Series MKF | Dynamic climate chambers for rapid temperature changes with humidity control

A BINDER MKF series environmental simulation chamber is ideally suited for any cold and heat testing based on current temperature and climate testing methods according to DIN and IEC standards. The comprehensive standard equipment for this environmental simulation chamber ensures ease of operation.

Benefits

  • Homogeneous climate conditions thanks to APT.line™ technology
  • Automatic water and wastewater management
  • Pressure humidification with fast response times
  • Comprehensive programming and data acquisition
  • Large heated viewing window

Important characteristics

  • Temperature range: -40 °C to 180 °C
  • Humidity range: 10 % to 98 % RH
  • Integrated water-storage tank, 20 liters (Models 115, 240, 720)
  • 4 zero-voltage relay contacts
  • 1 stainless steel rack
  • APT.line™ preheating chamber technology
  • Intuitive touchscreen controller with time-segment and real-time programming
  • Internal data logger, measured values can be read out in open format via USB
  • Programmable condensation protection for test material
  • Heated viewing window with LED interior lighting
  • Humidity regulation with capacitative humidity sensor and vapor humidification
  • BINDER Multi Management Software APT-COM™ Basic Edition
  • Troubleshooting system with visual and audible alarms
  • Access port with silicone plug (Models 56, 115, 240: 50 mm, left)
  • 2 access ports with silicone plugs (Model 720: 80 mm, left and right)
  • Class 2 independent adjustable temperature safety device (DIN 12880) with visual alarm
  • 4 castors, two with brakes
  • Computer interface: Ethernet
  • 230 V power socket on the right-side control panel (Models 115, 240, 720)
  • Adjustable ramp function
  • Integrated chart recorder
  • Real-time clock
  • Door heating
  • Alarm notification in the event of insufficient water in fresh water tank (Models 115, 240, 720)
  • Complete safety connection kit for water supply and drainage, up to 1 m height
  • Inner chamber made of stainless steel
  • CFC-free refrigerant R-404A
  • Cooling with compressor cooling unit
Models
  • Model MKF 56
  • Housing dimensions not incl. fittings and connections - W x H x D [in]: 28.37 x 56.9 x 30.73
  • Internal dimension W x H x D [in]: 15.76 x 16.55 x 13.71
  • Net weight [lbs]: 386
  • Interior volume [cu.ft.]: 2.1
  • Bookmark +
  • Model MKF 115
  • Housing dimensions not incl. fittings and connections - W x H x D [in]: 38.61 x 68 x 34.08
  • Internal dimension W x H x D [in]: 23.64 x 18.91 x 15.76
  • Net weight [lbs]: 617
  • Interior volume [cu.ft.]: 4.1
  • Bookmark +
  • Model MKF 240
  • Housing dimensions not incl. fittings and connections - W x H x D [in]: 43.9 x 67.6 x 36.45
  • Internal dimension W x H x D [in]: 28.96 x 27.58 x 17.45
  • Net weight [lbs]: 794
  • Interior volume [cu.ft.]: 8
  • Bookmark +
  • Model MKF 720
  • Housing dimensions not incl. fittings and connections - W x H x D [in]: 62.3 x 79 x 44.9
  • Internal dimension W x H x D [in]: 47.3 x 40.2 x 23.64
  • Net weight [lbs]: 1900
  • Interior volume [cu.ft.]: 25.9
  • Bookmark +
Technical data

Please select a model to view technical data:

Services
MSRP* [?] Merken
  • Designation:

    Execution of IQ/OQ

  • Description:

    Execution of IQ/OQ in accordance with qualification folder

  • Art. No.: DL42-0300
- +
  • Designation:

    Execution of IQ/OQ/PQ

  • Description:

    Execution of IQ/OQ/PQ in accordance with qualification folder

  • Art. No.: DL44-0500
- +
  • Designation:

    Leakage test

  • Description:

    Maintenance service in accordance with maintenance schedule. Visual inspection of mechanical and electrical components, testing of all key functions. Calibration of a test temperature specified by the user in center of chamber without certificate

  • Art. No.: DL00-0034
- +
  • Designation:

    Maintenance

  • Description:

    Maintenance service in accordance with maintenance schedule. Visual inspection of mechanical and electrical components, testing of all key functions. Calibration of a test temperature specified by the user in center of chamber without certificate

  • Art. No.: DL20-0500
- +
  • Designation:

    Temperature and humidity calibration

  • Description:

    Temperature and humidity calibration with 1 measuring point in center of chamber with 1 specified pair of values, including certificate

  • Art. No.: DL30-0301
- +
  • Designation:

    Temperature and humidity calibration

  • Description:

    Expansion –Temperature and humidity calibration with 1 measuring point in center of chamber with 1 specified pair of values, including certificate

  • Art. No.: DL30-0302
- +
  • Designation:

    Temperature and humidity measurement according to DIN12880

  • Description:

    Temperature measurement in accordance with DIN 12880 with 27 temperature measuring points and 1 humidity measuring point in center of chamber with a pair of values specified by the user, including certificate

  • Art. No.: DL30-0427
- +
  • Designation:

    Temperature measurement, 18 temperature measuring points and 1 humidity measuring point

  • Description:

    Temperature measurement with 18 temperature measuring points and 1 humidity measuring point in center of chamber with a pair of values specified by the user, including certificate

  • Art. No.: DL30-0318
- +
  • Designation:

    Temperature measurement, 27 temperature measuring points and 1 humidity measuring point

  • Description:

    Temperature measurement with 27 temperature measuring points and 1 humidity measuring point in center of chamber with a pair of values specified by the user, including certificate

  • Art. No.: DL30-0327
- +
  • Designation:

    Temperature measurement, 9 temperature measuring points and 1 humidity measuring point

  • Description:

    Temperature measurement with 9 temperature measuring points and 1 humidity measuring point in center of chamber with a pair of values specified by the user, including certificate

  • Art. No.: DL30-0309
- +
  • Designation:

    Unit installation

  • Description:

    Connect the unit to the customer-side connections (electricity, water, wastewater, gas), basic functions check, brief operating instructions. (excl.: unpacking, setup, controller instructions, programming, installation work)

  • Art. No.: DL10-0300
- +
  • Designation:

    Unit instructions

  • Description:

    Instruction regarding operating principle and basic functions of the unit, operation of the control electronics including programming

  • Art. No.: DL10-0700
- +
  • Designation:

    Warranty extension from 2 to 3 years

  • Description:

    The warranty is extended from 2 to 3 years from the delivery date, wear parts are excluded

  • Art. No.: DL01-3041
- +
  • Designation:

    Warranty extension from 2 to 5 years

  • Description:

    The warranty is extended from 2 to 5 years from the delivery date, wear parts are excluded

  • Art. No.: DL01-3042
- +
Options and Accessories

Complementary to our products we offer a broad range of options and accessories - from access ports and to racks to documentation and software.

Please select a model to get an overview of all available options and accessories for this product:

Downloads

MKF | MKFT series

  • Category: Operating Manuals
  • File type / size PDF (12.54 MB)

Dynamic climate chamber (MKF series) - An endurance test for the car Lothar Bix GmbH

  • Category: Case Studies
  • File type / size PDF (921.55 kB)

Dynamic climate chambers (MKF series) - Energy storage devices undergo endurance testing TÜV SÜD Battery Testing GmbH

  • Category: Case Studies
  • File type / size PDF (1.72 MB)

Trends in consumer behavior How has the food industry changed in industrialized countries?

  • Category: White paper
  • File type / size PDF (157.03 kB)

Artificial aging Predicting material behavior

  • Category: White paper
  • File type / size PDF (435.64 kB)

Validation and Qualification In the regulated environment

  • Category: White paper
  • File type / size PDF (393.27 kB)

Data Logger Kits – temperature and humidity Data Logger Kit NET 100 | Data Logger Kit NET 100/60

  • Category: Options & Accessories
  • File type / size PDF (256.74 kB)

PURE AQUA SERVICE Serie KBF| KBF P | KBF LQC | KMF | KBWF | MKF | MKFT

  • Category: Options & Accessories
  • File type / size PDF (335.95 kB)

Battery test chambers with package A and package P for testing lithium-ion energy storage devices PACKAGE A | PACKAGE P

  • Category: Brochures
  • File type / size PDF (256.93 kB)

Dynamic climate chambers MK | MKF | MKT | MKFT series

  • Category: Brochures
  • File type / size PDF (2.30 MB)

BINDER Service 100 % performance and availability

  • Category: Brochures
  • File type / size PDF (1.12 MB)

BINDER INDIVIDUAL Series production devices for special requirements

  • Category: Brochures
  • File type / size PDF (713.75 kB)

Environmental simulation chambers for rapid temperature changes with humidity control

BINDER environmental simulation chambers in the MKF series are ideally suited for all testing based on current temperature and climate testing standards. These dynamic climate chambers operate within a temperature range of between -40 °C and 180 °C, and a humidity range of between 10% RH and 98% RH. Homogeneous temperature distribution is guaranteed across the entire usable space thanks to the patented APT.line™ preheating chamber technology. Even when chambers are fully loaded, you can rely on the temperature conditions being homogeneous, thereby ensuring identical test conditions.
BINDER MKF series environmental simulation chambers are the number one choice for dynamic climate profiles. The required temperatures and humidity values can be reached quickly and accurately maintained during the test phase, with precise measurement results guaranteed.

BINDER environmental simulation chambers with extensive equipment

The equipment features of the MKF environmental simulation chambers from BINDER include a built-in water tank, programmable condensation protection for samples, and a heated viewing window with LED interior lighting. Humidity is regulated using a capacitive humidity sensor and steam humidification. The dynamic climate chambers are really easy to use thanks to the controller with interval programming, while the troubleshooting system with visual and acoustic alarms takes care of safety. As the interior is fully coated with stainless steel, the environmental simulation chambers can be cleaned without any hassle, reducing the risk of contamination to a minimum. The climate chambers have four casters, making them really flexible, and with two casters with locking brakes, stability and secure positioning are no problem at the use location.
BINDER environmental simulation chambers in the MKF series are the number one choice for rapid temperature changes and humidity control. Impressing with their performance, precision, and safety, these units also boast ease of use and a broad, flexible scope of application.