Just register your serial number – and enjoy the benefits.
There for you on-site – all thanks to the global BINDER Service organization.
What's new? Learn more in our news articles.
Simply subscribe and keep up to speed with the BINDER monthly newsletter.
Meet the specialists on simulation chambers. Where? Learn more here.
Do you have any questions or a specific request? Get in touch with us!
Do you have any questions? Here you can find the suitable contact person.
This is how you can find us!
Benefits
Important characteristics
Optional equipment
Details of the model
Select version
Technical data
The PDF data sheet contains technical data, options & accessories as well as services.
Downloads
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
Rated voltage | Option model | Version | Art. No. | Selection | Bookmark | |
---|---|---|---|---|---|---|
Model VD 23 | ||||||
200…230 V 1~ 50/60 Hz | ||||||
Standard |
VD023-230V | 9630-0001 | + | |||
100…120 V 1~ 50/60 Hz | ||||||
Standard |
VD023UL-120V | 9630-0005 | + |
Designation | Description | Art. No. | Bookmark | |||
---|---|---|---|---|---|---|
Additional universal ventilation | ||||||
Additional universal connection for ventilation with ambient air or inert gas. Flow limiter thread (RP"), and connection with 3/8" male thread. |
8612-0001 | + | ||||
Analog output 4-20 mA | ||||||
for temperature and pressure values (output not adjustable) |
8612-0004 | + | ||||
Calibration certificate, expanded | ||||||
for temperature; for extending the measurement in center of chamber to include another test temperature |
8012-1127 | + | ||||
Calibration certificate, pressure | ||||||
Calibration of the pressure display to a specified value, including certificate |
8012-2021 | + | ||||
Extension of the calibration of the pressure display by another pressure value, including certificate |
8012-2022 | + | ||||
Calibration certificate, temperature | ||||||
temperature measurement incl. certificate, 15- 18 measuring points at specified temperature |
8012-0919 | + | ||||
for temperature, measurement in center of chamber at specified temperature |
8012-1145 | + | ||||
temperature measurement incl. certificate, 9 measuring points at specified temperature |
8012-0916 | + | ||||
Door gasket | ||||||
made of FKM, silicone-free |
8612-0007 | + | ||||
Door lock | ||||||
lockable door handle |
8612-0002 | + | ||||
Expansion racks | ||||||
aluminum |
8012-2055 | + | ||||
|
8009-1093 | + | ||||
stainless steel expansion rack instead of standard aluminum expansion rack, incl. calibration |
8612-0011 | + | ||||
Interior lighting | ||||||
LED light strips on the left and right in the door |
8612-0005 | + | ||||
pH-neutral detergent | ||||||
concentrated, for gentle remove of residual contaminants; 1 kg |
1002-0016 | + | ||||
Pump chamber with VAP 1 vacuum pump | ||||||
Pump chamber for vacuum pumps, with switchable power socket. Chemical membrane pump with a nominal air flow of 2.0 m³/hour, final pressure 7 mbar |
8012-1961 | + | ||||
Pump chamber for vacuum pumps, with switchable power socket. Chemical membrane pump with a nominal air flow of 2.0 m³/hour, final pressure 7 mbar |
8012-1958 | + | ||||
Pump chamber with VAP 2 vacuum pump | ||||||
Pump chamber for vacuum pumps, with switchable power socket. Chemical membrane pump with a nominal air flow of 4.0 m³/hour, final pressure 1,8 mbar |
8012-1964 | + | ||||
Pump chamber for vacuum pumps, with switchable power socket. Chemical membrane pump with a nominal air flow of 4.0 m³/hour, final pressure 1,8 mbar |
8012-1967 | + | ||||
Qualification documents | ||||||
IQ/OQ documents – supporting documents for validation performed by customers, consisting of: IQ/OQ checklists incl. calibration guide and comprehensive unit documentation; parameters: temperature, CO₂, O₂, pressure, depending on unit |
7007-0001 | + | ||||
IQ/OQ/PQ documents – supporting documents for validation performed by customers, according to customer requirements, PQ section added to qualification folder IQ/OQ; parameters: temperature, CO₂, O₂ – or pressure, depending on unit |
7057-0005 | + | ||||
IQ/OQ/PQ documents – supporting documents for validation performed by customers, according to customer requirements, PQ section added to qualification folder IQ/OQ; parameters: temperature, CO₂, O₂ – or pressure, depending on unit |
7007-0005 | + | ||||
IQ/OQ documents – supporting documents for validation performed by customers, consisting of: IQ/OQ checklists incl. calibration guide and comprehensive unit documentation; parameters: temperature, CO₂, O₂, pressure, depending on unit |
7057-0001 | + | ||||
Temperature measurement of the specimen | ||||||
with flexible Pt 100 sensor and digital specimen temperature display |
8612-0006 | + | ||||
Touchscreen controller | ||||||
Large display panel with intuitive operation, actual and set values of main process parameters are shown simultaneously on the display. In addition, the graphic chronological evaluation of process parameters is displayed. |
8612-0015 | + | ||||
Universal access port | ||||||
Additional DN 40 small flange universal access port with blind flange, for positioning sensors or supply lines in the chamber. |
8612-0003 | + | ||||
Vacuum pump connection kit | ||||||
for vacuum pump VAP1 and VAP2; consisting of aluminum clamping ring, universal centering ring, small flange with hose nozzle, (2.5 m) rubber hose and 2 hose clamps |
8012-1995 | + | ||||
Vacuum pump VAP 1 | ||||||
Chemical membrane pump with a nominal air flow of 2.0 m³/hour, final pressure 7 mbar |
5013-0217 | + | ||||
Chemical membrane pump with a nominal air flow of 2.0 m³/hour, final pressure 7 mbar |
5013-0223 | + | ||||
Vacuum pump VAP 2 | ||||||
Chemical membrane pump with a nominal air flow of 4.0 m³/hour, final pressure 1,8 mbar |
5013-0219 | + | ||||
Chemical membrane pump with a nominal air flow of 4.0 m³/hour, final pressure 1,8 mbar |
5013-0218 | + | ||||
WLAN kit | ||||||
The kit contains a client bridge that establishes a wireless connection between BINDER units and APT-COM4, LIMS, or customer-specific software via an Ethernet interface. It provides an alternative solution in situations where units need to be positioned in locations without an on-site Ethernet connection. In secured networks, installation and configuration must be performed by the customer’s IT service. |
8500-0164 | + |
Designation | Description | Art. No. | Bookmark | |||
---|---|---|---|---|---|---|
1-year warranty extension |
The warranty is extended by 1 year from the delivery date, wear parts are excluded |
DL50-0020 | + | |||
BRONZE 3-year maintenance contract |
Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts |
DL20-0710 | + | |||
Calibration certificate, temperature |
Extension of calibration of one (1) additional test temperature specified by the user in the center of the usable space, including certificate |
DL30-0102 | + | |||
Calibration certificate, temperature |
Calibration of one (1) test temperature specified by the user in center of chamber, including certificate |
DL30-0101 | + | |||
Execution of IQ/OQ |
Execution of IQ/OQ in accordance with qualification folder |
DL42-0300 | + | |||
Execution of IQ/OQ/PQ |
Execution of IQ/OQ/PQ in accordance with qualification folder |
DL44-0500 | + | |||
GOLD 3-year maintenance contract |
Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts, testing of all key functions, replacement of wear parts, calibration of one temperature/humidity/pressure value, including certificate |
DL20-0930 | + | |||
Maintenance |
One-off maintenance service in accordance with maintenance schedule. Visual inspection of mechanical and electrical components, testing of all key functions. Calibration of a test temperature specified by the user in center of usable space without certificate |
DL20-0400 | + | |||
Pressure calibration |
Digital pressure display calibration at a specified test pressure of 20–900 mbar, including certificate |
DL30-0410 | + | |||
Pressure calibration |
Digital pressure display calibration at a specified test pressure of 20–900 mbar, including certificate |
DL30-0411 | + | |||
SILVER 3-year maintenance contract |
Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts, testing of all key functions, calibration of one test temperature specified by the user in the center of the usable space, without certificate |
DL20-0820 | + | |||
Temperature measurement, 15 measuring points |
Temperature measurement with 15 measuring points with a set value specified by the user, including certificate |
DL30-0218 | + | |||
Temperature measurement, 9 measuring points |
Temperature measurement with 9 measuring points with a set value specified by the user, including certificate |
DL30-0109 | + | |||
Unit commissioning |
Connect the unit to the customer-side connections (electricity, water, wastewater, gas), basic functions check, brief operating instructions. (excl.: unpacking, setup, controller instructions, programming, installation work) |
DL10-0100 | + | |||
Unit instructions |
Instruction regarding operating principle and basic functions of the unit, operation of the control electronics including programming |
DL10-0500 | + | |||
VAP 1 vacuum pump maintenance |
Maintenance service of the VAP 1 vacuum pump according to the maintenance schedule, visual inspection, replacement of the diaphragms, O-rings and seals, (Service Kit 8500-0158 included in the scope of services) as well as final functional test. |
DL20-0410 | + | |||
VAP 2 vacuum pump maintenance |
Maintenance service of the VAP 2 vacuum pump according to the maintenance schedule, visual inspection, replacement of the diaphragms, O-rings and seals, (Service Kit 8500-0159 included in the scope of services) as well as final functional test. |
DL20-0420 | + |
Designation |
VD023-230V¹ |
VD023UL-120V¹ |
---|---|---|
Option model | Standard | Standard |
Order number | 9630-0001 | 9630-0005 |
Data | ||
Serie | VD | VD |
Performance Data Temperature | ||
Heating-up time to 100 °C [min] | 80 | 80 |
Temperature fluctuation [± K] | 0.1 | 0.1 |
Temperature range +10 °C above ambient temperature to [°C] | 220 | 220 |
Temperature range +9 °C above ambient temperature to [°C] | 220 | 220 |
Temperature variation at 100 °C [± K] | 1.0 | 1.0 |
Vacuum Data | ||
Leak rate [bar/h] | 0.01 | 0.01 |
Electrical data | ||
Nominal power [kW] | 0.9 | 0.9 |
Phase (Nominal voltage) | 1~ | 1~ |
Power frequency [Hz] | 50/60 | 50/60 |
Rated Voltage [V] | 200…230 | 100…120 |
Unit fuse [A] | 6.3 | 10 |
Connections | ||
Compressed air connection for pressure-encapsulation [NW] | 5 | 5 |
Measuring access port with small flange [DN mm] | 16 | 16 |
Universal connection for air / inert gas with flow limiter thread (RP") 3/8 | 3/8 | 3/8 |
Vacuum connection with small flange [DN mm] | 16 | 16 |
Doors | ||
Unit doors | 1 | 1 |
Housing dimensions not incl. fittings and connections | ||
Depth net [mm] | 413 | 413 |
Height net [mm] | 698 | 698 |
Width net [mm] | 523 | 523 |
Internal Dimensions | ||
Depth [mm] | 295 | 295 |
Height [mm] | 285 | 285 |
Width [mm] | 285 | 285 |
Measures | ||
Interior volume [L] | 24 | 24 |
Load per rack [kg] | 20 | 20 |
Net weight of the unit (empty) [kg] | 64 | 68 |
Permitted load [kg] | 50 | 50 |
Viewing window height [mm] | 305 | 305 |
Viewing window width [mm] | 305 | 305 |
Wall clearance back [mm] | 100 | 100 |
Wall clearance sidewise [mm] | 70 | 70 |
Environment-specific data | ||
Sound-pressure level [dB(A)] | 40 | 40 |
Fixtures | ||
Number of shelves (std./max.) | 1/4 | 1/4 |
Performance Data Temperature | ||
Heating-up time to 100 °C [min] | 80 | 80 |
Temperature fluctuation [± K] | 0.1 | 0.1 |
Temperature range +10 °C above ambient temperature to [°C] | 220 | 220 |
Temperature range +9 °C above ambient temperature to [°C] | 220 | 220 |
Temperature variation at 100 °C [± K] | 1 | 1 |
Vacuum Data | ||
Leak rate [bar/h] | 0.01 | 0.01 |
Electrical data | ||
Nominal power [kW] | 0.9 | 0.9 |
Phase (Nominal voltage) | 1~ | 1~ |
Power frequency [Hz] | 50/60 | 50/60 |
Rated Voltage [V] | 200…230 | 100…120 |
Unit fuse [A] | 6.3 | 10 |
Connections | ||
Compressed air connection for pressure-encapsulation [NW] | 5 | 5 |
Measuring access port with small flange [DN mm] | 16 | 16 |
Universal connection for air / inert gas with flow limiter thread (RP") 3/8 | 3/8 | 3/8 |
Vacuum connection with small flange [DN mm] | 16 | 16 |
Doors | ||
Unit doors | 1 | 1 |
Housing dimensions not incl. fittings and connections | ||
Depth net [in] | 16.27 | 16.27 |
Height net [in] | 27.5 | 27.5 |
Width net [in] | 20.61 | 20.61 |
Internal Dimensions | ||
Depth [in] | 11.62 | 11.62 |
Height [in] | 11.23 | 11.23 |
Width [in] | 11.23 | 11.23 |
Measures | ||
Interior volume [cu.ft.] | 0.8 | 0.8 |
Load per rack [lbs] | 44 | 44 |
Net weight of the unit (empty) [lbs] | 141 | 150 |
Permitted load [lbs] | 110 | 110 |
Viewing window height [in] | 12.02 | 12.02 |
Viewing window width [in] | 12.02 | 12.02 |
Wall clearance back [in] | 3.94 | 3.94 |
Wall clearance sidewise [in] | 2.76 | 2.76 |
Environment-specific data | ||
Sound-pressure level [dB(A)] | 40 | 40 |
Fixtures | ||
Number of shelves (std./max.) | 1/4 | 1/4 |
Category | Title | File type / size | Download |
---|---|---|---|
Data Sheets |
VD 23 |
PDF (138.62 kB) | > |
Operating Manuals |
VD series |
PDF (10.20 MB) | > |
Operating Manuals |
Vacuum pump VAP1 | VAP2 For vacuum drying oven VD |
PDF (4.05 MB) | > |
Technical Drawings |
Version VD023-230V |
PDF (255.73 kB) | > |
Technical Drawings |
Version VD023-120V |
PDF (249.94 kB) | > |
Technical Drawings |
Vacuum pump VAP 2 5013-0218 |
PDF (216.25 kB) | > |
Technical Drawings |
Vacuum pump VAP 1 5013-0217 |
PDF (200.62 kB) | > |
Case Studies |
Vacuum drying chambers (VD | VDL series) - BINDER chambers play a role in smartphone production GEWO Feinmechanik GmbH |
PDF (258.36 kB) | > |
Case Studies |
Vacuum drying chambers (VD series) - Vacuum drying chambers used to dry jewelry gently Schofer Pforzheim |
PDF (214.90 kB) | > |
Case Studies |
Vacuum drying chambers (VD | VDL series) - How Aesculap uses BINDER chambers for quality testing B | Braun Aesculap AG |
PDF (180.57 kB) | > |
Case Studies |
Drying and heating chambers (FP series) - Drying chambers, constant climate chambers, dynamic climate chambers and cooling incubators test the service life of MinebeaMitsumi spindle motors MinebeaMitsumi Technology Center Europe GmbH |
PDF (479.77 kB) | > |
White paper |
Good Laboratory Practice Your checklist for GLP-compliant research and development |
PDF (808.38 kB) | > |
White paper |
Validation and Qualification In the regulated environment |
PDF (392.80 kB) | > |
Brochures |
BINDER INDIVIDUAL Series production devices for special requirements |
PDF (712.27 kB) | > |
Brochures |
Vacuum drying chambers VD | VDL series |
PDF (1.38 MB) | > |
Buyer´s Guide |
Vacuum drying chambers 4 key factors to consider when buying vacuum drying chambers |
PDF (1.97 MB) | > |