Benefits
Important characteristics
Optional equipment
Details of the model
Select version
RRP* [?] | Merken | |
---|---|---|
Model CB-S 260 | ||
|
- | + |
|
- | + |
Technical data
The PDF data sheet contains technical data, options & accessories as well as services.
Downloads
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
Rated voltage | Option model | Version | Art. No. | RRP* [?] | Selection | Bookmark |
---|---|---|---|---|---|---|
Model CB-S 260 | ||||||
200…230 V 1~ 50/60 Hz | ||||||
Standard |
CBS260-230V | 9040-0191 | - | + | ||
100…120 V 1~ 50/60 Hz | ||||||
Standard |
CBS260UL-120V | 9040-0192 | - | + |
Designation | Description | Art. No. | RRP* [?] | Bookmark | ||
---|---|---|---|---|---|---|
Access port with silicone plug | ||||||
right |
8012-1976 | - | + | |||
back |
8012-1974 | - | + | |||
left |
8012-1975 | - | + | |||
Analog output 4-20 mA | ||||||
for temperature and CO₂ values (outputs not adjustable) |
8012-1977 | - | + | |||
Base | ||||||
the base equipped with casters is used for the secure positioning and leveling of a BINDER CO₂ incubator |
9051-0044 | - | + | |||
Calibration certificate, expanded | ||||||
for temperature; for extending the measurement in center of chamber to include another test temperature |
8012-1112 | - | + | |||
Calibration certificate, temperature | ||||||
temperature measurement incl. certificate, 15- 18 measuring points at specified temperature |
8012-1570 | - | + | |||
for temperature, measurement in center of chamber at specified temperature |
8012-1131 | - | + | |||
temperature measurement incl. certificate and 27 measuring points at specified temperature |
8012-1591 | - | + | |||
temperature measurement incl. certificate, 9 measuring points at specified temperature |
8012-1549 | - | + | |||
Calibration certificate, temperature and CO₂ | ||||||
for temperature and CO₂, temperature measurement in center of chamber, CO₂ measurement performed using test gas at 37 °C and 5 % CO₂ |
8012-0228 | - | + | |||
Cleaning kit | ||||||
for equipment maintenance and disinfection, consisting of pH-neutral detergent (1000 g, concentrate), spray disinfectant (500 ml, ready-to-use solution), lint-free cleansing tissues, protective gloves, and protective glasses |
8012-0503 | - | + | |||
Door hinged on the left | ||||||
Unit door and standard glass inner door with door hinged on the left |
8012-1993 | - | + | |||
Door lock | ||||||
lockable door handle |
8012-1014 | - | + | |||
Gas cylinder connection set | ||||||
for N₂, consisting of a gas tank pressure regulator with connection parts and 5-meter hose |
8012-0016 | - | + | |||
for O₂, consisting of a gas tank pressure regulator with connection parts and 5-meter hose |
8012-0015 | - | + | |||
for CO₂, consisting of a gas tank pressure regulator with connection parts and 5-meter hose |
8012-0014 | - | + | |||
Gas tank changer | ||||||
external, BINDER Gas Supply Service, for connecting 2 gas tanks (CO₂, N₂ or O₂), with audible and visual alarms, as well as zero-voltage alarm output |
8012-0408 | - | + | |||
pH-neutral detergent | ||||||
concentrated, for gentle remove of residual contaminants; 1 kg |
1002-0016 | - | + | |||
Qualification documents | ||||||
IQ/OQ documents – supporting documents for validation performed by customers, consisting of: IQ/OQ checklists incl. calibration guide and comprehensive unit documentation; parameters: temperature, CO₂, O₂, pressure, depending on unit |
7007-0001 | - | + | |||
IQ/OQ/PQ documents – supporting documents for validation performed by customers, according to customer requirements, PQ section added to qualification folder IQ/OQ; parameters: temperature, CO₂, O₂ – or pressure, depending on unit |
7057-0005 | - | + | |||
IQ/OQ documents – supporting documents for validation performed by customers, consisting of: IQ/OQ checklists incl. calibration guide and comprehensive unit documentation; parameters: temperature, CO₂, O₂, pressure, depending on unit |
7057-0001 | - | + | |||
IQ/OQ/PQ documents – supporting documents for validation performed by customers, according to customer requirements, PQ section added to qualification folder IQ/OQ; parameters: temperature, CO₂, O₂ – or pressure, depending on unit |
7007-0005 | - | + | |||
Rubber pads | ||||||
set anti-slip feet |
8012-0702 | - | + | |||
Shaker „Professional“ | ||||||
Shaker and controller equipped with LEMO connectors, exclusively for CB with electric access port, 100 – 240 V, 50/60 Hz |
8012-1772 | - | + | |||
Shaker „Universal“ | ||||||
Shaker and controller connected via ribbon cable, universally applicable, 100 – 240 V, 50/60 Hz |
8012-1771 | - | + | |||
Shelf, perforated | ||||||
|
6004-0197 | - | + | |||
for divided inner door |
8012-1996 | - | + | |||
Stacking adapter | ||||||
for the thermally isolated stacking of two BINDER CO₂ incubators |
9051-0039 | - | + | |||
Stacking frame | ||||||
stable, vibration-free stacking frame on casters with stop brake for safe stacking of two CB series units |
9051-0041 | - | + | |||
stable, vibration-free stacking frame on casters with stop brake for safe stacking of two CB series units |
9051-0040 | - | + |
Designation | Description | Art. No. | RRP* [?] | Bookmark | ||
---|---|---|---|---|---|---|
1-year warranty extension |
The warranty is extended by 1 year from the delivery date, wear parts are excluded |
DL50-0020 | - | + | ||
BRONZE 3-year maintenance contract |
Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts |
DL20-0710 | - | + | ||
Calibration certificate, temperature |
Extension of calibration of one (1) additional test temperature specified by the user in the center of the usable space, including certificate |
DL30-0102 | - | + | ||
Calibration certificate, temperature |
Calibration of one (1) test temperature specified by the user in center of chamber including certificate |
DL30-0101 | - | + | ||
CO₂ calibration |
CO₂ calibration at a specified value, measurements are taken with analyzed test gas at 5%, including certificate |
DL30-0401 | - | + | ||
Execution of IQ/OQ |
Execution of IQ/OQ in accordance with qualification folder |
DL41-0200 | - | + | ||
Execution of IQ/OQ/PQ |
Execution of IQ/OQ/PQ in accordance with qualification folder |
DL44-0500 | - | + | ||
GOLD 3-year maintenance contract |
Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts, testing of all key functions, replacement of wear parts, calibration of one temperature and CO₂ value, including certificate |
DL20-0940 | - | + | ||
Maintenance |
One-off maintenance service in accordance with maintenance schedule. Visual inspection of mechanical and electrical components, testing of all key functions. Calibration of a test temperature specified by the user in center of usable space without certificate |
DL20-0400 | - | + | ||
SILVER 3-year maintenance contract |
Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts, testing of all key functions, calibration of one test temperature specified by the user in the center of the usable space, without certificate |
DL20-0820 | - | + | ||
Temperature measurement, 18 measuring points |
Temperature measurement with 18 measuring points with a set value specified by the user, including certificate |
DL30-0118 | - | + | ||
Temperature measurement, 27 measuring points |
Temperature measurement with 27 measuring points with a set value specified by the user, including certificate |
DL30-0127 | - | + | ||
Temperature measurement, 9 measuring points |
Temperature measurement with 9 measuring points with a set value specified by the user, including certificate |
DL30-0109 | - | + | ||
Unit commissioning |
Connect the unit to the customer-side connections (electricity, water, wastewater, gas), basic functions check, brief operating instructions. (excl.: unpacking, setup, controller instructions, programming, installation work) |
DL10-0100 | - | + | ||
Unit instructions |
Instruction regarding operating principle and basic functions of the unit, operation of the control electronics including programming |
DL10-0500 | - | + |
Designation |
CBS260-230V |
CBS260UL-120V |
---|---|---|
Option model | Standard | Standard |
Order number | 9040-0191 | 9040-0192 |
Data | ||
Serie | CB-S | CB-S |
Performance Data Temperature | ||
Recovery time after 30 seconds door open at 37 °C [min] | 8 | 8 |
Temperature fluctuation at 37 °C [± K] | 0.1 | 0.1 |
Temperature range +6 °C above ambient temperature to | 50 °C | 50 °C |
Temperature variation at 37 °C [± K] | 0.4 | 0.4 |
Performance Data Climate | ||
Humidity range [% RH] | 90…95 | 90…95 |
CO₂-Data | ||
CO₂ measurement | IR | IR |
CO₂ range [Vol.-% CO₂] | 0…20 | 0…20 |
CO₂ Recovery time after 30 seconds door open at 5 Vol.-% CO₂ [min] | 5 | 5 |
Electrical data | ||
Nominal power [kW] | 1.5 | 1.5 |
Phase (Nominal voltage) | 1~ | 1~ |
Power frequency [Hz] | 50/60 | 50/60 |
Rated Voltage [V] | 200…230 | 100…120 |
Unit fuse [A] | 10 | 16 |
Doors | ||
Inner doors | 1 | 1 |
Unit doors | 1 | 1 |
Housing dimensions not incl. fittings and connections | ||
Depth net [mm] | 785 | 785 |
Height net [mm] | 1020 | 1020 |
Width net [mm] | 740 | 740 |
Internal Dimensions | ||
Depth [mm] | 575 | 575 |
Height [mm] | 750 | 750 |
Width [mm] | 620 | 620 |
Measures | ||
Interior volume [L] | 267 | 267 |
Load per rack [kg] | 10 | 10 |
Net weight of the unit (empty) [kg] | 122 | 122 |
Permitted load [kg] | 40 | 40 |
Wall clearance back [mm] | 100 | 100 |
Wall clearance sidewise [mm] | 50 | 50 |
Environment-specific data | ||
Energy consumption at 37 °C [Wh/h] | 55 | 55 |
Sound-pressure level [dB(A)] | 41 | 41 |
Fixtures | ||
Number of shelves (std./max.) | 2/8 | 2/8 |
Performance Data Temperature | ||
Recovery time after 30 seconds door open at 37 °C [min] | 8 | 8 |
Temperature fluctuation at 37 °C [± K] | 0.1 | 0.1 |
Temperature range +6 °C above ambient temperature to | 50 °C | 50 °C |
Temperature variation at 37 °C [± K] | 0.4 | 0.4 |
Performance Data Climate | ||
Humidity range [% RH] | 90…95 | 90…95 |
CO₂-Data | ||
CO₂ measurement | IR | IR |
CO₂ range [Vol.-% CO₂] | 0…20 | 0…20 |
CO₂ Recovery time after 30 seconds door open at 5 Vol.-% CO₂ [min] | 5 | 5 |
Electrical data | ||
Nominal power [kW] | 1.5 | 1.5 |
Phase (Nominal voltage) | 1~ | 1~ |
Power frequency [Hz] | 50/60 | 50/60 |
Rated Voltage [V] | 200…230 | 100…120 |
Unit fuse [A] | 10 | 16 |
Doors | ||
Inner doors | 1 | 1 |
Unit doors | 1 | 1 |
Housing dimensions not incl. fittings and connections | ||
Depth net [in] | 30.93 | 30.93 |
Height net [in] | 40.2 | 40.2 |
Width net [in] | 29.16 | 29.16 |
Internal Dimensions | ||
Depth [in] | 22.65 | 22.65 |
Height [in] | 29.55 | 29.55 |
Width [in] | 24.43 | 24.43 |
Measures | ||
Interior volume [cu.ft.] | 9.4 | 9.4 |
Load per rack [lbs] | 22 | 22 |
Net weight of the unit (empty) [lbs] | 269 | 269 |
Permitted load [lbs] | 88 | 88 |
Wall clearance back [in] | 3.94 | 3.94 |
Wall clearance sidewise [in] | 1.97 | 1.97 |
Environment-specific data | ||
Energy consumption at 37 °C [Wh/h] | 55 | 55 |
Sound-pressure level [dB(A)] | 41 | 41 |
Fixtures | ||
Number of shelves (std./max.) | 2/8 | 2/8 |
Category | Title | File type / size | Download |
---|---|---|---|
Data Sheets |
CB-S 260 |
PDF (129.83 kB) | > |
Operating Manuals |
CB-S series |
PDF (6.08 MB) | > |
Technical Drawings |
Version CB-S260-120V 9040-0192 |
PDF (236.70 kB) | > |
Technical Drawings |
Version CB-S260-230V 9040-0191 |
PDF (241.80 kB) | > |
Case Studies |
CO₂ incubator (CB series) - Stem cell research into healing musculoskeletal disorders University of Rochester School of Medicine and Dentistry |
PDF (224.21 kB) | > |
White paper |
"Good laboratory practice" What is behind all this? |
PDF (246.32 kB) | > |
White paper |
Good Laboratory Practice Your checklist for GLP-compliant research and development |
PDF (808.38 kB) | > |
White paper |
Cell cultivation: for and against particular technical solutions in CO₂ incubators The parameters to consider |
PDF (184.17 kB) | > |
White paper |
Cell cultivation without contamination Hot air sterilization and other means of contamination control in CO₂ incubators |
PDF (250.25 kB) | > |
White paper |
Validation and Qualification In the regulated environment |
PDF (392.80 kB) | > |
Options & Accessories |
Stacking options for BINDER CO₂ incubators C | CB series |
PDF (161.65 kB) | > |
Brochures |
CO₂ incubators CB-S | CB series |
PDF (1.07 MB) | > |
Brochures |
BINDER Service 100 % performance and availability |
PDF (330.01 kB) | > |
Brochures |
BINDER INDIVIDUAL Series production devices for special requirements |
PDF (712.27 kB) | > |
Buyer´s Guide |
CO₂ incubators 6 things to consider when buying CO₂ incubators |
PDF (425.46 kB) | > |