Series FDL | Safety drying chambers for limited quantities of solvent

The BINDER FDL 115 with silicone and dust-free inner chamber, as well as symmetric airflow dries specimens containing solvents and thus this safety drying oven meets all EN 1539 requirements.

Benefits

  • Safety concept meets the DIN EN 1539-2010-08 standard
  • Short drying time with high temperature accuracy and defined ventilation
  • Silicone free and dust-free inner chamber
  • Replaceable fresh air cartridges are easy to change and ensure constant fresh air quality

Important characteristics

  • Temperature range: +10 °C above ambient temperature to +300 °C
  • APT.line™ preheating chamber technology
  • Controller with time-segment and real-time programming
  • 2 chrome-plated racks
  • Fresh-air monitoring with audible and visual alarm and automatic deactivation of heating
  • Replaceable filter cartridge, Class M6
  • Class 2 independent adjustable temperature safety device (DIN 12880) with visual alarm
  • Computer interface: RS 422
  • Standard door gasket made from solvent-resistant FKM for use at up to 200 °C
  • Optional door gasket made from silicone with limited solvent resistance for use at up to 300 °C
Models
  • Model FDL 115
  • Housing dimensions not incl. fittings and connections - W x H x D [mm]: 830 x 805 x 685
  • Internal dimension W x H x D [mm]: 600 x 435 x 435
  • Net weight [kg]: 90
  • Interior volume [L]: 115
  • Bookmark +
Technical data

Please select a model to view technical data:

Services
RRP* [?] Merken
  • Designation:

    Calibration certificate, temperature

  • Description:

    Extension of calibration of one (1) additional test temperature specified by the user in the center of the usable space, including certificate

  • Art. No.: DL30-0102
- +
  • Designation:

    Calibration certificate, temperature

  • Description:

    Calibration of one (1) test temperature specified by the user in center of chamber including certificate

  • Art. No.: DL30-0101
- +
  • Designation:

    Execution of IQ/OQ

  • Description:

    Execution of IQ/OQ in accordance with qualification folder

  • Art. No.: DL40-0100
- +
  • Designation:

    Execution of IQ/OQ/PQ

  • Description:

    Execution of IQ/OQ/PQ in accordance with qualification folder

  • Art. No.: DL44-0500
- +
  • Designation:

    Maintenance

  • Description:

    Maintenance service in accordance with maintenance schedule. Visual inspection of mechanical and electrical components, testing of all key functions. Calibration of a test temperature specified by the user in center of chamber without certificate

  • Art. No.: DL20-0200
- +
  • Designation:

    Measurement of air exchange rate

  • Description:

    including certificate (in accordance with ASTM D5374)

  • Art. No.: DL33-0000
- +
  • Designation:

    Temperature measurement, 18 measuring points

  • Description:

    Temperature measurement with 18 measuring points with a set value specified by the user, including certificate

  • Art. No.: DL30-0118
- +
  • Designation:

    Temperature measurement, 27 measuring points

  • Description:

    Temperature measurement with 27 measuring points with a set value specified by the user, including certificate

  • Art. No.: DL30-0127
- +
  • Designation:

    Temperature measurement, 9 measuring points

  • Description:

    Temperature measurement with 9 measuring points with a set value specified by the user, including certificate

  • Art. No.: DL30-0109
- +
  • Designation:

    Unit commissioning

  • Description:

    Connect the unit to the customer-side connections (electricity, water, wastewater, gas), basic functions check, brief operating instructions. (excl.: unpacking, setup, controller instructions, programming, installation work)

  • Art. No.: DL10-0100
- +
  • Designation:

    Unit instructions

  • Description:

    Instruction regarding operating principle and basic functions of the unit, operation of the control electronics including programming

  • Art. No.: DL10-0500
- +
  • Designation:

    Warranty extension from 2 to 3 years

  • Description:

    The warranty is extended from 2 to 3 years from the delivery date, wear parts are excluded

  • Art. No.: DL00-6041
- +
  • Designation:

    Warranty extension from 2 to 5 years

  • Description:

    The warranty is extended from 2 to 5 years from the delivery date, wear parts are excluded

  • Art. No.: DL00-6042
- +
Options and Accessories

Complementary to our products we offer a broad range of options and accessories - from access ports and to racks to documentation and software.

Please select a model to get an overview of all available options and accessories for this product:

Downloads

FDL series

  • Category: Operating Manuals
  • File type / size PDF (5.63 MB)

Safety drying chambers (FDL series) - BINDER chambers ensure quality Car manufacturer in Lower Bavaria

  • Category: Case Studies
  • File type / size PDF (134.33 kB)

Good Laboratory Practice Your checklist for GLP-compliant research and development

  • Category: White paper
  • File type / size PDF (808.38 kB)

Validation and Qualification In the regulated environment

  • Category: White paper
  • File type / size PDF (392.80 kB)

BINDER Service 100 % performance and availability

  • Category: Brochures
  • File type / size PDF (330.01 kB)

BINDER INDIVIDUAL Series production devices for special requirements

  • Category: Brochures
  • File type / size PDF (712.27 kB)

Safety drying chambers FDL series

  • Category: Brochures
  • File type / size PDF (1.35 MB)

Drying chambers for limited quantities of solvent

BINDER safety drying chambers are extremely accurate and ensure that drying is quick and even. With the option of operation at temperatures ranging up to 350 °C, these drying chambers can meet different requirements and are suitable for a wide range of applications. In its FDL series, BINDER has developed drying chambers for limited quantities of solvent, which provide the ideal environment for all samples containing solvents.
The FDL series includes drying chambers with a highly efficient filter cartridge and symmetrical air flow with defined flow rates. The cartridge can be replaced, guaranteeing high levels of operational safety along with the electronic fresh air monitoring system. The drying chambers operate with absolute temperature accuracy, even with high ventilation, thereby providing the basis for high-quality results and reproducible tests. The patented APT.line™ preheating chamber technology ensures that temperature distribution is homogeneous inside the drying chambers and test conditions are consistent across the entire usable space, regardless of the amount or size of the sample.

Drying chambers with maximum safety levels and ease of handling

BINDER drying chambers in the FDL series are the combination of maximum operational safety and consistent, reliable test conditions with ease of operation. Heat dissipation is minimal thanks to the chambers' 60-mm-thick insulation and the tight housing door is fitted with a 2-point door closure. The entire chamber interior is made of stainless steel, allowing the usable space to be cleaned thoroughly in no time. This is also helped by the fact that there are no built-in fixtures, as BINDER drying chambers are equipped with two chrome-plated racks instead.
The safety drying chambers in the FDL series are the number one choice for samples containing solvents.