Model KBF 1020 | Humidity test chambers with large temperature / humidity range
Benefits
- Safe thanks to climatic homogeneity that far exceeds the accuracy required by ICH guidelines, even with a fully loaded unit.
- Reliable thanks to failsafe operation without compromise. The interior and Longlife evaporator plate are made entirely from stainless steel.
- Smart, as a wide range of accessories makes it highly compatible for adaptation to specific customer requirements.
- Economical thanks to maximum effective volume which allows for 30% larger load compared to the competition.
Product description
The BINDER KBF is the specialist for unconditionally reliable stability testing and precise maintenance of constant climate conditions. From programming to documentation, this humidity test chamber meets all critical requirements.
Important characteristics
- Temperature range: 0 °C to +70 °C
- Humidity range: 10 % to 80 % RH
- APT.line™ preheating chamber technology
- Humidity regulation with capacitive humidity sensor and vapor humidification
- Intuitive touchscreen controller with time-segment and real-time programming
- BINDER Multi Management Software APT-COM™ Basic Edition
- Internal data logger, measured values can be read out in open format via USB
- Unit self-test for comprehensive status analysis
- Tight-sealing inner door made of safety glass (ESG)
- Avoidance of glass corrosion by special TIMELESS coating
- Inner chamber made of stainless steel
- 2 stainless steel racks
- Access port with silicone plug, 30 mm, left
- 4 stable castors, two with brakes, from 240 liters
- Class 3.1 independent temperature safety device (DIN 12880) with visual and audible temperature alarm
- Computer interface: Ethernet
- Door heating
Technical specifications
Designation | KBF1020-230V | KBF1020-240V |
Option model | Standard | Standard |
Article Number | 9020-0326 | 9020-0327 |
Max. heat compensation at 40°C | 600 W | 600 W |
Temperature range with humidity | 10...70 °C | 10...70 °C |
Humidity range | 10...80 % r.F. | 10...80 % r.F. |
Temperature uniformity at 25°C and 60% RH | 0.2 ± K | 0.2 ± K |
Temperature uniformity at 40°C and 75% RH | 0.2 ± K | 0.2 ± K |
Temperature fluctuation at 25°C and 60% RH | 0.1 ± K | 0.1 ± K |
Temperature fluctuation at 40°C and 75% RH | 0.1 ± K | 0.1 ± K |
Humidity fluctuation at 40°C and 75% RH | 1,5 ± % r.F. | 1,5 ± % r.F. |
Recovery time after door was opened for 30 s at 25°C and 60% RH | 11 min | 11 min |
Recovery time after door was opened for 30 s at 40°C and 75% RH | 12 min | 12 min |
Interior volume | 1020 L | 1020 L |
Innenraum: Breite | 973 mm | 973 mm |
Innenraum: Höhe | 1250 mm | 1250 mm |
Innenraum: Tiefe | 836 mm | 836 mm |
Permitted load | 150 kg | 150 kg |
Load per rack | 45 kg | 45 kg |
Inner doors | 2 | 2 |
Unit doors | 2 | 2 |
Wall clearance back | 100 mm | 100 mm |
Wall clearance sidewise | 100 mm | 100 mm |
Width net | 1250 mm | 1250 mm |
Height net | 1925 mm | 1925 mm |
Depth net | 1145 mm | 1145 mm |
Net weight of the unit (empty) | 379 kg | 379 kg |
Rated Voltage | 200...230 V | 200...240 V |
Power frequency | 50/60 Hz | 50/60 Hz |
Nominal power | 3,1 kW | 3,1 kW |
Unit fuse | 16 A | 16 A |
Phase (Nominal voltage) | 1~ | 1~ |
Energy consumption at 40°C and 75% RH | 650 Wh/h | 650 Wh/h |
Sound-pressure level | 56 dB(A) | 56 dB(A) |
Number of shelves (std./max.) | 2/15 | 2/15 |