Series BF Avantgarde.Line | Standard-Incubators with forced convection

The BINDER incubator of the BF Avantgarde.Line series with forced convection is suitable for all gentle incubation applications, particularly under a full load and large batch throughputs. This incubator is extremely homogeneous and has quick recovery times.

Benefits

  • Excellent temporal and spatial temperature accuracy
  • High process reliability
  • 100 °C disinfection routine

Important characteristics

  • Temperature range (model 56 | 260): +7 °C above ambient temperature to +100 °C
  • Temperature range (model 115): +8 °C above ambient temperature to +100 °C
  • High temperature accuracy thanks to APT.line™ technology
  • Forced convection
  • Controller with LCD display
  • Electromechanical control of the exhaust air flap
  • Inner door made of tempered safety glass
  • 2 chrome-plated racks
  • Units up to 115 L are stackable
  • 4 stable castors, two with brakes, from 720 liters
  • Class 3.1 integrated independent temperature safety device (DIN 12880) with visual alarm
  • Ergonomic handle design
  • USB port for recording data
Models
  • Model BF 56
  • Housing dimensions not incl. fittings and connections - W x H x D [in]: 22.06 x 24.63 x 22.26
  • Internal dimension W x H x D [in]: 15.76 x 17.34 x 13.4
  • Net weight [lbs]: 88
  • Interior volume [cu.ft.]: 2.1
  • Bookmark +
  • Model BF 115
  • Housing dimensions not incl. fittings and connections - W x H x D [in]: 27.97 x 28.57 x 23.84
  • Internal dimension W x H x D [in]: 21.67 x 21.67 x 14.97
  • Net weight [lbs]: 123
  • Interior volume [cu.ft.]: 4
  • Bookmark +
  • Model BF 260
  • Housing dimensions not incl. fittings and connections - W x H x D [in]: 31.91 x 33.29 x 29.94
  • Internal dimension W x H x D [in]: 25.61 x 30.73 x 20.09
  • Net weight [lbs]: 187
  • Interior volume [cu.ft.]: 9.1
  • Bookmark +
  • Model BF 720
  • Housing dimensions not incl. fittings and connections - W x H x D [in]: 45.9 x 62.6 x 34.28
  • Internal dimension W x H x D [in]: 39.4 x 51.2 x 22.26
  • Net weight [lbs]: 366
  • Interior volume [cu.ft.]: 25.9
  • Bookmark +
Technical data

Please select a model to view technical data:

Services
MSRP* [?] Merken
  • Designation:

    Execution of IQ/OQ

  • Description:

    Execution of IQ/OQ in accordance with qualification folder

  • Art. No.: DL40-0100
- +
  • Designation:

    Execution of IQ/OQ/PQ

  • Description:

    Execution of IQ/OQ/PQ in accordance with qualification folder

  • Art. No.: DL44-0500
- +
  • Designation:

    Maintenance

  • Description:

    Maintenance service in accordance with maintenance schedule. Visual inspection of mechanical and electrical components, testing of all key functions. Calibration of a test temperature specified by the user in center of chamber without certificate

  • Art. No.: DL20-0200
- +
  • Designation:

    Temperature calibration

  • Description:

    Extension of calibration of one (1) additional test temperature specified by the user in the center of the usable space, including certificate

  • Art. No.: DL30-0102
- +
  • Designation:

    Temperature calibration

  • Description:

    Calibration of one (1) test temperature specified by the user in center of chamber including certificate

  • Art. No.: DL30-0101
- +
  • Designation:

    Temperature measurement, 18 measuring points

  • Description:

    Temperature measurement with 18 measuring points with a set value specified by the user, including certificate

  • Art. No.: DL30-0118
- +
  • Designation:

    Temperature measurement, 27 measuring points

  • Description:

    Temperature measurement with 27 measuring points with a set value specified by the user, including certificate

  • Art. No.: DL30-0127
- +
  • Designation:

    Temperature measurement, 9 measuring points

  • Description:

    Temperature measurement with 9 measuring points with a set value specified by the user, including certificate

  • Art. No.: DL30-0109
- +
  • Designation:

    Unit installation

  • Description:

    Connect the unit to the customer-side connections (electricity, water, wastewater, gas), basic functions check, brief operating instructions. (excl.: unpacking, setup, controller instructions, programming, installation work)

  • Art. No.: DL10-0100
- +
  • Designation:

    Unit instructions

  • Description:

    Instruction regarding operating principle and basic functions of the unit, operation of the control electronics including programming

  • Art. No.: DL10-0500
- +
Options and Accessories

Complementary to our products we offer a broad range of options and accessories - from access ports and to racks to documentation and software.

Please select a model to get an overview of all available options and accessories for this product:

Downloads

BD | BF | ED | FD | FED series Avantgarde.Line Models 56 | 115 | 260 | 720

  • Category: Operating Manuals
  • File type / size PDF (10.79 MB)

Standard incubators (BD series) - Eternal youth with new anti-wrinkle cream Princess Dr. med. Sarah von Isenburg

  • Category: Case Studies
  • File type / size PDF (762.42 kB)

Good Laboratory Practice Your checklist for GLP-compliant research and development

  • Category: White paper
  • File type / size PDF (808.38 kB)

Validation and Qualification In the regulated environment

  • Category: White paper
  • File type / size PDF (393.27 kB)

Standard-Incubators B | BD | BD-S | BF series

  • Category: Brochures
  • File type / size PDF (1.58 MB)

BINDER Service 100 % performance and availability

  • Category: Brochures
  • File type / size PDF (1.12 MB)

BINDER INDIVIDUAL Series production devices for special requirements

  • Category: Brochures
  • File type / size PDF (713.75 kB)

Incubators with forced convection for challenging incubation tasks

BINDER offers incubators to suit different laboratory requirements. Alongside incubators with mechanical adjustment, the Classic.Line also includes incubators with natural convection and, in the BF series, incubators with forced convection, which guarantee quick temperature equalization through forced convection after the chamber door has been opened.
Operating within a temperature range of between 5 °C and 100 °C, these incubators with forced convection all have an adjustable exhaust air flap and the fan speed can be adjusted on an individual basis. The proven APT.line™ preheating chamber technology and the cooling system guarantee maximum precision and results that are reproducible in every laboratory test.

Incubators with forced convection for precision, functionality, and usability

The BINDER BF series incubators with forced convection are also ideal for challenging incubation tasks, with safety and precision guaranteed even when fully loaded and under high batch throughputs. Operation with forced convection is unbelievably homogeneous, while the incubator also offers speedy recovery times. The incubator with forced convection boasts high usability thanks to its straightforward controller with timer functions. The units can be stacked on top of one another for an optimum ratio between use and space needed. Reliable decontamination is another advantage afforded by these incubators. The disinfection routine at 100 °C minimizes the risk of contamination, while the premium stainless steel inner chamber does not have any built-in fixtures, allowing for ease of cleaning.
This BINDER incubator with forced convection is energy efficient, so is also extremely economical during operation.