Model 720
Dimensions
Product image
Product image

Model BD 720 | Standard-Incubators with gravity convection

Benefits
  • Excellent temporal and spatial temperature accuracy
  • High process reliability
  • 100°C disinfection routine
     

Configure your product with options and accessories and request it directly here.

Product description

The BD Avantgarde.Line series is specially designed for gentle incubation of organisms, as well as conditioning of heat-sensitive media. The new design of the units and the homogeneous temperature distribution ensure the very best results.

Important characteristics

  • Temperature range: ambient temperature plus 5 °C to 100 °C
  • High temperature accuracy thanks to APT.line™ technology
  • Gravity convection
  • Controller with LCD display
  • Electromechanical control of the exhaust air flap
  • Inner door made of tempered safety glass
  • 2 chrome-plated racks
  • Class 3.1 integrated independent temperature safety device (DIN 12880) with visual alarm
  • Ergonomic handle design
  • USB port for recording data

Technical specifications

Data
DesignationBD720-230V

BD720UL-240V

Article Number9010-03319010-0332
Option model

Standard

Standard

Performance Data Temperature
Temperature range+5 °C above ambient temperature to 100 °C+5 °C above ambient temperature to 100 °C
Temperature uniformity at 37°C0.7 ± K0.7 ± K
Temperature uniformity at 100°C3.0 ± K3.0 ± K
Temperature fluctuation at 37°C0.1 ± K0.1 ± K
Temperature fluctuation at 100°C0.3 ± K0.3 ± K
Heating up time to 100°C90 min90 min
Heating up time to 37°C70 min70 min
Recovery time after door was opened for 30 s at 37°C23 min23 min
Electrical data
Rated Voltage230 V240 V
Power frequency50/60 Hz50/60 Hz
Nominal power1,65 kW1,75 kW
Unit fuse16,0 A16,0 A
Phase (Nominal voltage)1~1~
Dimensions and weights
Interior volume26 cu.ft.26 cu.ft.
Net weight of the unit (empty)373 lbs373 lbs
Load per rack99 lbs99 lbs
Permitted load694 lbs694 lbs
Wall clearance back6,3 in6,3 in
Wall clearance sidewise3,94 in3,94 in
Housing dimensions not incl. fittings and connections
Width net45.87 in45.87 in
Height net62.6 in62.6 in
Depth net34.25 in34.25 in
Internal Dimensions
Interior width37.8 in37.8 in
Interior height50.39 in50.39 in
Interior depth23.62 in23.62 in
Inner doors22
Unit doors22
Environment-specific data
Energy consumption at 100°C480 Wh/h480 Wh/h
Energy consumption at 37°C78 Wh/h78 Wh/h
Fixtures
Number of shelves (std./max.)2/162/16

Downloads

Standard-Incubators

B | BD | BD-S | BF series

pdf, 1.58 MB

Standard incubators (BD series) - Eternal youth with new anti-wrinkle cream

Princess Dr. med. Sarah von Isenburg

pdf, 762.42 KB

BD | BF | ED | FD | FED series

pdf, 18.66 MB

Quick Start Guide BD | BF | ED | FD | FED series

pdf, 1.65 MB

Data Sheet Model BD 720

pdf, 370.75 KB

Options, Accessories, Services

Sorry, no result could be found. Check the spelling or use a new search term.

Rack

Max. load per rack 45 kg. chrome plated

8012-2045

Shelves

Rack - chrome plated

Rack

Max. load per rack 45 kg. stainless steel

8012-2174

Shelves

Rack - stainless steel

Shelf, perforated

Max. load per rack 40 kg. Stainless steel

8012-2182

Shelf

Shelf, perforated - Stainless steel

Rack, heavy load

Max. load per rack 70 kg. Stainless steel

8012-2186

Reinforced shelf racks

Rack, heavy load - Stainless steel

APT-COM™ 4 BASIC-Edition

For simple logging and documentation requirements with up to 5 networked units.. version 4, BASIC edition

9053-0039

Multi Management Software APT-COM™

APT-COM™ 4 BASIC-Edition - for simple logging and documentation requirements with up to 5 networked units.

APT-COM™ 4 PROFESSIONAL-Edition

Convenient unit and user management built on the BASIC edition. Suitable for networking up to 100 units.. version 4, PROFESSIONAL edition

9053-0040

Multi Management Software APT-COM™

APT-COM™ 4 PROFESSIONAL-Edition - convenient unit and user management built on the BASIC edition. Suitable for networking up to 100 units.

APT-COM™ 4 GLP-Edition

For working under GLP-compliant conditions. Measured values are documented in a tamper-proof way in line with the requirements of FDA Regulation 21 CFR 11.. version 4, GLP edition

9053-0042

Multi Management Software APT-COM™

APT-COM™ 4 GLP-Edition - for working under GLP-compliant conditions. Measured values are documented in a tamper-proof way in line with the requirements of FDA Regulation 21 CFR 11.

pH-neutral detergent

Concentrated, for gentle remove of residual contaminants; 1 kg

8012-2250

1002-0016-Neutralreiniger-100x85_Web_670x515.jpg

pH-neutral detergent - concentrated, for gentle remove of residual contaminants; 1 kg

Qualification documents

IQ/OQ documents – supporting documents for validation performed by customers, consisting of: IQ/OQ checklists incl. calibration guide and comprehensive unit documentation; parameters: temperature, CO2, O2, pressure, depending on unit. Hard copy inside folder

7007-0001

Qualification documents

IQ/OQ documents – supporting documents for validation performed by customers, consisting of: IQ/OQ checklists incl. calibration guide and comprehensive unit documentation; parameters: temperature, CO2, O2, pressure, depending on unit. Digital in PDF format

7057-0001

Qualification documents

IQ/OQ/PQ documents – supporting documents for validation performed by customers, according to customer requirements, PQ section added to qualification folder IQ/OQ; parameters: temperature, CO2, O2 – or pressure, depending on unit. Hard copy inside folder

7007-0005

Qualification documents

IQ/OQ/PQ documents – supporting documents for validation performed by customers, according to customer requirements, PQ section added to qualification folder IQ/OQ; parameters: temperature, CO2, O2 – or pressure, depending on unit. Digital in PDF format

7057-0005

Sorry, no result could be found. Check the spelling or use a new search term.

Access port with silicone plug

Top. 30 mm

8012-0045

Access port with silicone plug

Access port with silicone plug - 30 mm, top

Access port with silicone plug

Right. 30 mm

8012-0046

Access port with silicone plug

Access port with silicone plug - 30 mm, right

Access port with silicone plug

Left. 30 mm

8012-0047

Access port with silicone plug

Access port with silicone plug - 30 mm, left

Access port with silicone plug

Top. 50 mm

8012-0049

Access port with silicone plug

Access port with silicone plug - 50 mm, top

Access port with silicone plug

Right. 50 mm

8012-0050

Access port with silicone plug

Access port with silicone plug - 50 mm, right

Access port with silicone plug

Left. 50 mm

8012-0051

Access port with silicone plug

Access port with silicone plug - 50 mm, left

Access port with silicone plug

Top. 100 mm

8012-0053

Access port with silicone plug

Access port with silicone plug - 100 mm, top

Access port with silicone plug

Top. 10 mm

8012-0386

Access port with silicone plug

Access port with silicone plug - 10 mm, top

Access port with silicone plug

Right. 10 mm

8012-0387

Access port with silicone plug

Access port with silicone plug - 10 mm, right

Access port with silicone plug

Left. 10 mm

8012-0388

Access port with silicone plug

Access port with silicone plug - 10 mm, left

Access port with silicone plug

Back. 10 mm

8012-0390

Access port with silicone plug

Access port with silicone plug - 10 mm, back

Access port with silicone plug

Back. 30 mm

8012-0397

Access port with silicone plug

Access port with silicone plug - 30 mm, back

Access port with silicone plug

Back. 50 mm

8012-0399

Access port with silicone plug

Access port with silicone plug - 50 mm, back

Calibration certificate, temperature

Temperature measurement incl. certificate, 9 measuring points at specified temperature

8012-0915

Calibration certificate, temperature

Temperature measurement incl. certificate, 15- 18 measuring points at specified temperature

8012-0918

Calibration certificate, temperature

Temperature measurement incl. certificate and 27 measuring points at specified temperature

8012-0921

Calibration certificate, expanded

For temperature; for extending the measurement in center of chamber to include another test temperature

8012-1110

Calibration certificate, temperature

For temperature, measurement in center of chamber at specified temperature

8012-1129

Pt 100 temperature sensor

Additional flexible Pt 100, interior, for displaying the temperature on the unit display

8012-0940

Pt 100 temperature sensor

Pt 100 temperature sensor - additional flexible Pt 100, interior, for displaying the temperature on the unit display

Analog output 4-20 mA

For temperature values (output not adjustable)

8012-0941

Alarm function for overheating

Switchable acoustic alarm, with adjustable limit value on the independent temperature safety device

8012-0979

Clock

Battery-backed

8012-0981

Inner chamber, reinforced

Max. total load 350 kg

8012-1828

Ethernet interface

For Multi Management Software APT-COM™

8012-0987

Door lock

Lockable door handle

8012-1026

Door lock

Door lock - lockable door handle

Sorry, no result could be found. Check the spelling or use a new search term.

Temperature calibration

Extension of calibration of one (1) additional test temperature specified by the user in the center of the usable space, including certificate Travel to be quoted separate

DL30-0102

Services

Temperature calibration - Extension of calibration of one (1) additional test temperature specified by the user in the center of the usable space, including certificate Travel to be quoted separate.

Temperature measurement, 9 measuring points

Temperature measurement with 9 measuring points with a set value specified by the user, including certificate. Travel to be quoted separate.  A total of 3 shelvesare required

DL30-0109

Services

Temperature measurement, 9 measuring points - Temperature measurement with 9 measuring points with a set value specified by the user, including certificate. Travel to be quoted separate.  A total of 3 shelvesare required.

Temperature measurement, 18 measuring points

Temperature measurement with 18 measuring points with a set value specified by the user, including certificate. Travel to be quoted separate.  A total of 2 shelvesare required

DL30-0118

Services

Temperature measurement, 18 measuring points - Temperature measurement with 18 measuring points with a set value specified by the user, including certificate. Travel to be quoted separate.  A total of 2 shelvesare required.

Temperature measurement, 27 measuring points

Temperature measurement with 27 measuring points with a set value specified by the user, including certificate. Travel to be quoted separate.  A total of 3 shelvesare required

DL30-0127

Services

Temperature measurement, 27 measuring points - Temperature measurement with 27 measuring points with a set value specified by the user, including certificate. Travel to be quoted separate.  A total of 3 shelvesare required.

Execution of IQ/OQ/PQ

Execution of IQ/OQ/PQ in accordance with qualification folder. Travel to be quoted separate

DL44-0500

Services

Execution of IQ/OQ/PQ - Execution of IQ/OQ/PQ in accordance with qualification folder. Travel to be quoted separate.

BRONZE 3-year maintenance contract

Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate. 10% Discount on Spare Parts and Labor for any additional Services needed Wear + tear parts to be purchased or billed to customer. Travel to be quoted as separate

DL20-0720

Services

BRONZE 3-year maintenance contract - Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate. 10% Discount on Spare Parts and Labor for any additional Services needed Wear + tear parts to be purchased or billed to customer. Travel to be quoted as separate.

SILVER 3-year maintenance contract

Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate 15% Discount on Spare Parts and Labor for any additional Services needed One additional courtesy visit per year can be used for service visit or operator training. Wear + tear parts to be purchased or billed to customer. Travel to be quoted separate

DL20-0815

Services

SILVER 3-year maintenance contract - Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate 15% Discount on Spare Parts and Labor for any additional Services needed One additional courtesy visit per year can be used for service visit or operator training. Wear + tear parts to be purchased or billed to customer. Travel to be quoted separate.

GOLD 3-year maintenance contract

Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate of Temperature. 25% Discount on Spare Parts and Labor for any additional Services needed. One additional courtesy visit per year can be used for service visit or operator. Wear + tear parts to be purchased or billed to customer. Travel to be quoted separate

DL20-0915

Services

GOLD 3-year maintenance contract - Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate of Temperature. 25% Discount on Spare Parts and Labor for any additional Services needed. One additional courtesy visit per year can be used for service visit or operator. Wear + tear parts to be purchased or billed to customer. Travel to be quoted separate.

Unit installation

Connect the unit to the customer-side connections (electricity, water, wastewater, gas), basic functions check, brief operating instructions. (excl.: unpacking, setup, controller instructions, programming, installation work) Travel to be quoted as separate

DL10-0100

Services

Unit installation - Connect the unit to the customer-side connections (electricity, water, wastewater, gas), basic functions check, brief operating instructions. (excl.: unpacking, setup, controller instructions, programming, installation work) Travel to be quoted as separate.

Unit instructions

Instruction regarding operating principle and basic functions of the unit, operation of the control electronics including programming. Travel to be quoted as separate Limited to 3 hours

DL10-0500

Services

Unit instructions - Instruction regarding operating principle and basic functions of the unit, operation of the control electronics including programming. Travel to be quoted as separate Limited to 3 hours.

Preventive maintenance 

One-off maintenance service in accordance with maintenance schedule. Visual inspection of mechanical and electrical components, testing of all key functions. Checking a test temperature specified by the user in center of usable space without certificate. Wear + tear parts need to be purchased or billed to customer. Travel to be quoted as separate

DL20-0601

Services

Preventive maintenance  - One-off maintenance service in accordance with maintenance schedule. Visual inspection of mechanical and electrical components, testing of all key functions. Checking a test temperature specified by the user in center of usable space without certificate. Wear + tear parts need to be purchased or billed to customer. Travel to be quoted as separate.

Temperature calibration

Calibration of one (1) test temperature specified by the user in center of chamber, including certificate Travel to be quoted separate

DL30-0110

Services

Temperature calibration - Calibration of one (1) test temperature specified by the user in center of chamber, including certificate Travel to be quoted separate.

1-year warranty extension

The warranty is extended by 1 year from the delivery date, wear parts are excluded

DL50-0010

Services

1-year warranty extension - The warranty is extended by 1 year from the delivery date, wear parts are excluded

Execution of IQ/OQ

Execution of IQ/OQ in accordance with qualification folder. Travel to be quoted separate

DL40-0100

Services

Execution of IQ/OQ - Execution of IQ/OQ in accordance with qualification folder. Travel to be quoted separate.

Suggested products

Compare products:

Or add another product.