Drying and heating chambers
E 28

Model E 28 | Drying and heating chambers with mechanical adjustment
- Temperature range: +60 °C to +230 °C
- Adjustable exhaust air flap
- Hydro-mechanical thermostat
- Class 1 temperature limitation device (Model E028-230V-T)
- Timer 0 – 120 min
ED 56

Model ED 56 | Drying and heating chambers with natural convection
- Temperature range: +5°C above ambient temperature to +300 °C
- Natural convection
- Controller with LCD display
- Electromechanical control of the exhaust air flap
- Class 2 integrated independent adjustable temperature safety device (DIN 12880) with visual alarm
- Excellent temporal and spatial temperature accuracy
- Up to 30% lower energy consumption compared to conventional units on the market
ED 115

Model ED 115 | Drying and heating chambers with natural convection
- Temperature range: +5°C above ambient temperature to +300 °C
- Natural convection
- Controller with LCD display
- Electromechanical control of the exhaust air flap
- Class 2 integrated independent adjustable temperature safety device (DIN 12880) with visual alarm
- Excellent temporal and spatial temperature accuracy
- Up to 30% lower energy consumption compared to conventional units on the market
ED 260

Model ED 260 | Drying and heating chambers with natural convection
- Temperature range: +5°C above ambient temperature to +300 °C
- Natural convection
- Controller with LCD display
- Electromechanical control of the exhaust air flap
- Class 2 integrated independent adjustable temperature safety device (DIN 12880) with visual alarm
- Excellent temporal and spatial temperature accuracy
- Up to 30% lower energy consumption compared to conventional units on the market
ED 720

Model ED 720 | Drying and heating chambers with natural convection
- Temperature range: +5°C above ambient temperature to +300 °C
- Natural convection
- Controller with LCD display
- Electromechanical control of the exhaust air flap
- Class 2 integrated independent adjustable temperature safety device (DIN 12880) with visual alarm
- Excellent temporal and spatial temperature accuracy
- Up to 30% lower energy consumption compared to conventional units on the market
ED 23

Model ED 23 | Drying and heating chambers with natural convection
- Temperature range: +5°C above ambient temperature to +300 °C
- Natural convection
- Adjustable exhaust air flap
- Controller with timer functions
- Class 2 independent adjustable temperature safety device (DIN 12880) with visual alarm
ED 400

Model ED 400 | Drying and heating chambers with natural convection
- Temperature range: +5°C above ambient temperature to +300 °C
- Natural convection
- Adjustable exhaust air flap
- Controller with timer functions
- Class 2 independent adjustable temperature safety device (DIN 12880) with visual alarm
ED-S 56

Model ED-S 56 | Drying and heating chambers with natural convection
- Temperature range: +7°C above ambient temperature to +250 °C
- APT.line™ preheating chamber technology
- Natural convection
- Adjustable exhaust air flap
- Controller with timer function
ED-S 115

Model ED-S 115 | Drying and heating chambers with natural convection
- Temperature range: +7°C above ambient temperature to +250 °C
- APT.line™ preheating chamber technology
- Natural convection
- Adjustable exhaust air flap
- Controller with timer function
FD 56

Model FD 56 | Drying and heating chambers with forced convection
- Temperature range: +10°C above ambient temperature to +300 °C
- Forced convection
- Controller with LCD display
- Electromechanical control of the exhaust air flap
- Class 2 integrated independent adjustable temperature safety device (DIN 12880) with visual alarm
- Excellent temporal and spatial temperature accuracy
- Up to 30% lower energy consumption compared to conventional units on the market
FD 115

Model FD 115 | Drying and heating chambers with forced convection
- Temperature range: +10°C above ambient temperature to +300 °C
- Forced convection
- Controller with LCD display
- Electromechanical control of the exhaust air flap
- Class 2 integrated independent adjustable temperature safety device (DIN 12880) with visual alarm
- Excellent temporal and spatial temperature accuracy
- Up to 30% lower energy consumption compared to conventional units on the market
FD 260

Model FD 260 | Drying and heating chambers with forced convection
- Temperature range: +10°C above ambient temperature to +300 °C
- Forced convection
- Controller with LCD display
- Electromechanical control of the exhaust air flap
- Class 2 integrated independent adjustable temperature safety device (DIN 12880) with visual alarm
- Excellent temporal and spatial temperature accuracy
- Up to 30% lower energy consumption compared to conventional units on the market
FD 720

Model FD 720 | Drying and heating chambers with forced convection
- Temperature range: +12°C above ambient temperature to +300 °C
- Forced convection
- Controller with LCD display
- Electromechanical control of the exhaust air flap
- Class 2 integrated independent adjustable temperature safety device (DIN 12880) with visual alarm
- Excellent temporal and spatial temperature accuracy
- Up to 30% lower energy consumption compared to conventional units on the market
FD 23

Model FD 23 | Drying and heating chambers with forced convection
- Temperature range: +5°C above ambient temperature to +300 °C
- Forced convection
- Adjustable exhaust air flap
- Controller with timer functions
- Class 2 independent adjustable temperature safety device (DIN 12880) with visual alarm
FD-S 115

Model FD-S 115 | Drying and heating chambers with forced convection
- Temperature range: +10°C above ambient temperature to +250 °C
- APT.line™ preheating chamber technology
- Forced convection
- Adjustable exhaust air flap
- Controller with timer function
FD-S 56

Model FD-S 56 | Drying and heating chambers with forced convection
- Temperature range: +10°C above ambient temperature to +250 °C
- APT.line™ preheating chamber technology
- Forced convection
- Adjustable exhaust air flap
- Controller with timer function
FED 56

Model FED 56 | Drying and heating chambers with forced convection and enhanced timer functions
- Temperature range: +10°C above ambient temperature to +300 °C
- Adjustable fan speed
- Controller with LCD display and enhanced time functions
- Electromechanical control of the exhaust air flap
- Class 2 integrated independent adjustable temperature safety device (DIN 12880) with visual alarm
- Ethernet interface
- Up to 30% lower energy consumption compared to conventional units on the market
FED 115

Model FED 115 | Drying and heating chambers with forced convection and enhanced timer functions
- Temperature range: +10°C above ambient temperature to +300 °C
- Adjustable fan speed
- Controller with LCD display and enhanced time functions
- Electromechanical control of the exhaust air flap
- Class 2 integrated independent adjustable temperature safety device (DIN 12880) with visual alarm
- Ethernet interface
- Up to 30% lower energy consumption compared to conventional units on the market
FED 260

Model FED 260 | Drying and heating chambers with forced convection and enhanced timer functions
- Temperature range: +10°C above ambient temperature to +300 °C
- Adjustable fan speed
- Controller with LCD display and enhanced time functions
- Electromechanical control of the exhaust air flap
- Class 2 integrated independent adjustable temperature safety device (DIN 12880) with visual alarm
- Ethernet interface
- Up to 30% lower energy consumption compared to conventional units on the market
FED 720

Model FED 720 | Drying and heating chambers with forced convection and enhanced timer functions
- Temperature range: +12°C above ambient temperature to +300 °C
- Adjustable fan speed
- Controller with LCD display and enhanced time functions
- Electromechanical control of the exhaust air flap
- Class 2 integrated independent adjustable temperature safety device (DIN 12880) with visual alarm
- Ethernet interface
- Up to 30% lower energy consumption compared to conventional units on the market
FED 400

Model FED 400 | Drying and heating chambers with forced convection and enhanced timer functions
- Temperature range: +5°C above ambient temperature to +300 °C
- Adjustable fan speed
- Adjustable exhaust air flap
- Controller with expanded timer functions
- Class 2 independent adjustable temperature safety device (DIN 12880) with visual alarm
- Computer interface: RS 422