Important characteristics
Details of the model
Select version
RRP* [?] | Merken | |
---|---|---|
Model KBF 115 | ||
|
- | + |
|
- | + |
Technical data
The PDF data sheet contains technical data, options & accessories as well as services.
Downloads
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
Rated voltage | Option model | Version | Art. No. | RRP* [?] | Selection | Bookmark |
---|---|---|---|---|---|---|
Model KBF 115 | ||||||
200…230 V 1~ 50/60 Hz | ||||||
Standard |
KBF115-230V | 9020-0320 | - | + | ||
200…240 V 1~ 50/60 Hz | ||||||
Standard |
KBF115UL-240V | 9020-0321 | - | + |
Designation | Description | Art. No. | RRP* [?] | Bookmark | ||
---|---|---|---|---|---|---|
Access port with silicone plug | ||||||
right |
8012-0514 | - | + | |||
left |
8012-0515 | - | + | |||
right |
8012-1436 | - | + | |||
left |
8012-1442 | - | + | |||
top |
8012-1448 | - | + | |||
top |
8012-1454 | - | + | |||
top |
8012-1460 | - | + | |||
right |
8012-1466 | - | + | |||
left |
8012-1472 | - | + | |||
Alarm output, zero-voltage | ||||||
for temperature (±2 °C) and humidity (±5 % RH), accessible via 6-pin DIN socket (max. 24 V - 2.5 A), with audible signal that can be switched off |
8012-1036 | - | + | |||
Analog output 4-20 mA | ||||||
for temperature and humidity values (output not adjustable) |
8012-1039 | - | + | |||
BINDER PURE AQUA SERVICE | ||||||
system for preparation or complete desalination of tap water, containing single-use cartridge, hoses and measuring device |
8012-0759 | - | + | |||
BINDER PURE AQUA SERVICE, accessories | ||||||
Single-use, replacement cartridge for BINDER PURE AQUA System |
6011-0165 | - | + | |||
Calibration certificate, expanded | ||||||
for temperature and humidity; for extending the measurement in center of chamber to include another test value |
8012-0155 | - | + | |||
Calibration certificate, temperature | ||||||
temperature measurement incl. certificate, 9 measuring points at specified temperature |
8012-0917 | - | + | |||
temperature measurement incl. certificate, 15- 18 measuring points at specified temperature |
8012-0920 | - | + | |||
temperature measurement incl. certificate and 27 measuring points at specified temperature |
8012-0923 | - | + | |||
Calibration certificate, temperature and humidity | ||||||
Measurement in center of chamber at 25 °C / 60% RH or at specified test values |
8012-0154 | - | + | |||
temperature (according to DIN12880) and humidity measurement incl. certificate, 27 temperature measuring points and 1 humidity measuring point, at 25 °C / 60 % RH or at specified values |
8012-0924 | - | + | |||
Class 3.3 independent temperature safety device | ||||||
with visual alarm (DIN 12880) |
8012-1032 | - | + | |||
Converter, voltage | ||||||
to operate the device at a nominal voltage of 120 V 1 ph 60 Hz |
8009-0821 | - | + | |||
Data Logger Kit | ||||||
TH 70/70: For continuous temperature and humidity logging from -40 °C to 70 °C / 0% to 100% RH and additional logging of ambient conditions. Kit includes 1 data logger, 2 attachable combined humidity/temperature sensors, 2 m extension cable and 1 fixture for mounting to the BINDER unit |
8012-0717 | - | + | |||
T 220: For continuous temperature logging from -90 °C to 220 °C. The kit includes 1 data logger, Pt 100 sensor with 2 m extension cable and 1 magnetic fixture for mounting to the BINDER unit |
8012-0715 | - | + | |||
TH 70: For continuous temperature and humidity logging from -40 °C to 70 °C; 0% to 100% RH. Kit includes 1 data logger, Pt 100 sensor with 2 m extension cable, and 1 magnetic fixture for mounting to the BINDER unit |
8012-0716 | - | + | |||
Data Logger Software | ||||||
LOG ANALYZE software kit, configuration and evaluation software for all BINDER Data Logger Kits (incl. USB data cable) |
8012-0821 | - | + | |||
Door lock | ||||||
lockable door handle |
8012-1023 | - | + | |||
Interface converter | ||||||
RS 422 cable set and RS 232 / RS 422 interface converter for connection to 10-way plug distributor or for connection to a unit |
8012-0556 | - | + | |||
RS 422 cable set and RS 232 / RS 422 interface converter for connection to 10-way plug distributor or for connection to a unit |
8012-0557 | - | + | |||
RS 422 cable set and RS 422 / Ethernet interface converter for connection to 10-way plug distributor or for connection to a unit |
8012-0380 | - | + | |||
RS 422 cable set and RS 422 / Ethernet interface converter for connection to 10-way plug distributor or for connection to a unit |
8012-0405 | - | + | |||
Interface converter, USB / RS422 | ||||||
RS 422 cable set and RS 422 / USB interface converter for connection to 10-way plug distributor or for connection to a unit (USB-powered converter) |
8012-0665 | - | + | |||
Interior socket | ||||||
Waterproof, switched flush-mounting box (CA3GD) for nominal voltage in unit interior, with cover and corresponding plug (nominal voltage; max. 500 W; max. 90 °C; protection class IP67) |
8012-1043 | - | + | |||
LED light bars | ||||||
Basic set consisting of 2 pieces, attachment material, control unit for max. 4 light strips, 100-240 V, 50/60 Hz |
8012-1107 | - | + | |||
Expansion set consisting of 2 pieces, attachment material: clips. For expanding the basic set of light bars |
8012-1716 | - | + | |||
Basic set consisting of 2 pieces, attachment material, control unit for max. 4 light strips, 100-240 V, 50/60 Hz |
8012-1108 | - | + | |||
Expansion set consisting of 2 pieces, attachment material: clips. For expanding the basic set of light bars |
8012-1717 | - | + | |||
pH-neutral detergent | ||||||
concentrated, for gentle remove of residual contaminants; 1 kg |
1002-0016 | - | + | |||
Pt 100 temperature sensor | ||||||
additional flexible Pt 100, interior, for displaying the temperature on the unit display |
8012-1042 | - | + | |||
Rack | ||||||
stainless steel |
6004-0112 | - | + | |||
Rack accessories | ||||||
fasteners (1 set of 4) for additional security of racks |
8012-0620 | - | + | |||
Rack, reinforced | ||||||
stainless steel, with fasteners (1 set of 4) |
8012-0700 | - | + | |||
RS 422 interface | ||||||
modular plug distributor for 10 RS 422 interfaces |
8012-0295 | - | + | |||
RS 422 interface, cable (15 m) | ||||||
RS 422 connection cable (15 m) between plug distributor and RS 422 interface |
5023-0036 | - | + | |||
RS 422 interface, cable (50 m) | ||||||
RS 422 extension cable (50 m) between interface converter and unit or RS 232 / RS 422 plug distributor |
5023-0117 | - | + | |||
RS 485 interface, 2-wire | ||||||
Additional serial interface can be used parallel to Ethernet, for Multi Management Software APT-COM™ |
8012-1066 | - | + | |||
Shelf, perforated | ||||||
|
6004-0115 | - | + | |||
Water supply set | ||||||
external, consisting of fresh- and waste-water containers (20 liters each), cabling and pump |
8012-0643 | - | + | |||
consisting of fresh- and waste-water containers (20 liters each), cabling and pump |
8012-1846 | - | + |
Designation | Description | Art. No. | RRP* [?] | Bookmark | ||
---|---|---|---|---|---|---|
Calibration temperature and humidity |
including certificate, one measuring point in center of chamber at 25 °C / 60 % RH or at specified values |
DL30-0301 | - | + | ||
Execution of IQ/OQ |
in accordance with qualification folder |
DL42-0300 | - | + | ||
Execution of IQ/OQ/PQ |
in accordance with customer's requirement, price: on request |
DL44-0500 | - | + | ||
Extension of the warranty from 2 to 3 years |
beginning with the date of delivery, wearing parts are not included |
DL01-4041 | - | + | ||
Extension of the warranty from 2 to 5 years |
beginning with the date of delivery, wearing parts are not included |
DL01-4042 | - | + | ||
Installation |
and set up of unit at operating location, connect to existing connections |
DL10-0300 | - | + | ||
Instruction |
unit function instructions for operation and programming of the controller |
DL10-0700 | - | + | ||
Preventive maintenance |
Executive of equipment inspection according to maintenance plan |
DL20-0400 | - | + | ||
Qualification folder IQ/OQ |
supporting documents for validation performed by customer, consisting of: IQ/OQ checklists, unit schematics, QM certificate in accordance with ISO 9001 |
8012-0867 | - | + | ||
Qualification folder IQ/OQ/PQ |
supporting documents for validation performed by customer, in accordance with customer's requirement, extension of Qualification folder IQ/OQ by chapter PQ |
8012-0955 | - | + | ||
Temperature and humidity measurement according to DIN12880 |
including certificate (27 temperature measuring points and one humidity measuring point, at 25 °C / 60 % RH or at specified values) |
DL30-0427 | - | + | ||
Temperature measurement 18 temperature measuring points and 1 humidity measuring point |
including certificate, 18 temperature measuring points and 1 humidity measuring point in center of chamber, at 25 °C / 60 % RH or at specified values |
DL30-0318 | - | + | ||
Temperature measurement 27 temperature measuring points and 1 humidity measuring point |
including certificate, 27 temperature measuring points and 1 humidity measuring point in center of chamber, at 25 °C / 60 % RH or at specified values |
DL30-0327 | - | + | ||
Temperature measurement 9 temperature measuring points and 1 humidity measuring point |
including certificate, 9 temperature measuring points and 1 humidity measuring point in center of chamber, at 25 °C / 60 % RH or at specified values |
DL30-0309 | - | + |
Designation |
KBF115-230V¹ |
KBF115UL-240V¹ |
---|---|---|
Option model | Standard | Standard |
Order number | 9020-0320 | 9020-0321 |
Performance Data Temperature | ||
Max. heat compensation at 40 °C [W] | 200 | 200 |
Temperature fluctuation [± K] | 0.1 | 0.1 |
Temperature range [°C] | 0…70 | 0…70 |
Temperature variation at 40 °C [± K] | 0.2 | 0.2 |
Performance Data Climate | ||
Humidity fluctuation at 25 °C and 60 % RH | ≤2 ± % RH | ≤2 ± % RH |
Humidity fluctuation at 40 °C and 75 % RH | ≤2 ± % RH | ≤2 ± % RH |
Humidity range [% RH] | 10…80 | 10…80 |
Humidty recovery time after 30 s door open at 25 °C and 60 % RH [min] | 6 | 6 |
Humidty recovery time after 30 s door open at 40 °C and 75 % RH [min] | 7 | 7 |
Temperature fluctuation at 25 °C and 60 % RH [± K] | 0.1 | 0.1 |
Temperature fluctuation at 40 °C and 75 % RH [± K] | 0.1 | 0.1 |
Temperature range [°C] | 10…70 | 10…70 |
Temperature variation at 25 °C and 60 % RH [± K] | 0.2 | 0.2 |
Temperature variation at 40 °C and 75 % RH [± K] | 0.2 | 0.2 |
Electrical data | ||
Nominal power [kW] | 2 | 2 |
Phase (Nominal voltage) | 1~ | 1~ |
Power frequency [Hz] | 50/60 | 50/60 |
Rated Voltage [V] | 200…230 | 200…240 |
Unit fuse [A] | 16 | 16 |
Doors | ||
Inner doors | 1 | 1 |
Unit doors | 1 | 1 |
Internal Dimensions | ||
Depth [mm] | 351 | 351 |
Height [mm] | 483 | 483 |
Width [mm] | 600 | 600 |
Measures | ||
Interior volume [L] | 102 | 102 |
Load per rack [kg] | 30 | 30 |
Net weight of the unit (empty) [kg] | 129 | 129 |
permitted load [kg] | 100 | 100 |
Outer dimensions | ||
Depth net [mm] | 650 | 650 |
Height net [mm] | 1050 | 1050 |
Wall clearance back [mm] | 100 | 100 |
Wall clearance sidewise [mm] | 100 | 100 |
Width net [mm] | 880 | 880 |
Environment-specific data | ||
Energy consumption at 40 °C and 75 % RH [Wh/h] | 470 | 470 |
Sound-pressure level [dB(A)] | 52 | 52 |
Fixtures | ||
Number of shelves (std./max.) | 2/5 | 2/5 |
Performance Data Temperature | ||
Max. heat compensation at 40 °C [W] | 200 | 200 |
Temperature fluctuation [± K] | 0.1 | 0.1 |
Temperature range [°C] | 0…70 | 0…70 |
Temperature variation at 40 °C [± K] | 0.2 | 0.2 |
Performance Data Climate | ||
Humidity fluctuation at 25 °C and 60 % RH | ≤2 ± % RH | ≤2 ± % RH |
Humidity fluctuation at 40 °C and 75 % RH | ≤2 ± % RH | ≤2 ± % RH |
Humidity range [% RH] | 10…80 | 10…80 |
Humidty recovery time after 30 s door open at 25 °C and 60 % RH [min] | 6 | 6 |
Humidty recovery time after 30 s door open at 40 °C and 75 % RH [min] | 7 | 7 |
Temperature fluctuation at 25 °C and 60 % RH [± K] | 0.1 | 0.1 |
Temperature fluctuation at 40 °C and 75 % RH [± K] | 0.1 | 0.1 |
Temperature range [°C] | 10…70 | 10…70 |
Temperature variation at 25 °C and 60 % RH [± K] | 0.2 | 0.2 |
Temperature variation at 40 °C and 75 % RH [± K] | 0.2 | 0.2 |
Electrical data | ||
Nominal power [kW] | 2 | 2 |
Phase (Nominal voltage) | 1~ | 1~ |
Power frequency [Hz] | 50/60 | 50/60 |
Rated Voltage [V] | 200…230 | 200…240 |
Unit fuse [A] | 16 | 16 |
Doors | ||
Inner doors | 1 | 1 |
Unit doors | 1 | 1 |
Internal Dimensions | ||
Depth [in] | 13.83 | 13.83 |
Height [in] | 19.03 | 19.03 |
Width [in] | 23.64 | 23.64 |
Measures | ||
Interior volume [cu.ft.] | 3.6 | 3.6 |
Load per rack [lbs] | 66 | 66 |
Net weight of the unit (empty) [lbs] | 284 | 284 |
permitted load [lbs] | 220 | 220 |
Outer dimensions | ||
Depth net [in] | 25.61 | 25.61 |
Height net [in] | 41.4 | 41.4 |
Wall clearance back [in] | 3.94 | 3.94 |
Wall clearance sidewise [in] | 3.94 | 3.94 |
Width net [in] | 34.67 | 34.67 |
Environment-specific data | ||
Energy consumption at 40 °C and 75 % RH [Wh/h] | 470 | 470 |
Sound-pressure level [dB(A)] | 52 | 52 |
Fixtures | ||
Number of shelves (std./max.) | 2/5 | 2/5 |
Category | Title | File type / size | Download |
---|---|---|---|
Data Sheets |
KBF 115 |
PDF (164.98 kB) | > |
Operating Manuals |
KBF | KMF series |
PDF (11.49 MB) | > |
Operating Manuals |
PURE AQUA SERVICE (E3) Water treatment system Mounting Instructions |
PDF (4.30 MB) | > |
Technical Drawings |
Model KBF 115 External dimensions |
PDF (113.93 kB) | > |
Technical Drawings |
Model KBF 115 Access ports |
PDF (127.66 kB) | > |
Case Studies |
Constant climate chambers (Series KBF) - Putting labels through their paces in BINDER chambers Schreiner Group GmbH & Co. KG |
PDF (256.05 kB) | > |
Case Studies |
Constant climate chambers (Series KBF) - Material testing Aspect Quality GmbH |
PDF (1.33 MB) | > |
Case Studies |
Constant climate chambers (Series KBF) - Drug safety Diapharm GmbH & Co. KG |
PDF (365.89 kB) | > |
Case Studies |
Constant climate chambers (KBF series) - Desiccants – the all-round talent against corrosion damage TROPACK Packmittel GmbH |
PDF (1.64 MB) | > |
Brochures |
Constant climate chambers KBF | KBF-S | KBF P | KBF LQC | KMF series |
PDF (2.00 MB) | > |
White paper |
Trends in consumer behavior How has the food industry changed in industrialized countries? |
PDF (157.03 kB) | > |
White paper |
Accelerated Shelf-life Testing Of Natural Colours in Model Food Systems |
PDF (765.50 kB) | > |
Options & Accessories |
PURE AQUA SERVICE Serie KBF| KBF P | KBF LQC | KMF | KBWF | MKF | MKFT |
PDF (335.95 kB) | > |
Buyer´s Guide |
Constant climate chambers KBF 6 points to consider when purchasing a constant climate chamber in the pharmaceutical industry |