Series CB | CO₂ incubators with hot air sterilization and heat sterilizable CO₂ sensor

Important characteristics

  • Temperature range: room temperature plus 7 °C to 60 °C
  • Humidity range: up to 95% RH
  • Alternative O₂ control ranges: 0.2-20 vol. % O₂ or 10-95 vol. % O₂ (O, GO versions)
  • Auto-sterilization with hot air at 180 °C
  • Double-pan humidification system with condensation protection
  • CO₂ gas-mixing jet with Venturi effect
  • Hot-air sterilizable CO₂ sensor with infrared technology
  • Display via color LCD monitor
  • Lockable door handle
  • Tightly-sealed inner door made of tempered safety glass
  • Seamless, deep-drawn inner stainless steel chamber
  • 2/3 perforated stainless steel shelves
  • Units are stackable with stacking adapter
  • Troubleshooting system with visual and audible alarms
  • Computer interface: Ethernet
  • Internal data recording and USB interface
  • Zero-voltage alarm contact
Models
  • Model CB 60
  • Housing dimensions not incl. fittings and connections - W x H x D [mm]: 580 x 720 x 545
  • Internal dimension W x H x D [mm]: 400 x 400 x 330
  • Net weight [kg]: 68
  • Interior volume [L]: 53
  • Bookmark +
  • Model CB 160
  • Housing dimensions not incl. fittings and connections - W x H x D [mm]: 680 x 920 x 715
  • Internal dimension W x H x D [mm]: 500 x 600 x 500
  • Net weight [kg]: 110
  • Interior volume [L]: 150
  • Bookmark +
  • Model CB 220
  • Housing dimensions not incl. fittings and connections - W x H x D [mm]: 740 x 1070 x 715
  • Internal dimension W x H x D [mm]: 560 x 750 x 500
  • Net weight [kg]: 132
  • Interior volume [L]: 210
  • Bookmark +
Technical data

Please select a model to view technical data:

Services
RRP* [?] Merken
  • Designation:

    Calibration CO₂

  • Description:

    including certificate, CO₂ measurement with analyzed test gas at 5 % or at specified value

  • Art. No.: DL30-0401
- +
  • Designation:

    Calibration O₂

  • Description:

    calibration of O₂, including certificate (one measuring point in center of chamber at specified O₂ percentage)

  • Art. No.: DL30-0402
- +
  • Designation:

    Calibration temperature incl. certificate

  • Description:

    including certificate, one measuring point in center of chamber at specified temperature

  • Art. No.: DL30-0101
- +
  • Designation:

    Data Logger Kit installation service

  • Description:

    unit function instructions for operation and programming of the controller

  • Art. No.: DL10-0500
- +
  • Designation:

    Execution of IQ/OQ

  • Description:

    in accordance with qualification folder

  • Art. No.: DL41-0200
- +
  • Designation:

    Execution of IQ/OQ/PQ

  • Description:

    in accordance with customer's requirement, price: on request

  • Art. No.: DL44-0500
- +
  • Designation:

    Extension of the warranty from 2 to 3 years

  • Description:

    beginning with the date of delivery, wearing parts are not included

  • Art. No.: DL02-1041
- +
  • Designation:

    Extension of the warranty from 2 to 5 years

  • Description:

    beginning with the date of delivery, wearing parts are not included

  • Art. No.: DL02-1042
- +
  • Designation:

    Installation

  • Description:

    and set up of unit at operating location, connect to existing connections

  • Art. No.: DL10-0200
- +
  • Designation:

    Preventive maintenance

  • Description:

    Executive of equipment inspection according to maintenance plan

  • Art. No.: DL20-0400
- +
  • Designation:

    Qualification folder IQ/OQ

  • Description:

    supporting documents for validation performed by customer, consisting of: IQ/OQ checklists, unit schematics, QM certificate in accordance with ISO 9001

  • Art. No.: 8012-0876
- +
  • Designation:

    Qualification folder IQ/OQ/PQ

  • Description:

    supporting documents for validation performed by customer, in accordance with customer's requirement, extension of Qualification folder IQ/OQ by chapter PQ

  • Art. No.: 8012-0963
- +
  • Designation:

    Temperature measurement 18 measuring points

  • Description:

    including certificate, 18 measuring points at specified temperature

  • Art. No.: DL30-0118
- +
  • Designation:

    Temperature measurement 27 measuring points

  • Description:

    including certificate, 27 measuring points at specified temperature

  • Art. No.: DL30-0127
- +
  • Designation:

    Temperature measurement 9 measuring points

  • Description:

    including certificate, 9 measuring points at specified temperature

  • Art. No.: DL30-0109
- +
Options and Accessories

Complementary to our products we offer a broad range of options and accessories - from access ports and to racks to documentation and software.

Please select a model to get an overview of all available options and accessories for this product:

Downloads

CB series

  • Category: Operating Manuals
  • File type / size PDF (5.58 MB)

CO₂ incubator (Series CB) - Herd breeding BETAGRAN Lipetsk LLC, Lipetsk

  • Category: Case Studies
  • File type / size PDF (306.70 kB)

CO₂ incubator (Series CB) - Stem cell research into healing musculoskeletal disorders University of Rochester School of Medicine and Dentistry

  • Category: Case Studies
  • File type / size PDF (224.21 kB)

CO₂ incubators (Series CB) - Skin transplants German Institute for Cell and Tissue Replacement (DIZG)

  • Category: Case Studies
  • File type / size PDF (615.04 kB)

CO₂ incubators (Series CB) | Ultralow temperature freezers (Series UF V) | Incubators (Series BD) - Regenerative medicine Bioscience Clinic - Middle East FZ-LLC

  • Category: Case Studies
  • File type / size PDF (713.24 kB)

CO₂ incubators (Series CB) - Regenerative medicine Swiss Center for Regenerative Medicine (SCRM)

  • Category: Case Studies
  • File type / size PDF (1.07 MB)

CO₂ incubators (Series CB ) - Stem cell research The Huck Institutes of the Life Sciences Pennsylvania State University

  • Category: Case Studies
  • File type / size PDF (1.23 MB)

CO₂ incubators (CB series) – Successful reproduction of human skin cells Sysmex Suisse AG

  • Category: Case Studies
  • File type / size PDF (200.14 kB)

CO₂ incubators C | CB series

  • Category: Brochures
  • File type / size PDF (1.46 MB)

Cell cultivation without contamination Hot air sterilization and other means of contamination control in CO₂ incubators

  • Category: White paper
  • File type / size PDF (299.90 kB)

Validation and Qualification In the regulated environment

  • Category: White paper
  • File type / size PDF (498.89 kB)

Stacking options for BINDER CO₂ incubators C | CB series

  • Category: Options & Accessories
  • File type / size PDF (567.67 kB)

CO₂ incubators 6 things to consider when buying CO₂ incubators

  • Category: Buyer´s Guide
  • File type / size PDF (425.46 kB)

CO₂ incubators with hot air sterilization and heat sterilizable CO₂ sensor

The Binder CB series is a world first! Fitted with a sterilizable CO₂ sensor, the incubator meets the highest of standards when it comes to sample safety and cell growth. While C series CO₂ incubators have been designed with standard laboratory applications in mind, the BINDER CB comes highly recommended for the incubation of delicate cells, providing optimum growth conditions for cell cultures.

Just like the C series units, the CO₂ incubators in the CB series have the option of automatic sterilization with hot air at 180 °C. Plus, they have a heat sterilizable CO₂ sensor with infrared technology and come with a double-pan humidification system with condensation protection. The units feature tightly sealed inner doors made of tempered safety glass and a lockable door handle, guaranteeing maximum safety conditions for work in the laboratory.

CO₂ incubators with a patented humidity management system

CB series CO₂ incubators have a patented humidity management system. The Permadry double-pan humidity system provides active humidity limitation that keeps even the interior walls dry. What's more, evaporation is kept to a minimum thanks to the high humidity.

These CO₂ incubators are incredibly user-friendly, with the option to control all of the key parameters at once using the operating panel. Measured values are recorded continually and can be exported as data sets with ease via USB. Navigation is straightforward and intuitive.

The CO₂ incubators with hot air sterilization and heat sterilizable CO₂ sensor are ideal for the incubation of delicate cells, guaranteeing optimum conditions for cell cultures along with high levels of safety and usability.