Important characteristics
Details of the model
Select version
MSRP* [?] | Merken | |
---|---|---|
Model FED 56 | ||
|
- | + |
|
- | + |
Technical data
The PDF data sheet contains technical data, options & accessories as well as services.
Downloads
Serie CKurzanleitung
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
Rated voltage | Option model | Version | Art. No. | MSRP* [?] | Selection | Bookmark |
---|---|---|---|---|---|---|
Model FED 56 | ||||||
230 V 1~ 50/60 Hz | ||||||
Standard |
FED056-230V¹ | 9010-0295 | - | + | ||
120 V 1~ 60 Hz | ||||||
Standard |
FED056UL-120V¹ | 9010-0296 | - | + |
Designation | Description | Art. No. | MSRP* [?] | Bookmark | ||
---|---|---|---|---|---|---|
Access port with silicone plug | ||||||
top |
8012-1264 | - | + | |||
top |
8012-1672 | - | + | |||
left |
8012-1657 | - | + | |||
right |
8012-1656 | - | + | |||
left |
8012-1655 | - | + | |||
right |
8012-1654 | - | + | |||
top |
8012-1381 | - | + | |||
top |
8012-1365 | - | + | |||
left |
8012-1278 | - | + | |||
right |
8012-1271 | - | + | |||
Analog output 4-20 mA | ||||||
for temperature values (output not adjustable) |
8012-1625 | - | + | |||
Calibration certificate, expanded | ||||||
for temperature; for extending the measurement in center of chamber to include another test temperature |
8012-1118 | - | + | |||
Calibration certificate, temperature | ||||||
temperature measurement incl. certificate and 27 measuring points at specified temperature |
8012-1596 | - | + | |||
temperature measurement incl. certificate, 15- 18 measuring points at specified temperature |
8012-1575 | - | + | |||
temperature measurement incl. certificate, 9 measuring points at specified temperature |
8012-1554 | - | + | |||
for temperature, measurement in center of chamber at specified temperature |
8012-1137 | - | + | |||
Cart | ||||||
Cart – stable cart, casters with locking brakes, dimensions: W 1,000 x D 800 x H 780 mm |
9051-0018 | - | + | |||
Class 3.1 independent temperature safety device | ||||||
with visual alarm (DIN 12880) |
8012-1644 | - | + | |||
Clock | ||||||
battery-backed |
8012-1642 | - | + | |||
Data Logger Kit | ||||||
T 350: For continuous temperature logging from 0 °C to 350 °C; kit includes 1 data logger, Pt 100 sensor with 2 m extension cable and 1 magnetic fixture for mounting to the BINDER unit |
8012-0714 | - | + | |||
Data Logger Software | ||||||
LOG ANALYZE software kit, configuration and evaluation software for all BINDER Data Logger Kits (incl. USB data cable) |
8012-0821 | - | + | |||
Door gasket | ||||||
made of FKM, silicone-free |
8012-1649 | - | + | |||
Door lock | ||||||
lockable door handle |
8012-1666 | - | + | |||
Gas-tight option model | ||||||
Incl. additional measures for the greatest possible impermeability to gas; not in conjunction with access port or interior lighting option |
8012-1684 | - | + | |||
Heating output, reinforced | ||||||
For faster heating up time and improved recovery time; max. 300 °C; not in conjunction with load management option |
8012-1698 | - | + | |||
HEPA air filter | ||||||
On fresh air supply for unit; filter classification H14 (acc. to. EN 1822-1:2009, > 99.995% at 0.3 µm) |
8012-1695 | - | + | |||
Inert gas connection | ||||||
With gas inlet and outlet, Ø 10 mm, incl. additional measures for the greatest possible impermeability to gas; not in conjunction with access port or interior lighting option |
8012-1690 | - | + | |||
Inner chamber, reinforced | ||||||
max. total load 85 kg |
8012-1713 | - | + | |||
Instrument tray | ||||||
with lid made from 18/8 stainless steel, stackable, dimensions: 315 x 215 x 60 mm |
4022-0124 | - | + | |||
with lid made from 18/8 stainless steel, stackable, dimensions: 230 x 133 x 45 mm |
4022-0123 | - | + | |||
Interior lighting | ||||||
with 15 W light bulb |
8012-1633 | - | + | |||
with 15 W light bulb |
8012-1629 | - | + | |||
Measurement of air exchange rate | ||||||
in accordance with ASTM D5374, definition and protocol according to ambient temperature |
8012-1197 | - | + | |||
Overheating alarm | ||||||
audible, can be switched off, adjustable limit on the independent temperature safety device |
8012-1637 | - | + | |||
pH-neutral detergent | ||||||
concentrated, for gentle remove of residual contaminants; 1 kg |
1002-0016 | - | + | |||
Pt 100 temperature sensor | ||||||
additional flexible Pt 100, interior, for displaying the temperature on the unit display |
8012-1621 | - | + | |||
Rack, heavy load | ||||||
Stainless steel, max. load per rack 50 kg |
6004-0198 | - | + | |||
Racks | ||||||
stainless steel |
6004-0150 | - | + | |||
chrome-plated |
6004-0166 | - | + | |||
Rubber pads | ||||||
set of 4 anti-slip feet, for safe stacking of unit |
8012-0001 | - | + | |||
Shelf, perforated | ||||||
|
6004-0182 | - | + | |||
Software | ||||||
APT-COM™ communications software |
9053-0016 | - | + | |||
APT-COM™ communications software |
9053-0015 | - | + | |||
APT-COM™ communications software |
9053-0014 | - | + | |||
APT-COM™ communications software |
9053-0013 | - | + | |||
APT-COM™ communications software, price: for free |
9053-0008 | - | + | |||
Viewing window and interior lighting | ||||||
viewing window (triple insulating glass) in door, 240 x 240 mm, and 15 W interior |
8012-1703 | - | + | |||
viewing window (triple insulating glass) in door, 240 x 240 mm, and 15 W interior |
8012-1701 | - | + |
Designation | Description | Art. No. | MSRP* [?] | Bookmark | ||
---|---|---|---|---|---|---|
Calibration temperature incl. certificate |
including certificate, one measuring point in center of chamber at specified temperature |
DL30-0101 | - | + | ||
Execution of IQ/OQ |
in accordance with qualification folder |
DL40-0100 | - | + | ||
Execution of IQ/OQ/PQ |
in accordance with customer's requirement, price: on request |
DL44-0500 | - | + | ||
Extension of the warranty from 2 to 3 years |
beginning with the date of delivery, wearing parts are not included |
DL00-4041 | - | + | ||
Extension of the warranty from 2 to 5 years |
beginning with the date of delivery, wearing parts are not included |
DL00-4042 | - | + | ||
Installation |
and set up of unit at operating location, connect to existing connections |
DL10-0100 | - | + | ||
Instruction |
unit function instructions for operation and programming of the controller |
DL10-0400 | - | + | ||
Measurement of air exchange rate |
including certificate (in accordance with ASTM D5374) |
DL33-0000 | - | + | ||
Preventive maintenance |
Executive of equipment inspection according to maintenance plan |
DL20-0200 | - | + | ||
Qualification folder IQ/OQ |
supporting documents for validation performed by customer, consisting of: IQ/OQ checklists, unit schematics, QM certificate in accordance with ISO 9001 |
8012-0855 | - | + | ||
Qualification folder IQ/OQ/PQ |
supporting documents for validation performed by customer, in accordance with customer's requirement, extension of Qualification folder IQ/OQ by chapter PQ |
8012-0944 | - | + | ||
Temperature measurement 18 measuring points |
including certificate, 18 measuring points at specified temperature |
DL30-0118 | - | + | ||
Temperature measurement 27 measuring points |
including certificate, 27 measuring points at specified temperature |
DL30-0127 | - | + | ||
Temperature measurement 9 measuring points |
including certificate, 9 measuring points at specified temperature |
DL30-0109 | - | + |
Designation | FED056UL-120V¹ | FED056-230V¹ |
---|---|---|
Option model | Standard | Standard |
Order number | 9010-0296 | 9010-0295 |
Measures | ||
Interior volume [L] | 60 | 60 |
Net weight of the unit (empty) [kg] | 39 | 39 |
permitted load [kg] | 70 | 70 |
Load per rack [kg] | 30 | 30 |
Doors | ||
Unit doors | 1 | 1 |
Internal Dimensions | ||
Width [mm] | 400 | 400 |
Height [mm] | 440 | 440 |
Depth [mm] | 345 | 345 |
Outer dimensions | ||
Width net [mm] | 560 | 560 |
Height net [mm] | 625 | 625 |
Depth net [mm] | 565 | 565 |
Wall clearance back [mm] | 160 | 160 |
Wall clearance sidewise [mm] | 100 | 100 |
Environment-specific data | ||
Energy consumption at 150 °C [Wh/h] | 290 | 290 |
Sound-pressure level [dB(A)] | 43 | 43 |
Fixtures | ||
Number of shelves (std./max.) | 2/4 | 2/4 |
Performance Data Temperature | ||
Temperature range 10 °C above ambient temperature to [°C] | 300 | 300 |
Temperature variation at 150 °C [± K] | 1.4 | 1.4 |
Temperature fluctuation at 150 °C [± K] | 0.3 | 0.3 |
Heating-up time to 150 °C [min] | 15 | 15 |
Recovery time after 30 seconds door open at 150 °C [min] | 4 | 4 |
Electrical data | ||
Rated Voltage [V] | 120 | 230 |
Power frequency [Hz] | 60 | 50/60 |
Nominal power [kW] | 1.2 | 1.1 |
Unit fuse [A] | 12.5 | 6.3 |
Phase (Nominal voltage) | 1~ | 1~ |
Measures | ||
Interior volume [cu.ft.] | 2.1 | 2.1 |
Net weight of the unit (empty) [lbs] | 86 | 86 |
permitted load [lbs] | 154 | 154 |
Load per rack [lbs] | 66 | 66 |
Doors | ||
Unit doors | 1 | 1 |
Internal Dimensions | ||
Width [in] | 15.76 | 15.76 |
Height [in] | 17.34 | 17.34 |
Depth [in] | 13.59 | 13.59 |
Outer dimensions | ||
Width net [in] | 22.06 | 22.06 |
Height net [in] | 24.63 | 24.63 |
Depth net [in] | 22.26 | 22.26 |
Wall clearance back [in] | 6.3 | 6.3 |
Wall clearance sidewise [in] | 3.94 | 3.94 |
Environment-specific data | ||
Energy consumption at 150 °C [Wh/h] | 290 | 290 |
Sound-pressure level [dB(A)] | 43 | 43 |
Fixtures | ||
Number of shelves (std./max.) | 2/4 | 2/4 |
Performance Data Temperature | ||
Temperature range 10 °C above ambient temperature to [°C] | 300 | 300 |
Temperature variation at 150 °C [± K] | 1.4 | 1.4 |
Temperature fluctuation at 150 °C [± K] | 0.3 | 0.3 |
Heating-up time to 150 °C [min] | 15 | 15 |
Recovery time after 30 seconds door open at 150 °C [min] | 4 | 4 |
Electrical data | ||
Rated Voltage [V] | 120 | 230 |
Power frequency [Hz] | 60 | 50/60 |
Nominal power [kW] | 1.2 | 1.1 |
Unit fuse [A] | 12.5 | 6.3 |
Phase (Nominal voltage) | 1~ | 1~ |
Category | Title | File type / size | Download |
---|---|---|---|
Data Sheets |
FED 56 |
PDF (161.21 kB ) | > |
FED 56 US version with imperial values |
PDF (161.37 kB) | > | |
Operating Manuals |
BD | BF | ED | FD | FED series Avantgarde.Line Models 56 | 115 | 260 | 720 |
PDF (10.62 MB) | > |
Operating Manuals |
FED series |
PDF (3.53 MB) | > |
Operating Manuals |
Quick Start Guide BD | BF | ED | FD | FED series |
PDF (2.54 MB) | > |
Technical Drawings |
Model FED 56 Interior dimensions |
PDF (181.60 kB) | > |
Technical Drawings |
Model FED 56 External dimensions |
PDF (189.51 kB) | > |
Technical Drawings |
Model FED 56 Access ports |
PDF (99.91 kB) | > |
Technical Drawings |
Model FED 56 Access ports BINDER INDIVIDUAL |
PDF (92.81 kB) | > |
Case Studies |
Drying and heating chambers (Series ED | FED) - Carbon frames for racing bikes Swiss Manufacturing Technology AG |
PDF (2.91 MB) | > |
Case Studies |
Drying and heating chambers (Series ED | FED) | Vacuum drying chambers (Serie VD) - Cable testing DNV KEMA Energy & Sustainability, KEMA Nederland B.V. |
PDF (537.65 kB) | > |
Case Studies |
Drying and heating chambers (Series FED) - Visual systems Orlaco Products B.V. |
PDF (1.08 MB) | > |
Case Studies |
Drying and heating chambers (Series ED | FED) - Carbon frames for racing bikes SWT Swiss Manufacturing Technology AG, BMC Swiss Cycling Technologie |
PDF (1.90 MB) | > |
Brochures |
Drying and heating chambers E | ED | FD | FED | FP | M series |
PDF (2.40 MB) | > |
White paper |
Artificial aging Predicting material behavior |
PDF (435.64 kB) | > |