Benefits
Important characteristics
Optional equipment
Details of the model
Select version
Technical data
The PDF data sheet contains technical data, options & accessories as well as services.
Downloads
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
Rated voltage | Option model | Version | Art. No. | Selection | Bookmark | |
---|---|---|---|---|---|---|
Model VDL 115 | ||||||
200…230 V 1~ 50/60 Hz | ||||||
Standard |
VDL115-230V | 9630-0011 | + | |||
100…120 V 1~ 50/60 Hz | ||||||
Standard |
VDL115UL-120V | 9630-0015 | + |
Designation | Description | Art. No. | Bookmark | |||
---|---|---|---|---|---|---|
Additional universal ventilation | ||||||
Additional universal connection for ventilation with ambient air or inert gas. Flow limiter thread (RP"), and connection with 3/8" male thread. |
8612-0001 | + | ||||
Analog output 4-20 mA | ||||||
for temperature and pressure values (output not adjustable) |
8612-0004 | + | ||||
Calibration certificate, expanded | ||||||
for temperature; for extending the measurement in center of chamber to include another test temperature |
8012-1127 | + | ||||
Calibration certificate, pressure | ||||||
Calibration of the pressure display to a specified value, including certificate |
8012-2021 | + | ||||
Extension of the calibration of the pressure display by another pressure value, including certificate |
8012-2022 | + | ||||
Calibration certificate, temperature | ||||||
temperature measurement incl. certificate, 15- 18 measuring points at specified temperature |
8012-0919 | + | ||||
for temperature, measurement in center of chamber at specified temperature |
8012-1145 | + | ||||
temperature measurement incl. certificate, 9 measuring points at specified temperature |
8012-0916 | + | ||||
Door gasket | ||||||
made of FKM, silicone-free |
8612-0009 | + | ||||
Door lock | ||||||
lockable door handle |
8612-0002 | + | ||||
Expansion racks | ||||||
stainless steel expansion rack instead of standard aluminum expansion rack, incl. calibration |
8612-0013 | + | ||||
|
8009-1091 | + | ||||
aluminum |
8012-2057 | + | ||||
pH-neutral detergent | ||||||
concentrated, for gentle remove of residual contaminants; 1 kg |
1002-0016 | + | ||||
Pump chamber with vacuum pump VAP 5 | ||||||
Pump chamber for mounting vacuum pumps including chemical membrane pump VAP 5 with nominal air flow 3.6 m³/hour, final pressure 3 mbar, with separator and emission condenser, suitable for flammable solvents and vacuum pump connection kit (ATEX). |
8012-2063 | + | ||||
Qualification documents | ||||||
IQ/OQ/PQ documents – supporting documents for validation performed by customers, according to customer requirements, PQ section added to qualification folder IQ/OQ; parameters: temperature, CO₂, O₂ – or pressure, depending on unit |
7057-0005 | + | ||||
IQ/OQ/PQ documents – supporting documents for validation performed by customers, according to customer requirements, PQ section added to qualification folder IQ/OQ; parameters: temperature, CO₂, O₂ – or pressure, depending on unit |
7007-0005 | + | ||||
IQ/OQ documents – supporting documents for validation performed by customers, consisting of: IQ/OQ checklists incl. calibration guide and comprehensive unit documentation; parameters: temperature, CO₂, O₂, pressure, depending on unit |
7057-0001 | + | ||||
IQ/OQ documents – supporting documents for validation performed by customers, consisting of: IQ/OQ checklists incl. calibration guide and comprehensive unit documentation; parameters: temperature, CO₂, O₂, pressure, depending on unit |
7007-0001 | + | ||||
Temperature measurement of the specimen | ||||||
with flexible Pt 100 sensor and digital specimen temperature display |
8612-0006 | + | ||||
Universal access port | ||||||
Additional DN 40 small flange universal access port with blind flange, for positioning sensors or supply lines in the chamber. |
8612-0003 | + | ||||
Vacuum pump connection kit (ATEX) | ||||||
For vacuum pump VAP 5, consisting of 1.5 m metal hose, clamping ring, internal centering ring and protective covers |
8012-2029 | + | ||||
Vacuum pump VAP 5 | ||||||
Chemical membrane pump with nominal air flow 3.9 m³/h, final pressure 3 mbar, with separator and emission condenser, suitable for flammable solvents |
5013-0220 | + | ||||
Chemical membrane pump with nominal air flow 3.9 m³/h, final pressure 3 mbar, with separator and emission condenser, suitable for flammable solvents |
5013-0221 | + | ||||
WLAN kit | ||||||
The kit contains a client bridge that establishes a wireless connection between BINDER units and APT-COM4, LIMS, or customer-specific software via an Ethernet interface. It provides an alternative solution in situations where units need to be positioned in locations without an on-site Ethernet connection. In secured networks, installation and configuration must be performed by the customer’s IT service. |
8500-0164 | + |
Designation | Description | Art. No. | Bookmark | |||
---|---|---|---|---|---|---|
1-year warranty extension |
The warranty is extended by 1 year from the delivery date, wear parts are excluded |
DL50-0020 | + | |||
BRONZE 3-year maintenance contract |
Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts |
DL20-0710 | + | |||
Calibration certificate, temperature |
Calibration of one (1) test temperature specified by the user in center of chamber, including certificate |
DL30-0101 | + | |||
Calibration certificate, temperature |
Extension of calibration of one (1) additional test temperature specified by the user in the center of the usable space, including certificate |
DL30-0102 | + | |||
Execution of IQ/OQ |
Execution of IQ/OQ in accordance with qualification folder |
DL42-0300 | + | |||
Execution of IQ/OQ/PQ |
Execution of IQ/OQ/PQ in accordance with qualification folder |
DL44-0500 | + | |||
GOLD 3-year maintenance contract |
Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts, testing of all key functions, replacement of wear parts, calibration of one temperature/humidity/pressure value, including certificate |
DL20-0930 | + | |||
Maintenance |
One-off maintenance service in accordance with maintenance schedule. Visual inspection of mechanical and electrical components, testing of all key functions. Calibration of a test temperature specified by the user in center of usable space without certificate |
DL20-0500 | + | |||
Maintenance |
One-off maintenance service in accordance with maintenance schedule. Visual inspection of mechanical and electrical components, testing of all key functions. Calibration of a test temperature specified by the user in center of usable space without certificate |
DL20-0400 | + | |||
Pressure calibration |
Digital pressure display calibration at a specified test pressure of 20–900 mbar, including certificate |
DL30-0410 | + | |||
Pressure calibration |
Digital pressure display calibration at a specified test pressure of 20–900 mbar, including certificate |
DL30-0411 | + | |||
Safety test |
Testing of ATEX-specific safety systems: inert gas flushing and safety temperature shut-off. Testing of the specified systems also forms part of the more extensive maintenance service (DL20-0500) |
DL34-0000 | + | |||
SILVER 3-year maintenance contract |
Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts, testing of all key functions, calibration of one test temperature specified by the user in the center of the usable space, without certificate |
DL20-0820 | + | |||
Temperature measurement, 15 measuring points |
Temperature measurement with 15 measuring points with a set value specified by the user, including certificate |
DL30-0218 | + | |||
Temperature measurement, 9 measuring points |
Temperature measurement with 9 measuring points with a set value specified by the user, including certificate |
DL30-0109 | + | |||
Unit commissioning |
Connect the unit to the customer-side connections (electricity, water, wastewater, gas), basic functions check, brief operating instructions. (excl.: unpacking, setup, controller instructions, programming, installation work) |
DL10-0100 | + | |||
Unit instructions |
Instruction regarding operating principle and basic functions of the unit, operation of the control electronics including programming |
DL10-0500 | + |
Designation |
VDL115-230V¹ |
VDL115UL-120V¹ |
---|---|---|
Option model | Standard | Standard |
Order number | 9630-0011 | 9630-0015 |
Data | ||
Serie | VDL | VDL |
Performance Data Temperature | ||
Heating-up time to 100 °C [min] | 170 | 170 |
Temperature fluctuation [± K] | 0.1 | 0.1 |
Temperature range +10 °C above ambient temperature to [°C] | 110 | 110 |
Temperature range +9 °C above ambient temperature to [°C] | 110 | 110 |
Temperature variation at 100 °C [± K] | 2.9 | 2.9 |
Vacuum Data | ||
Leak rate [bar/h] | 0.01 | 0.01 |
Permitted end vacuum [mbar] | 0.01 | 0.01 |
Electrical data | ||
Nominal power [kW] | 1.6 | 1.6 |
Phase (Nominal voltage) | 1~ | 1~ |
Power frequency [Hz] | 50/60 | 50/60 |
Rated Voltage [V] | 200…230 | 100…120 |
Unit fuse [A] | 10 | 20 |
Connections | ||
Measuring access port with small flange [DN mm] | 16 | 16 |
Universal connection for air / inert gas with flow limiter thread (RP") 3/8 | 3/8 | 3/8 |
Vacuum connection with small flange [DN mm] | 16 | 16 |
Doors | ||
Unit doors | 1 | 1 |
Housing dimensions not incl. fittings and connections | ||
Depth net [mm] | 581 | 581 |
Height net [mm] | 942 | 942 |
Width net [mm] | 743 | 743 |
Internal Dimensions | ||
Depth [mm] | 460 | 460 |
Height [mm] | 506 | 506 |
Width [mm] | 506 | 506 |
Measures | ||
Interior volume [L] | 119 | 119 |
Load per rack [kg] | 20 | 20 |
Net weight of the unit (empty) [kg] | 158 | 158 |
Permitted load [kg] | 70 | 70 |
Viewing window height [mm] | 468 | 468 |
Viewing window width [mm] | 525 | 525 |
Wall clearance back [mm] | 100 | 100 |
Wall clearance sidewise [mm] | 70 | 70 |
Environment-specific data | ||
Sound-pressure level [dB(A)] | 40 | 40 |
Fixtures | ||
Number of shelves (std./max.) | 2/6 | 2/6 |
Performance Data Temperature | ||
Heating-up time to 100 °C [min] | 170 | 170 |
Temperature fluctuation [± K] | 0.1 | 0.1 |
Temperature range +10 °C above ambient temperature to [°C] | 110 | 110 |
Temperature range +9 °C above ambient temperature to [°C] | 110 | 110 |
Temperature variation at 100 °C [± K] | 2.9 | 2.9 |
Vacuum Data | ||
Leak rate [bar/h] | 0.01 | 0.01 |
Permitted end vacuum [mbar] | 0.01 | 0.01 |
Electrical data | ||
Nominal power [kW] | 1.6 | 1.6 |
Phase (Nominal voltage) | 1~ | 1~ |
Power frequency [Hz] | 50/60 | 50/60 |
Rated Voltage [V] | 200…230 | 100…120 |
Unit fuse [A] | 10 | 20 |
Connections | ||
Measuring access port with small flange [DN mm] | 16 | 16 |
Universal connection for air / inert gas with flow limiter thread (RP") 3/8 | 3/8 | 3/8 |
Vacuum connection with small flange [DN mm] | 16 | 16 |
Doors | ||
Unit doors | 1 | 1 |
Housing dimensions not incl. fittings and connections | ||
Depth net [in] | 22.89 | 22.89 |
Height net [in] | 37.11 | 37.11 |
Width net [in] | 29.27 | 29.27 |
Internal Dimensions | ||
Depth [in] | 18.12 | 18.12 |
Height [in] | 19.94 | 19.94 |
Width [in] | 19.94 | 19.94 |
Measures | ||
Interior volume [cu.ft.] | 4.2 | 4.2 |
Load per rack [lbs] | 44 | 44 |
Net weight of the unit (empty) [lbs] | 348 | 348 |
Permitted load [lbs] | 154 | 154 |
Viewing window height [in] | 18.44 | 18.44 |
Viewing window width [in] | 20.69 | 20.69 |
Wall clearance back [in] | 3.94 | 3.94 |
Wall clearance sidewise [in] | 2.76 | 2.76 |
Environment-specific data | ||
Sound-pressure level [dB(A)] | 40 | 40 |
Fixtures | ||
Number of shelves (std./max.) | 2/6 | 2/6 |
Category | Title | File type / size | Download |
---|---|---|---|
Data Sheets |
VDL 115 |
PDF (114.67 kB) | > |
Operating Manuals |
VAP 5 Vacuum Pumps For vacuum drying oven VDL |
PDF (6.55 MB) | > |
Operating Manuals |
VDL series |
PDF (11.02 MB) | > |
Technical Drawings |
Version VDL115-230V |
PDF (289.44 kB) | > |
Technical Drawings |
Version VDL115-120V |
PDF (299.15 kB) | > |
Case Studies |
Vacuum drying chambers (VD | VDL series) - BINDER chambers play a role in smartphone production GEWO Feinmechanik GmbH |
PDF (258.36 kB) | > |
Case Studies |
Vacuum drying chambers (VD | VDL series) - How Aesculap uses BINDER chambers for quality testing B | Braun Aesculap AG |
PDF (180.57 kB) | > |
Case Studies |
Vacuum drying chambers (VDL series) - Quality testing: Nutriswiss tests oil in BINDER vacuum drying chamber Nutriswiss AG |
PDF (416.93 kB) | > |
White paper |
Good Laboratory Practice Your checklist for GLP-compliant research and development |
PDF (808.38 kB) | > |
White paper |
Validation and Qualification In the regulated environment |
PDF (392.80 kB) | > |
Options & Accessories |
VAP 5 vacuum pump ATEX chemical membrane pump VDL series |
PDF (144.89 kB) | > |
Brochures |
BINDER INDIVIDUAL Series production devices for special requirements |
PDF (712.27 kB) | > |
Brochures |
Vacuum drying chambers VD | VDL series |
PDF (1.38 MB) | > |
Buyer´s Guide |
Vacuum drying chambers 4 key factors to consider when buying vacuum drying chambers |
PDF (1.97 MB) | > |