Important characteristics
Details of the model
Select version
RRP* [?] | Merken | |
---|---|---|
Model MKT 240 | ||
|
- | + |
|
- | + |
Technical data
The PDF data sheet contains technical data, options & accessories as well as services.
Downloads
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
Rated voltage | Option model | Version | Art. No. | RRP* [?] | Selection | Bookmark |
---|---|---|---|---|---|---|
Model MKT 240 | ||||||
400 V 3~ 50 Hz | ||||||
Standard |
MKT240-400V | 9020-0386 | - | + | ||
480 V 3~ 60 Hz | ||||||
with voltage and frequency converter |
MKT240-480V-C | 9020-0364 | - | + |
Designation | Description | Art. No. | RRP* [?] | Bookmark | ||
---|---|---|---|---|---|---|
Access port | ||||||
notch-type access port in door, 100 x 35 mm |
8012-1855 | - | + | |||
Access port with silicone plug | ||||||
right |
8012-1321 | - | + | |||
left |
8012-1324 | - | + | |||
right |
8012-1327 | - | + | |||
left |
8012-1330 | - | + | |||
right |
8012-1333 | - | + | |||
left |
8012-1336 | - | + | |||
right |
8012-1350 | - | + | |||
left |
8012-1353 | - | + | |||
top |
8012-1532 | - | + | |||
top |
8012-1535 | - | + | |||
top |
8012-1538 | - | + | |||
right |
8012-1541 | - | + | |||
left |
8012-1544 | - | + | |||
Analog output 4-20 mA | ||||||
for temperature values (output not adjustable) |
8012-1785 | - | + | |||
Calibration certificate, expanded | ||||||
for temperature; for extending the measurement in center of chamber to include another test temperature |
8012-1125 | - | + | |||
Calibration certificate, temperature | ||||||
for temperature, measurement in center of chamber at specified temperature |
8012-1144 | - | + | |||
temperature measurement incl. certificate, 15- 18 measuring points at specified temperature |
8012-1582 | - | + | |||
temperature measurement incl. certificate and 27 measuring points at specified temperature |
8012-1603 | - | + | |||
temperature measurement incl. certificate, 9 measuring points at specified temperature |
8012-1561 | - | + | |||
Data Logger Kit | ||||||
T 220: For continuous temperature logging from -90 °C to 220 °C. The kit includes 1 data logger, Pt 100 sensor with 2 m extension cable and 1 magnetic fixture for mounting to the BINDER unit |
8012-0715 | - | + | |||
Door lock | ||||||
lockable door handle |
8012-1784 | - | + | |||
Dry-air purge | ||||||
uncontrolled, incl. connection; for preventing condensation |
8012-1867 | - | + | |||
Dry-air purge, connection | ||||||
for the connection to an existing pressurized air network |
8012-1788 | - | + | |||
Interface converter | ||||||
RS 422 cable set and RS 422 / Ethernet interface converter for connection to 10-way plug distributor or for connection to a unit |
8012-0380 | - | + | |||
RS 422 cable set and RS 422 / Ethernet interface converter for connection to 10-way plug distributor or for connection to a unit |
8012-0405 | - | + | |||
RS 422 cable set and RS 232 / RS 422 interface converter for connection to 10-way plug distributor or for connection to a unit |
8012-0556 | - | + | |||
RS 422 cable set and RS 232 / RS 422 interface converter for connection to 10-way plug distributor or for connection to a unit |
8012-0557 | - | + | |||
Interface converter, USB / RS422 | ||||||
RS 422 cable set and RS 422 / USB interface converter for connection to 10-way plug distributor or for connection to a unit (USB-powered converter) |
8012-0665 | - | + | |||
pH-neutral detergent | ||||||
concentrated, for gentle remove of residual contaminants; 1 kg |
1002-0016 | - | + | |||
Pt 100 temperature sensor | ||||||
additional flexible Pt 100, interior, for displaying the temperature on the unit display |
8012-1790 | - | + | |||
Rack | ||||||
stainless steel |
6004-0097 | - | + | |||
Rack accessories | ||||||
fasteners (1 set of 4) for additional security of racks |
8012-0620 | - | + | |||
Rack, reinforced | ||||||
stainless steel, with fasteners (1 set of 4) |
8012-0605 | - | + | |||
RS 422 interface | ||||||
modular plug distributor for 10 RS 422 interfaces |
8012-0295 | - | + | |||
RS 422 interface, cable (15 m) | ||||||
RS 422 connection cable (15 m) between plug distributor and RS 422 interface |
5023-0036 | - | + | |||
RS 422 interface, cable (50 m) | ||||||
RS 422 extension cable (50 m) between interface converter and unit or RS 232 / RS 422 plug distributor |
5023-0117 | - | + | |||
RS 485 / RS 422 interface converter | ||||||
RS 422 cable set and RS 485 / RS 422 interface converter for connection to 10-way plug distributor |
8012-0599 | - | + | |||
RS 422 cable set and RS 485 / RS 422 interface converter for connection to 10-way plug distributor |
8012-0589 | - | + | |||
RS 485 interface, 2-wire | ||||||
Additional serial interface can be used parallel to Ethernet, for Multi Management Software APT-COM™ |
8012-1770 | - | + | |||
Shelf, perforated | ||||||
|
8009-0447 | - | + | |||
Temperature safety device class 2 | ||||||
with visual alarm (DIN 12880) |
8012-1794 | - | + |
Designation | Description | Art. No. | RRP* [?] | Bookmark | ||
---|---|---|---|---|---|---|
Calibration temperature incl. certificate |
including certificate, one measuring point in center of chamber at specified temperature |
DL30-0101 | - | + | ||
Execution of IQ/OQ |
in accordance with qualification folder |
DL41-0200 | - | + | ||
Execution of IQ/OQ/PQ |
in accordance with customer's requirement, price: on request |
DL44-0500 | - | + | ||
Extension of the warranty from 2 to 3 years |
beginning with the date of delivery, wearing parts are not included |
DL01-2041 | - | + | ||
Extension of the warranty from 2 to 5 years |
beginning with the date of delivery, wearing parts are not included |
DL01-2042 | - | + | ||
Installation |
and set up of unit at operating location, connect to existing connections |
DL10-0300 | - | + | ||
Instruction |
unit function instructions for operation and programming of the controller |
DL10-0700 | - | + | ||
Preventive maintenance |
Executive of equipment inspection according to maintenance plan |
DL20-0500 | - | + | ||
Qualification folder IQ/OQ |
supporting documents for validation performed by customer, consisting of: IQ/OQ checklists, unit schematics, QM certificate in accordance with ISO 9001 |
8012-0864 | - | + | ||
Qualification folder IQ/OQ/PQ |
supporting documents for validation performed by customer, in accordance with customer's requirement, extension of Qualification folder IQ/OQ by chapter PQ |
8012-0952 | - | + | ||
Temperature measurement 18 measuring points |
including certificate, 18 measuring points at specified temperature |
DL30-0118 | - | + | ||
Temperature measurement 27 measuring points |
including certificate, 27 measuring points at specified temperature |
DL30-0127 | - | + | ||
Temperature measurement 9 measuring points |
including certificate, 9 measuring points at specified temperature |
DL30-0109 | - | + |
Designation |
MKT240-400V¹ |
MKT240-480V-C¹ |
---|---|---|
Option model | Standard | with voltage and frequency converter |
Order number | 9020-0386 | 9020-0364 |
Performance Data Temperature | ||
Average cooling down time according to IEC 60068-3-5 [K/min] | 4.2 | 4.2 |
Average heating-up rate according to IEC 60068-3-5 [K/min] | 5 | 5 |
Cooling down time from 180 °C to -70 °C [min] | 95 | 95 |
Max. heat compensation at 25 °C [W] | 3200 | 3200 |
Temperature fluctuation depending on setpoint [± K] | 0.1…0.4 | 0.1…0.4 |
Temperature range [°C] | -70…180 | -70…180 |
Temperature variation depending on setpoint [± K] | 0.1…1.0 | 0.1…1.0 |
Electrical data | ||
Nominal power [kW] | 6.5 | 6.5 |
Phase (Nominal voltage) | 3~ | 3~ |
Power frequency [Hz] | 50 | 60 |
Rated Voltage [V] | 400 | 480 |
Unit fuse [A] | 16 | 16 |
Doors | ||
Unit doors | 1 | 1 |
Internal Dimensions | ||
Depth [mm] | 443 | 443 |
Height [mm] | 700 | 700 |
Width [mm] | 735 | 735 |
Measures | ||
Interior volume [L] | 228 | 228 |
Load per rack [kg] | 30 | 30 |
Net weight of the unit (empty) [kg] | 380 | 380 |
permitted load [kg] | 70 | 70 |
Outer dimensions | ||
Depth net [mm] | 925 | 925 |
Height net [mm] | 1935 | 1935 |
Viewing window height [mm] | 300 | 300 |
Viewing window width [mm] | 508 | 508 |
Wall clearance back [mm] | 300 | 300 |
Wall clearance sidewise [mm] | 200 | 200 |
Width net [mm] | 1115 | 1115 |
Environment-specific data | ||
Sound-pressure level [dB(A)] | 64 | 67 |
Fixtures | ||
Number of shelves (std./max.) | 1/6 | 1/6 |
Performance Data Temperature | ||
Average cooling down time according to IEC 60068-3-5 [K/min] | 4.2 | 4.2 |
Average heating-up rate according to IEC 60068-3-5 [K/min] | 5 | 5 |
Cooling down time from 180 °C to -70 °C [min] | 95 | 95 |
Max. heat compensation at 25 °C [W] | 3200 | 3200 |
Temperature fluctuation depending on setpoint [± K] | 0.1…0.4 | 0.1…0.4 |
Temperature range [°C] | -70…180 | -70…180 |
Temperature variation depending on setpoint [± K] | 0.1…1 | 0.1…1 |
Electrical data | ||
Nominal power [kW] | 6.5 | 6.5 |
Phase (Nominal voltage) | 3~ | 3~ |
Power frequency [Hz] | 50 | 60 |
Rated Voltage [V] | 400 | 480 |
Unit fuse [A] | 16 | 16 |
Doors | ||
Unit doors | 1 | 1 |
Internal Dimensions | ||
Depth [in] | 17.45 | 17.45 |
Height [in] | 27.58 | 27.58 |
Width [in] | 28.96 | 28.96 |
Measures | ||
Interior volume [cu.ft.] | 8 | 8 |
Load per rack [lbs] | 66 | 66 |
Net weight of the unit (empty) [lbs] | 838 | 838 |
permitted load [lbs] | 154 | 154 |
Outer dimensions | ||
Depth net [in] | 36.45 | 36.45 |
Height net [in] | 76.2 | 76.2 |
Viewing window height [in] | 11.82 | 11.82 |
Viewing window width [in] | 20.02 | 20.02 |
Wall clearance back [in] | 11.82 | 11.82 |
Wall clearance sidewise [in] | 7.88 | 7.88 |
Width net [in] | 43.9 | 43.9 |
Environment-specific data | ||
Sound-pressure level [dB(A)] | 64 | 67 |
Fixtures | ||
Number of shelves (std./max.) | 1/6 | 1/6 |
Category | Title | File type / size | Download |
---|---|---|---|
Data Sheets |
MKT 240 |
PDF (225.29 kB) | > |
Operating Manuals |
MK | MKT series E5 Model 56 | 115 | 240 | 720 |
PDF (10.48 MB) | > |
Technical Drawings |
Version MKT240-400V-C 9020-0364 |
PDF (344.32 kB) | > |
Technical Drawings |
Version MKT240-400V 9020-0386 |
PDF (361.96 kB) | > |
Case Studies |
Dynamic climate chambers (Series MKT) - Test systems for building materials infra Test Prueftechnik GmbH |
PDF (941.80 kB) | > |
Brochures |
Dynamic climate chambers MK | MKF | MKT | MKFT series |
PDF (2.05 MB) | > |
White paper |
Trends in consumer behavior How has the food industry changed in industrialized countries? |
PDF (157.03 kB) | > |
White paper |
Artificial aging Predicting material behavior |
PDF (435.64 kB) | > |
Options & Accessories |
Dynamic climate chambers with dry-air purge MK | MKF | MKT | MKFT series |
PDF (614.49 kB) | > |
Options & Accessories |
Cell and module test chamber for lithium-ion energy storage devices Additional safety measures on the MK 240 dynamic climate chamber |
PDF (330.35 kB) | > |
Options & Accessories |
Data Logger Kits – temperature and humidity Data Logger Kit NET 100 | Data Logger Kit NET 100/60 |
PDF (256.74 kB) | > |
Buyer´s Guide |
Dynamic climate chamber 5 key factors to consider when buying dynamic climate chambers |
PDF (3.59 MB) | > |