Series VD | Vacuum drying chambers for non-flammable solvents

BINDER’s VD series vacuum drying chambers deliver impressive performance through their precise temperature control and gentle drying. The patented expansion rack technology from BINDER also optimizes heat transfer. The shelves can be repositioned for flexible placement and the interior of the chamber is easy to clean.

Benefits

  • Fast, gentle drying
  • Optimum heat transfer through large thermal conducting plates
  • Safe work thanks to proven safety concept
  • Also option of modular complete system with vacuum pump and pump chamber

Important characteristics

  • Temperature range: +9 °C above ambient temperature to +220 °C
  • Controller with digital display of pressure and temperature
  • Program-controlled drying monitoring with automatic ventilation at end of process
  • Internal data logger, measured values can be read out in open format via USB
  • 1 aluminum expansion rack, can be custom-positioned
  • Inert gas connection
  • Shatterproof, spring-mounted safety glass panel
  • Large viewing window with option of interior lighting
  • Computer interface: Ethernet
  • 2 relay outputs, 24 V DC (max. 0.4 A)

Optional equipment

  • Touchscreen Controller - Graphical display of main process parameter
  • Expansion racks - Choice of aluminum or stainless steel racks depending on the application requirements
  • Analogue output for temperature and pressure signals - for external monitoring and evaluation of the process parameters, integration into in-house systems is possible
  • Universal ventilation - Selection of different ventilation by air or inert gas
  • Universal access port DN 40 - for the introduction of external measuring devices
  • Multi Management Software APT-COM - Manage, record and document device parameters
  • Services - extensive services ensure correct device function
Models
  • Model VD 23
  • Housing dimensions not incl. fittings and connections - W x H x D [mm]: 523 x 698 x 413
  • Internal dimension W x H x D [mm]: 285 x 285 x 295
  • Net weight [kg]: 68
  • Interior volume [L]: 24
  • Bookmark +
  • Model VD 56
  • Housing dimensions not incl. fittings and connections - W x H x D [mm]: 638 x 815 x 461
  • Internal dimension W x H x D [mm]: 400 x 400 x 343
  • Net weight [kg]: 101
  • Interior volume [L]: 55
  • Bookmark +
  • Model VD 115
  • Housing dimensions not incl. fittings and connections - W x H x D [mm]: 743 x 942 x 581
  • Internal dimension W x H x D [mm]: 506 x 506 x 460
  • Net weight [kg]: 146
  • Interior volume [L]: 119
  • Bookmark +
Technical data

Please select a model to view technical data:

Services
RRP* [?] Merken
  • Designation:

    Calibration certificate, temperature

  • Description:

    Extension of calibration of one (1) additional test temperature specified by the user in the center of the usable space, including certificate

  • Art. No.: DL30-0102
- +
  • Designation:

    Calibration certificate, temperature

  • Description:

    Calibration of one (1) test temperature specified by the user in center of chamber including certificate

  • Art. No.: DL30-0101
- +
  • Designation:

    Execution of IQ/OQ

  • Description:

    Execution of IQ/OQ in accordance with qualification folder

  • Art. No.: DL42-0300
- +
  • Designation:

    Execution of IQ/OQ/PQ

  • Description:

    Execution of IQ/OQ/PQ in accordance with qualification folder

  • Art. No.: DL44-0500
- +
  • Designation:

    Maintenance

  • Description:

    Maintenance service in accordance with maintenance schedule. Visual inspection of mechanical and electrical components, testing of all key functions. Calibration of a test temperature specified by the user in center of chamber without certificate

  • Art. No.: DL20-0400
- +
  • Designation:

    Pressure calibration

  • Description:

    Digital pressure display calibration at a specified test pressure of 20–900 mbar, including certificate

  • Art. No.: DL32-0000
- +
  • Designation:

    Temperature measurement, 15 measuring points

  • Description:

    Temperature measurement with 15 measuring points with a set value specified by the user, including certificate

  • Art. No.: DL30-0218
- +
  • Designation:

    Temperature measurement, 9 measuring points

  • Description:

    Temperature measurement with 9 measuring points with a set value specified by the user, including certificate

  • Art. No.: DL30-0109
- +
  • Designation:

    Unit commissioning

  • Description:

    Connect the unit to the customer-side connections (electricity, water, wastewater, gas), basic functions check, brief operating instructions. (excl.: unpacking, setup, controller instructions, programming, installation work)

  • Art. No.: DL10-0100
- +
  • Designation:

    Unit instructions

  • Description:

    Instruction regarding operating principle and basic functions of the unit, operation of the control electronics including programming

  • Art. No.: DL10-0500
- +
  • Designation:

    Warranty extension from 2 to 3 years

  • Description:

    The warranty is extended from 2 to 3 years from the delivery date, wear parts are excluded

  • Art. No.: DL00-8041
- +
  • Designation:

    Warranty extension from 2 to 5 years

  • Description:

    The warranty is extended from 2 to 5 years from the delivery date, wear parts are excluded

  • Art. No.: DL00-8042
- +
Options and Accessories

Complementary to our products we offer a broad range of options and accessories - from access ports and to racks to documentation and software.

Please select a model to get an overview of all available options and accessories for this product:

Downloads

VD series

  • Category: Operating Manuals
  • File type / size PDF (7.14 MB)

Vacuum drying chambers (VD | VDL series) - BINDER chambers play a role in smartphone production GEWO Feinmechanik GmbH

  • Category: Case Studies
  • File type / size PDF (258.36 kB)

Vacuum drying chambers (VD | VDL series) - How Aesculap uses BINDER chambers for quality testing B | Braun Aesculap AG

  • Category: Case Studies
  • File type / size PDF (180.57 kB)

Good Laboratory Practice Your checklist for GLP-compliant research and development

  • Category: White paper
  • File type / size PDF (808.38 kB)

Validation and Qualification In the regulated environment

  • Category: White paper
  • File type / size PDF (392.80 kB)

BINDER Service 100 % performance and availability

  • Category: Brochures
  • File type / size PDF (330.01 kB)

BINDER INDIVIDUAL Series production devices for special requirements

  • Category: Brochures
  • File type / size PDF (712.27 kB)

Vacuum drying chambers VD | VDL series

  • Category: Brochures
  • File type / size PDF (1.38 MB)

Vacuum drying chambers 4 key factors to consider when buying vacuum drying chambers

  • Category: Buyer´s Guide
  • File type / size PDF (1.97 MB)

Vacuum drying chambers for non-flammable solvents

When it comes to non-flammable solvents, BINDER supplies high-quality, innovative vacuum drying chambers, which can be used for effective yet gentle drying of the materials in question. Heat is transferred to the sample directly using heat conductor plates, with drying being homogeneous, quick, and free from condensation across the entire usable space.
Easy operation and outstanding process stability, combined with a unique safety concept, make BINDER vacuum drying chambers extremely safe. What’s more, the drying chambers in the VDL series are explosion-proof and suitable for drying combustible solvents. The stainless-steel coating of the drying chamber interior is corrosion-resistant and makes the units incredibly robust, durable, and easy to clean.

Vacuum drying chambers for effective and gentle drying

BINDER vacuum drying chambers for non-flammable solvents enable effective, gentle drying without residue and without damaging the material being dried. The drying chambers operate within a temperature range of between 10 °C above ambient temperature to 220 °C. The APT.line™ heating principle ensures homogeneous temperature distribution in the chamber interior. Safety is guaranteed by an extensive safety package that includes a shatterproof, spring-mounted safety glass panel. It is also possible to divert humidity away using inert gas that is guided into the vacuum drying chamber via the inert gas connection. The numerous adjustment options also make the vacuum drying chambers extremely easy to use.
If you are looking to dry samples evenly and gently on the basis of a reliable safety concept and with easy cleaning and handling, look no further than BINDER’s vacuum drying chambers for non-flammable solvents.