity: II 3G IIC T3 X (only for inner chamber, areas coming in contact with media) |
8012-0735 | - | + | |||
Vacuum module with chemical membrane pump VP 2.1 | ||||||
Chemical membrane pump with nominal pumping speed 3.4 m³/h, final pressure 1.5 mbar, ATEX conformity: II 3G IIC T3 X (only for interior, areas coming in contact with media), including all necessary parts for vacuum connection |
8012-0739 | - | + | |||
Chemical membrane pump with nominal pumping speed 3.4 m³/h, final pressure 1.5 mbar, ATEX conformity: II 3G IIC T3 X (only for interior, areas coming in contact with media), including all necessary parts for vacuum connection |
8012-0736 | - | + | |||
Vacuum module with speed-controlled chemical membrane pump VP 3.1 | ||||||
nominal pumping speed 4.6 m³/h, final pressure 1.5 mbar, including all necessary parts for vacuum connection, digital vacuum controller (accurate to ≤1 mbar), ATEX conformity: II 3G IIC T3 X (only for inner chamber, areas coming in contact with media) |
8012-0740 | - | + | |||
nominal pumping speed 4.6 m³/h, final pressure 1.5 mbar, including all necessary parts for vacuum connection, digital vacuum controller (accurate to ≤1 mbar), ATEX conformity: II 3G IIC T3 X (only for inner chamber, areas coming in contact with media) |
8012-0737 | - | + | |||
Vacuum pump connection kit | ||||||
for vacuum pump VP 1.1, VP 2.1, VP 3.1; consisting of aluminum clamping ring, universal centering ring, small flange with hose nozzle, (2.5 m) rubber hose and 2 hose clamps |
8012-0146 | - | + | |||
Vacuum pump VP 1.1 | ||||||
Chemical membrane pump with nominal pumping speed 2.0 m³/h, final pressure 7 mbar, ATEX conformity: II 3G IIC T3 X (only for interior, areas coming in contact with media) |
5013-0118 | - | + | |||
Chemical membrane pump with nominal pumping speed 2.0 m³/h, final pressure 7 mbar, ATEX conformity: II 3G IIC T3 X (only for interior, areas coming in contact with media) |
5013-0117 | - | + | |||
Vacuum pump VP 2.1 | ||||||
chemical membrane pump with nominal pumping speed 3.4 m³/h, final pressure 1.5 mbar, ATEX conformity: II 3G IIC T3 X (only for inner chamber, areas coming in contact with media) |
5013-0120 | - | + | |||
chemical membrane pump with nominal pumping speed 3.4 m³/h, final pressure 1.5 mbar, ATEX conformity: II 3G IIC T3 X (only for inner chamber, areas coming in contact with media) |
5013-0119 | - | + | |||
Vacuum pump VP 3.1 | ||||||
Speed-controlled chemical membrane pump with nominal pumping speed 4.6 m³/h, final pressure 1.5 mbar, ATEX conformity: II 3G IIC T3 X (only for interior, areas coming in contact with media) |
5013-0122 | - | + | |||
Speed-controlled chemical membrane pump with nominal pumping speed 4.6 m³/h, final pressure 1.5 mbar, ATEX conformity: II 3G IIC T3 X (only for interior, areas coming in contact with media) |
5013-0121 | - | + |
Designation | Description | Art. No. | RRP* [?] | Bookmark | ||
---|---|---|---|---|---|---|
Calibration digital pressure display |
including certificate, measurement at specified pressure, range 20 – 900 mbar |
DL32-0000 | - | + | ||
Calibration temperature incl. certificate |
including certificate, one measuring point in center of chamber at specified temperature |
DL30-0101 | - | + | ||
Execution of IQ/OQ |
in accordance with qualification folder |
DL42-0300 | - | + | ||
Execution of IQ/OQ/PQ |
in accordance with customer's requirement, price: on request |
DL44-0500 | - | + | ||
Extension of the warranty from 2 to 3 years |
beginning with the date of delivery, wearing parts are not included |
DL00-8041 | - | + | ||
Extension of the warranty from 2 to 5 years |
beginning with the date of delivery, wearing parts are not included |
DL00-8042 | - | + | ||
Installation |
and set up of unit at operating location, connect to existing connections |
DL10-0100 | - | + | ||
Instruction |
unit function instructions for operation and programming of the controller |
DL10-0500 | - | + | ||
Preventive maintenance |
Executive of equipment inspection according to maintenance plan |
DL20-0400 | - | + | ||
Qualification folder IQ/OQ |
supporting documents for validation performed by customer, consisting of: IQ/OQ checklists, unit schematics, QM certificate in accordance with ISO 9001 |
8012-0859 | - | + | ||
Qualification folder IQ/OQ/PQ |
supporting documents for validation performed by customer, in accordance with customer's requirement, extension of Qualification folder IQ/OQ by chapter PQ |
8012-0948 | - | + | ||
Temperature measurement 15 measuring points |
including certificate, 15 measuring points at specified temperature |
DL30-0218 | - | + | ||
Temperature measurement 9 measuring points |
including certificate, 9 measuring points at specified temperature |
DL30-0109 | - | + |
Designation |
VD115-230V¹ |
VD115UL-120V¹ |
---|---|---|
Option model | Standard | Standard |
Order number | 9030-0031 | 9030-0037 |
Performance Data Temperature | ||
Heating-up time to 100 °C [min] | 95 | 95 |
Temperature fluctuation [± K] | 0.1 | 0.1 |
Temperature range 15 °C above ambient temperature to [°C] | 200 | 200 |
Temperature variation at 100 °C [± K] | 3.5 | 3.5 |
Vacuum Data | ||
Leak rate [bar/h] | 0.01 | 0.01 |
Permitted end vacuum [mbar] | 0.01 | 0.01 |
Electrical data | ||
Nominal power [kW] | 1.7 | 1.7 |
Phase (Nominal voltage) | 1~ | 1~ |
Power frequency [Hz] | 50/60 | 60 |
Rated Voltage [V] | 230 | 120 |
Unit fuse [A] | 10 | 20 |
Connections | ||
Inert gas connection with flow limiter (RP") | 3/8 | 3/8 |
Measuring access port with small flange [DN mm] | 16 | 16 |
Vacuum connection with small flange [DN mm] | 16 | 16 |
Doors | ||
Unit doors | 1 | 1 |
Internal Dimensions | ||
Depth [mm] | 460 | 460 |
Height [mm] | 506 | 506 |
Width [mm] | 506 | 506 |
Measures | ||
Interior volume [L] | 115 | 115 |
Load per rack [kg] | 20 | 20 |
Net weight of the unit (empty) [kg] | 153 | 153 |
permitted load [kg] | 65 | 65 |
Outer dimensions | ||
Depth net [mm] | 670 | 670 |
Height net [mm] | 900 | 900 |
Viewing window height [mm] | 413 | 413 |
Viewing window width [mm] | 456 | 456 |
Wall clearance back [mm] | 100 | 100 |
Wall clearance sidewise [mm] | 135 | 135 |
Width net [mm] | 740 | 740 |
Fixtures | ||
Number of shelves (std./max.) | 2/6 | 2/6 |
Performance Data Temperature | ||
Heating-up time to 100 °C [min] | 95 | 95 |
Temperature fluctuation [± K] | 0.1 | 0.1 |
Temperature range 15 °C above ambient temperature to [°C] | 200 | 200 |
Temperature variation at 100 °C [± K] | 3.5 | 3.5 |
Vacuum Data | ||
Leak rate [bar/h] | 0.01 | 0.01 |
Permitted end vacuum [mbar] | 0.01 | 0.01 |
Electrical data | ||
Nominal power [kW] | 1.7 | 1.7 |
Phase (Nominal voltage) | 1~ | 1~ |
Power frequency [Hz] | 50/60 | 60 |
Rated Voltage [V] | 230 | 120 |
Unit fuse [A] | 10 | 20 |
Connections | ||
Inert gas connection with flow limiter (RP") | 3/8 | 3/8 |
Measuring access port with small flange [DN mm] | 16 | 16 |
Vacuum connection with small flange [DN mm] | 16 | 16 |
Doors | ||
Unit doors | 1 | 1 |
Internal Dimensions | ||
Depth [in] | 18.12 | 18.12 |
Height [in] | 19.94 | 19.94 |
Width [in] | 19.94 | 19.94 |
Measures | ||
Interior volume [cu.ft.] | 4.1 | 4.1 |
Load per rack [lbs] | 44 | 44 |
Net weight of the unit (empty) [lbs] | 337 | 337 |
permitted load [lbs] | 143 | 143 |
Outer dimensions | ||
Depth net [in] | 26.4 | 26.4 |
Height net [in] | 35.46 | 35.46 |
Viewing window height [in] | 16.27 | 16.27 |
Viewing window width [in] | 17.97 | 17.97 |
Wall clearance back [in] | 3.94 | 3.94 |
Wall clearance sidewise [in] | 5.32 | 5.32 |
Width net [in] | 29.16 | 29.16 |
Fixtures | ||
Number of shelves (std./max.) | 2/6 | 2/6 |
Category | Title | File type / size | Download |
---|---|---|---|
Data Sheets |
VD 115 |
PDF (163.72 kB) | > |
Operating Manuals |
Mounting Instructions for Vacuum Module for Vacuum Drying Ovens VD and VDL |
PDF (1.39 MB) | > |
Case Studies |
Good Laboratory Practice Your checklist for GLP-compliant research and development |
PDF (808.38 kB) | > |
Case Studies |
Vacuum drying chambers (Series VD | VDL) - BINDER chambers play a role in smartphone production GEWO Feinmechanik GmbH |
PDF (258.36 kB) | > |
Case Studies |
Vacuum drying chambers (Series VD) | Dynamic climate chambers (Serie MKF) - Material testing TPRC |
PDF (426.63 kB) | > |
Case Studies |
Drying and heating chambers (Series ED | FED) | Vacuum drying chambers (Serie VD) - Cable testing DNV KEMA Energy & Sustainability, KEMA Nederland B.V. |
PDF (537.65 kB) | > |
Brochures |
Vacuum drying chambers VD | VDL series |
PDF (1.73 MB) | > |
Options & Accessories |
Vacuum module with pump VD series |
PDF (112.71 kB) | > |
Buyer´s Guide |
Vacuum drying chambers 4 key factors to consider when buying vacuum drying chambers |
PDF (866.82 kB) | > |