Series ED Classic.Line | Drying and heating chambers with natural convection

The strengths of a BINDER ED series drying chamber include routine drying and sterilization tasks up to +300 °C. Thanks to the natural convection, all thermal processes which use this drying chamber are highly efficient. The ED series ensures fast, uniform drying.

Benefits

  • Uniform drying conditions thanks to APT.line™ technology
  • Identical test conditions throughout the chamber interior independent of sample size and quantity
  • Outstanding thermal insulation saves operation costs

Important characteristics

  • Temperature range: +5 °C above ambient temperature to +300 °C
  • APT.line™ preheating chamber technology
  • Natural convection
  • Adjustable exhaust air flap
  • Controller with timer functions
  • 2 chrome-plated racks
  • Class 2 independent adjustable temperature safety device (DIN 12880) with visual alarm
Models
  • Model ED 23
  • Housing dimensions not incl. fittings and connections - W x H x D [mm]: 435 x 495 x 520
  • Internal dimension W x H x D [mm]: 222 x 330 x 300
  • Net weight [kg]: 27
  • Interior volume [L]: 20
  • Bookmark +
  • Model ED 400
  • Housing dimensions not incl. fittings and connections - W x H x D [mm]: 1235 x 1025 x 765
  • Internal dimension W x H x D [mm]: 1000 x 800 x 520
  • Net weight [kg]: 125
  • Interior volume [L]: 400
  • Bookmark +
Technical data

Please select a model to view technical data:

Services
RRP* [?] Merken
  • Designation:

    Calibration certificate, temperature

  • Description:

    Extension of calibration of one (1) additional test temperature specified by the user in the center of the usable space, including certificate

  • Art. No.: DL30-0102
- +
  • Designation:

    Calibration certificate, temperature

  • Description:

    Calibration of one (1) test temperature specified by the user in center of chamber including certificate

  • Art. No.: DL30-0101
- +
  • Designation:

    Execution of IQ/OQ

  • Description:

    Execution of IQ/OQ in accordance with qualification folder

  • Art. No.: DL40-0100
- +
  • Designation:

    Execution of IQ/OQ/PQ

  • Description:

    Execution of IQ/OQ/PQ in accordance with qualification folder

  • Art. No.: DL44-0500
- +
  • Designation:

    Maintenance

  • Description:

    Maintenance service in accordance with maintenance schedule. Visual inspection of mechanical and electrical components, testing of all key functions. Calibration of a test temperature specified by the user in center of chamber without certificate

  • Art. No.: DL20-0200
- +
  • Designation:

    Measurement of air exchange rate

  • Description:

    including certificate (in accordance with ASTM D5374)

  • Art. No.: DL33-0000
- +
  • Designation:

    Temperature measurement, 18 measuring points

  • Description:

    Temperature measurement with 18 measuring points with a set value specified by the user, including certificate

  • Art. No.: DL30-0118
- +
  • Designation:

    Temperature measurement, 27 measuring points

  • Description:

    Temperature measurement with 27 measuring points with a set value specified by the user, including certificate

  • Art. No.: DL30-0127
- +
  • Designation:

    Temperature measurement, 9 measuring points

  • Description:

    Temperature measurement with 9 measuring points with a set value specified by the user, including certificate

  • Art. No.: DL30-0109
- +
  • Designation:

    Unit commissioning

  • Description:

    Connect the unit to the customer-side connections (electricity, water, wastewater, gas), basic functions check, brief operating instructions. (excl.: unpacking, setup, controller instructions, programming, installation work)

  • Art. No.: DL10-0100
- +
  • Designation:

    Unit instructions

  • Description:

    Instruction regarding operating principle and basic functions of the unit, operation of the control electronics including programming

  • Art. No.: DL10-0500
- +
  • Designation:

    Warranty extension from 2 to 3 years

  • Description:

    The warranty is extended from 2 to 3 years from the delivery date, wear parts are excluded

  • Art. No.: DL00-2041
- +
  • Designation:

    Warranty extension from 2 to 5 years

  • Description:

    The warranty is extended from 2 to 5 years from the delivery date, wear parts are excluded

  • Art. No.: DL00-2042
- +
Options and Accessories

Complementary to our products we offer a broad range of options and accessories - from access ports and to racks to documentation and software.

Please select a model to get an overview of all available options and accessories for this product:

Downloads

BD | ED | FD series Classic.Line

  • Category: Operating Manuals
  • File type / size PDF (8.96 MB)

Drying and heating chambers (FP series) - Drying chambers, constant climate chambers, dynamic climate chambers and cooling incubators test the service life of MinebeaMitsumi spindle motors MinebeaMitsumi Technology Center Europe GmbH

  • Category: Case Studies
  • File type / size PDF (479.77 kB)

Good Laboratory Practice Your checklist for GLP-compliant research and development

  • Category: White paper
  • File type / size PDF (808.38 kB)

Artificial aging Predicting material behavior

  • Category: White paper
  • File type / size PDF (435.64 kB)

Validation and Qualification In the regulated environment

  • Category: White paper
  • File type / size PDF (392.80 kB)

Drying and heating chambers E | ED | ED-S | FD | FD-S | FED | FP | M series

  • Category: Brochures
  • File type / size PDF (2.98 MB)

BINDER Service 100 % performance and availability

  • Category: Brochures
  • File type / size PDF (330.01 kB)

BINDER INDIVIDUAL Series production devices for special requirements

  • Category: Brochures
  • File type / size PDF (712.27 kB)