Model VD 56 | Vacuum drying chamber for non-flammable solvents

  • Fast, gentle drying
  • Optimum heat transfer through large thermal conducting plates
  • Safe work thanks to proven safety concept
  • Also option of modular complete system with vacuum pump and pump chamber

Configure your product with options and accessories and request it directly here.

Technical specifications

DesignationVD056-230V¹VD056UL-120V¹
Option modelStandardStandard
Order number9630-00029630-0006
Data
SerieVDVD
Performance Data Temperature
Heating-up time to 100 °C [min]8080
Temperature fluctuation [± K]0.10.1
Temperature range +10 °C above ambient temperature to [°C]220220
Temperature range +9 °C above ambient temperature to [°C]220220
Temperature variation at 100 °C [± K]1.21.2
Vacuum Data
Leak rate [bar/h]0.010.01
Electrical data
Nominal power [kW]1.41.4
Phase (Nominal voltage)1~1~
Power frequency [Hz]50/6050/60
Rated Voltage [V]200…230100…120
Unit fuse [A]816
Connections
Compressed air connection for pressure-encapsulation [NW]55
Measuring access port with small flange [DN mm]1616
Universal connection for air / inert gas with flow limiter thread (RP") 3/83/83/8
Vacuum connection with small flange [DN mm]1616
Doors
Unit doors11
Housing dimensions not incl. fittings and connections
Depth net [mm]461461
Height net [mm]815815
Width net [mm]638638
Internal Dimensions
Depth [mm]343343
Height [mm]400400
Width [mm]400400
Measures
Interior volume [L]5555
Load per rack [kg]2020
Net weight of the unit (empty) [kg]95101
Permitted load [kg]6060
Viewing window height [mm]420420
Viewing window width [mm]420420
Wall clearance back [mm]100100
Wall clearance sidewise [mm]7070
Environment-specific data
Sound-pressure level [dB(A)]4040
Fixtures
Number of shelves (std./max.)1/51/5
Performance Data Temperature
Heating-up time to 100 °C [min]8080
Temperature fluctuation [± K]0.10.1
Temperature range +10 °C above ambient temperature to [°C]220220
Temperature range +9 °C above ambient temperature to [°C]220220
Temperature variation at 100 °C [± K]1.21.2
Vacuum Data
Leak rate [bar/h]0.010.01
Electrical data
Nominal power [kW]1.41.4
Phase (Nominal voltage)1~1~
Power frequency [Hz]50/6050/60
Rated Voltage [V]200…230100…120
Unit fuse [A]816
Connections
Compressed air connection for pressure-encapsulation [NW]55
Measuring access port with small flange [DN mm]1616
Universal connection for air / inert gas with flow limiter thread (RP") 3/83/83/8
Vacuum connection with small flange [DN mm]1616
Doors
Unit doors11
Housing dimensions not incl. fittings and connections
Depth net [in]18.1618.16
Height net [in]32.1132.11
Width net [in]25.1425.14
Internal Dimensions
Depth [in]13.5113.51
Height [in]15.7615.76
Width [in]15.7615.76
Measures
Interior volume [cu.ft.]1.91.9
Load per rack [lbs]4444
Net weight of the unit (empty) [lbs]209223
Permitted load [lbs]132132
Viewing window height [in]16.5516.55
Viewing window width [in]16.5516.55
Wall clearance back [in]3.943.94
Wall clearance sidewise [in]2.762.76
Environment-specific data
Sound-pressure level [dB(A)]4040
Fixtures
Number of shelves (std./max.)1/51/5

Downloads

Data Sheets VD 56

pdf

Operating Manuals VD series

pdf

Operating Manuals Vacuum pump VAP1 | VAP2 For vacuum drying oven VD

pdf

Technical Drawings Version VD056-230V

pdf

Technical Drawings Version VD056-120V

pdf

Technical Drawings Vacuum pump VAP 2 5013-0218

pdf

Technical Drawings Vacuum pump VAP 1 5013-0217

pdf

Brochures BINDER INDIVIDUAL Series production devices for special requirements

pdf

Brochures Vacuum drying chambers VD | VDL series

pdf