Just register your serial number – and enjoy the benefits.
Know-how! Learn how to make optimum use of BINDER technologies to achieve efficient processes.
There for you on-site – all thanks to the global BINDER Service organization.
What's new? Learn more in our news articles.
Simply subscribe and keep up to speed with the BINDER monthly newsletter.
Meet the specialists on simulation chambers. Where? Learn more here.
Do you have any questions or a specific request? Get in touch with us!
Do you have any questions? Here you can find the suitable contact person.
This is how you can find us!
Benefits
Important characteristics
Details of the model
Select version
RRP* [?] | Merken | |
---|---|---|
Model FED 115 | ||
|
- | + |
|
- | + |
Technical data
The PDF data sheet contains technical data, options & accessories as well as services.
Downloads
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
Rated voltage | Option model | Version | Art. No. | RRP* [?] | Selection | Bookmark |
---|---|---|---|---|---|---|
Model FED 115 | ||||||
230 V 1~ 50/60 Hz | ||||||
Standard |
FED115-230V | 9010-0293 | - | + | ||
120 V 1~ 60 Hz | ||||||
Standard |
FED115UL-120V | 9010-0294 | - | + |
Designation | Description | Art. No. | RRP* [?] | Bookmark | ||
---|---|---|---|---|---|---|
Access port with silicone plug | ||||||
left |
8012-1669 | - | + | |||
top |
8012-1381 | - | + | |||
top |
8012-1365 | - | + | |||
top |
8012-1264 | - | + | |||
left |
8012-1655 | - | + | |||
left |
8012-1278 | - | + | |||
top |
8012-1672 | - | + | |||
left |
8012-1657 | - | + | |||
right |
8012-1654 | - | + | |||
right |
8012-1670 | - | + | |||
right |
8012-1271 | - | + | |||
right |
8012-1656 | - | + | |||
Alarm function for overheating | ||||||
Switchable acoustic alarm, with adjustable limit value on the independent temperature safety device |
8012-1637 | - | + | |||
Analog output 4-20 mA | ||||||
for temperature values (output not adjustable) |
8012-1625 | - | + | |||
Calibration certificate, expanded | ||||||
for temperature; for extending the measurement in center of chamber to include another test temperature |
8012-1118 | - | + | |||
Calibration certificate, temperature | ||||||
for temperature, measurement in center of chamber at specified temperature |
8012-1137 | - | + | |||
temperature measurement incl. certificate, 9 measuring points at specified temperature |
8012-1554 | - | + | |||
temperature measurement incl. certificate and 27 measuring points at specified temperature |
8012-1596 | - | + | |||
temperature measurement incl. certificate, 15- 18 measuring points at specified temperature |
8012-1575 | - | + | |||
Class 3.1 independent temperature safety device | ||||||
with visual alarm (DIN 12880) |
8012-1644 | - | + | |||
Clock | ||||||
battery-backed |
8012-1642 | - | + | |||
Data Logger Kit | ||||||
T 350: For continuous temperature logging from 0 °C to 350 °C; kit includes 1 data logger, Pt 100 sensor with 2 m extension cable and 1 magnetic fixture for mounting to the BINDER unit |
8012-0714 | - | + | |||
Data Logger Software | ||||||
LOG ANALYZE software kit, configuration and evaluation software for all BINDER Data Logger Kits (incl. USB data cable) |
8012-0821 | - | + | |||
Door gasket | ||||||
made of FKM, silicone-free |
8012-1651 | - | + | |||
Door lock | ||||||
lockable door handle |
8012-1666 | - | + | |||
Gas-tight option model | ||||||
Incl. additional measures for the greatest possible impermeability to gas; not in conjunction with access port or interior lighting option |
8012-1686 | - | + | |||
Heating output, reinforced | ||||||
for faster heating up time and improved recovery time; max. 300 °C |
8012-1699 | - | + | |||
HEPA air filter | ||||||
On fresh air supply for unit; filter classification H14 (acc. to. EN 1822-1:2009, > 99.995% at 0.3 µm) |
8012-1696 | - | + | |||
Inert gas connection | ||||||
With gas inlet and outlet, Ø 10 mm, incl. additional measures for the greatest possible impermeability to gas; not in conjunction with access port or interior lighting option |
8012-1692 | - | + | |||
Inner chamber, reinforced | ||||||
max. total load 170 kg |
8012-1714 | - | + | |||
Interior lighting | ||||||
with 15 W light bulb |
8012-1629 | - | + | |||
with 15 W light bulb |
8012-1633 | - | + | |||
Measurement of air exchange rate | ||||||
in accordance with ASTM D5374, definition and protocol according to ambient temperature |
8012-1197 | - | + | |||
pH-neutral detergent | ||||||
concentrated, for gentle remove of residual contaminants; 1 kg |
1002-0016 | - | + | |||
Pt 100 temperature sensor | ||||||
additional flexible Pt 100, interior, for displaying the temperature on the unit display |
8012-1621 | - | + | |||
Qualification documents | ||||||
IQ/OQ/PQ documents – supporting documents for validation performed by customers, according to customer requirements, PQ section added to qualification folder IQ/OQ; parameters: temperature, CO₂, O₂ – or pressure, depending on unit |
7007-0005 | - | + | |||
IQ/OQ documents – supporting documents for validation performed by customers, consisting of: IQ/OQ checklists incl. calibration guide and comprehensive unit documentation; parameters: temperature, CO₂, O₂, pressure, depending on unit |
7057-0001 | - | + | |||
IQ/OQ/PQ documents – supporting documents for validation performed by customers, according to customer requirements, PQ section added to qualification folder IQ/OQ; parameters: temperature, CO₂, O₂ – or pressure, depending on unit |
7057-0005 | - | + | |||
IQ/OQ documents – supporting documents for validation performed by customers, consisting of: IQ/OQ checklists incl. calibration guide and comprehensive unit documentation; parameters: temperature, CO₂, O₂, pressure, depending on unit |
7007-0001 | - | + | |||
Rack | ||||||
|
6004-0167 | - | + | |||
|
6004-0151 | - | + | |||
Rack, heavy load | ||||||
Stainless steel, max. load per rack 70 kg |
6004-0250 | - | + | |||
Rubber pads | ||||||
set anti-slip feet |
8012-1887 | - | + | |||
Shelf, perforated | ||||||
|
6004-0183 | - | + | |||
Table on castors | ||||||
stable cart, casters with locking brakes, dimensions: W 1,000 x D 800 x H 780 mm |
9051-0018 | - | + | |||
Viewing window and interior lighting | ||||||
viewing window (triple insulating glass) in door, 370 x 370 mm, and 15 W interior |
8012-1705 | - | + | |||
viewing window (triple insulating glass) in door, 370 x 370 mm, and 15 W interior |
8012-1707 | - | + |
Designation | Description | Art. No. | RRP* [?] | Bookmark | ||
---|---|---|---|---|---|---|
1-year warranty extension |
The warranty is extended by 1 year from the delivery date, wear parts are excluded |
DL50-0010 | - | + | ||
BRONZE 3-year maintenance contract |
Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts |
DL20-0710 | - | + | ||
Calibration certificate, temperature |
Calibration of one (1) test temperature specified by the user in center of chamber including certificate |
DL30-0101 | - | + | ||
Calibration certificate, temperature |
Extension of calibration of one (1) additional test temperature specified by the user in the center of the usable space, including certificate |
DL30-0102 | - | + | ||
Execution of IQ/OQ |
Execution of IQ/OQ in accordance with qualification folder |
DL40-0100 | - | + | ||
Execution of IQ/OQ/PQ |
Execution of IQ/OQ/PQ in accordance with qualification folder |
DL44-0500 | - | + | ||
GOLD 3-year maintenance contract |
Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts, testing of all key functions, replacement of wear parts, calibration of one test temperature specified by the user in the center of the usable space, including certificate |
DL20-0910 | - | + | ||
Maintenance |
One-off maintenance service in accordance with maintenance schedule. Visual inspection of mechanical and electrical components, testing of all key functions. Calibration of a test temperature specified by the user in center of usable space without certificate |
DL20-0200 | - | + | ||
Measurement of air exchange rate |
including certificate (in accordance with ASTM D5374) |
DL33-0000 | - | + | ||
SILVER 3-year maintenance contract |
Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts, testing of all key functions, calibration of one test temperature specified by the user in the center of the usable space, without certificate |
DL20-0810 | - | + | ||
Temperature measurement, 18 measuring points |
Temperature measurement with 18 measuring points with a set value specified by the user, including certificate |
DL30-0118 | - | + | ||
Temperature measurement, 27 measuring points |
Temperature measurement with 27 measuring points with a set value specified by the user, including certificate |
DL30-0127 | - | + | ||
Temperature measurement, 9 measuring points |
Temperature measurement with 9 measuring points with a set value specified by the user, including certificate |
DL30-0109 | - | + | ||
Unit commissioning |
Connect the unit to the customer-side connections (electricity, water, wastewater, gas), basic functions check, brief operating instructions. (excl.: unpacking, setup, controller instructions, programming, installation work) |
DL10-0100 | - | + | ||
Unit instructions |
Instruction regarding operating principle and basic functions of the unit, operation of the control electronics including programming |
DL10-0500 | - | + |
Designation |
FED115-230V¹ |
FED115UL-120V¹ |
---|---|---|
Option model | Standard | Standard |
Order number | 9010-0293 | 9010-0294 |
Data | ||
Serie | FED | FED |
Performance Data Temperature | ||
Heating-up time to 150 °C [min] | 18 | 18 |
Recovery time after 30 seconds door open at 150 °C [min] | 4 | 4 |
Temperature fluctuation at 150 °C [± K] | 0.3 | 0.3 |
Temperature range +10 °C above ambient temperature to [°C] | 300 | 300 |
Temperature variation at 150 °C [± K] | 1.2 | 1.2 |
Air change data | ||
Air change (approx.) at 100 °C [x/h] | 32 | 32 |
Electrical data | ||
Nominal power [kW] | 1.3 | 1.4 |
Phase (Nominal voltage) | 1~ | 1~ |
Power frequency [Hz] | 50/60 | 60 |
Rated Voltage [V] | 230 | 120 |
Unit fuse [A] | 6.3 | 12.5 |
Doors | ||
Unit doors | 1 | 1 |
Housing dimensions not incl. fittings and connections | ||
Depth net [mm] | 605 | 605 |
Height net [mm] | 705 | 705 |
Width net [mm] | 710 | 710 |
Internal Dimensions | ||
Depth [mm] | 385 | 385 |
Height [mm] | 550 | 550 |
Width [mm] | 550 | 550 |
Measures | ||
Interior volume [L] | 116 | 116 |
Load per rack [kg] | 30 | 30 |
Net weight of the unit (empty) [kg] | 57 | 57 |
Permitted load [kg] | 150 | 150 |
Wall clearance back [mm] | 160 | 160 |
Wall clearance sidewise [mm] | 100 | 100 |
Environment-specific data | ||
Energy consumption at 150 °C [Wh/h] | 340 | 340 |
Sound-pressure level [dB(A)] | 43 | 43 |
Fixtures | ||
Number of shelves (std./max.) | 2/5 | 2/5 |
Performance Data Temperature | ||
Heating-up time to 150 °C [min] | 18 | 18 |
Recovery time after 30 seconds door open at 150 °C [min] | 4 | 4 |
Temperature fluctuation at 150 °C [± K] | 0.3 | 0.3 |
Temperature range +10 °C above ambient temperature to [°C] | 300 | 300 |
Temperature variation at 150 °C [± K] | 1.2 | 1.2 |
Air change data | ||
Air change (approx.) at 100 °C [x/h] | 32 | 32 |
Electrical data | ||
Nominal power [kW] | 1.3 | 1.4 |
Phase (Nominal voltage) | 1~ | 1~ |
Power frequency [Hz] | 50/60 | 60 |
Rated Voltage [V] | 230 | 120 |
Unit fuse [A] | 6.3 | 12.5 |
Doors | ||
Unit doors | 1 | 1 |
Housing dimensions not incl. fittings and connections | ||
Depth net [in] | 23.84 | 23.84 |
Height net [in] | 27.78 | 27.78 |
Width net [in] | 27.97 | 27.97 |
Internal Dimensions | ||
Depth [in] | 15.17 | 15.17 |
Height [in] | 21.67 | 21.67 |
Width [in] | 21.67 | 21.67 |
Measures | ||
Interior volume [cu.ft.] | 4.1 | 4.1 |
Load per rack [lbs] | 66 | 66 |
Net weight of the unit (empty) [lbs] | 126 | 126 |
Permitted load [lbs] | 331 | 331 |
Wall clearance back [in] | 6.3 | 6.3 |
Wall clearance sidewise [in] | 3.94 | 3.94 |
Environment-specific data | ||
Energy consumption at 150 °C [Wh/h] | 340 | 340 |
Sound-pressure level [dB(A)] | 43 | 43 |
Fixtures | ||
Number of shelves (std./max.) | 2/5 | 2/5 |
Category | Title | File type / size | Download |
---|---|---|---|
Data Sheets |
FED 115 |
PDF (94.51 kB) | > |
Operating Manuals |
Quick Start Guide BD | BF | ED | FD | FED series |
PDF (1.53 MB) | > |
Operating Manuals |
BD | BF | ED | FD | FED series Avantgarde.Line Models 56 | 115 | 260 | 720 |
PDF (10.79 MB) | > |
Technical Drawings |
Model FED 115 Interior dimensions |
PDF (288.85 kB) | > |
Technical Drawings |
Model FED 115 External dimensions |
PDF (160.32 kB) | > |
Technical Drawings |
Model FED 115 Access ports |
PDF (104.75 kB) | > |
Technical Drawings |
Model FED 115 Access ports BINDER INDIVIDUAL |
PDF (92.36 kB) | > |
Case Studies |
Drying and heating chambers (ED | FED series) - Carbon frames for racing bikes SWT Swiss Manufacturing Technology AG, BMC Swiss Cycling Technologie |
PDF (1.90 MB) | > |
White paper |
Good Laboratory Practice Your checklist for GLP-compliant research and development |
PDF (808.38 kB) | > |
White paper |
Artificial aging Predicting material behavior |
PDF (435.64 kB) | > |
White paper |
Validation and Qualification In the regulated environment |
PDF (392.80 kB) | > |
Brochures |
Drying and heating chambers E | ED | ED-S | FD | FD-S | FED | FP | M series |
PDF (2.98 MB) | > |
Brochures |
BINDER Service 100 % performance and availability |
PDF (330.01 kB) | > |
Brochures |
BINDER INDIVIDUAL Series production devices for special requirements |
PDF (712.27 kB) | > |