Important characteristics
Details of the model
Select version
MSRP* [?] | Merken | |
---|---|---|
Model C 170 | ||
|
- | + |
|
- | + |
|
- | + |
|
- | + |
Technical data
The PDF data sheet contains technical data, options & accessories as well as services.
Downloads
Serie CKurzanleitung
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
Rated voltage | Option model | Version | Art. No. | MSRP* [?] | Selection | Bookmark |
---|---|---|---|---|---|---|
Model C 170 | ||||||
120 V 1~ 60 Hz | ||||||
Door hinged right |
C170UL-120V-R¹ | 9040-0113 | - | + | ||
Door hinged left |
C170UL-120V-L¹ | 9040-0116 | - | + | ||
230 V 1~ 50/60 Hz | ||||||
Door hinged right |
C170-230V-R¹ | 9040-0112 | - | + | ||
Door hinged left |
C170-230V-L¹ | 9040-0115 | - | + |
Designation | Description | Art. No. | MSRP* [?] | Bookmark | ||
---|---|---|---|---|---|---|
Access port with silicone plug | ||||||
back |
8012-0558 | - | + | |||
left |
8012-0559 | - | + | |||
right |
8012-0560 | - | + | |||
Analog output 4-20 mA | ||||||
for temperature and CO₂ values (outputs not adjustable) |
8012-0742 | - | + | |||
Base | ||||||
with casters |
9051-0029 | - | + | |||
Calibration certificate, expanded | ||||||
for temperature; for extending the measurement in center of chamber to include another test temperature |
8012-1112 | - | + | |||
Calibration certificate, temperature | ||||||
for temperature, measurement in center of chamber at specified temperature |
8012-1131 | - | + | |||
temperature measurement incl. certificate, 9 measuring points at specified temperature |
8012-1549 | - | + | |||
temperature measurement incl. certificate, 15- 18 measuring points at specified temperature |
8012-1570 | - | + | |||
temperature measurement incl. certificate and 27 measuring points at specified temperature |
8012-1591 | - | + | |||
Calibration certificate, temperature and CO₂ | ||||||
for temperature and CO₂, temperature measurement in center of chamber, CO₂ measurement performed using test gas at 37 °C and 5 % CO₂ |
8012-0228 | - | + | |||
Cleaning kit | ||||||
for equipment maintenance and disinfection, consisting of pH-neutral detergent (1000 g, concentrate), spray disinfectant (500 ml, ready-to-use solution), lint-free cleansing tissues, protective gloves, and protective glasses |
8012-0503 | - | + | |||
Copper interior fittings | ||||||
Set consisting of 3 shelves (all-copper) and a water pan (copper-plated), more information. |
8012-1765 | - | + | |||
Door lock | ||||||
lockable door handle |
8012-1014 | - | + | |||
Ethernet interface | ||||||
for communication software |
8012-0604 | - | + | |||
Gas cylinder connection set | ||||||
for CO₂, consisting of a gas tank pressure regulator with connection parts and 5-meter hose |
8012-0014 | - | + | |||
Gas tank changer | ||||||
external, BINDER Gas Supply Service, for connecting 2 gas tanks (CO₂, N₂ or O₂), with audible and visual alarms, as well as zero-voltage alarm output |
8012-0408 | - | + | |||
pH-neutral detergent | ||||||
concentrated, for gentle remove of residual contaminants; 1 kg |
1002-0016 | - | + | |||
Rubber pads | ||||||
set of 4 anti-slip feet, for safe stacking of unit |
8012-0001 | - | + | |||
Shelf, perforated | ||||||
|
6004-0142 | - | + | |||
Stacking adapter, flat | ||||||
for thermally decoupled stacking of two identical units |
9051-0036 | - | + |
Designation | Description | Art. No. | MSRP* [?] | Bookmark | ||
---|---|---|---|---|---|---|
Calibration CO₂ |
including certificate, CO₂ measurement with analyzed test gas at 5 % or at specified value |
DL30-0401 | - | + | ||
Calibration temperature incl. certificate |
including certificate, one measuring point in center of chamber at specified temperature |
DL30-0101 | - | + | ||
Execution of IQ/OQ |
in accordance with qualification folder |
DL41-0200 | - | + | ||
Execution of IQ/OQ/PQ |
in accordance with customer's requirement, price: on request |
DL44-0500 | - | + | ||
Extension of the warranty from 2 to 3 years |
beginning with the date of delivery, wearing parts are not included |
DL02-0041 | - | + | ||
Extension of the warranty from 2 to 5 years |
beginning with the date of delivery, wearing parts are not included |
DL02-0042 | - | + | ||
Installation |
and set up of unit at operating location, connect to existing connections |
DL10-0200 | - | + | ||
Instruction |
unit function instructions for operation and programming of the controller |
DL10-0500 | - | + | ||
Preventive maintenance |
Executive of equipment inspection according to maintenance plan |
DL20-0400 | - | + | ||
Qualification folder IQ/OQ |
supporting documents for validation performed by customer, consisting of: IQ/OQ checklists, unit schematics, QM certificate in accordance with ISO 9001 |
8012-0875 | - | + | ||
Qualification folder IQ/OQ/PQ |
supporting documents for validation performed by customer, in accordance with customer's requirement, extension of Qualification folder IQ/OQ by chapter PQ |
8012-0962 | - | + | ||
Temperature measurement 18 measuring points |
including certificate, 18 measuring points at specified temperature |
DL30-0118 | - | + | ||
Temperature measurement 27 measuring points |
including certificate, 27 measuring points at specified temperature |
DL30-0127 | - | + | ||
Temperature measurement 9 measuring points |
including certificate, 9 measuring points at specified temperature |
DL30-0109 | - | + |
Designation | C170UL-120V-R¹ | C170UL-120V-L¹ | C170-230V-R¹ | C170-230V-L¹ |
---|---|---|---|---|
Option model | Door hinged right | Door hinged left | Door hinged right | Door hinged left |
Order number | 9040-0113 | 9040-0116 | 9040-0112 | 9040-0115 |
Measures | ||||
Interior volume [L] | 168 | 168 | 168 | 168 |
Net weight of the unit (empty) [kg] | 96 | 96 | 96 | 96 |
Load per rack [kg] | 10 | 10 | 10 | 10 |
Doors | ||||
Inner doors | 1 | 1 | 1 | 1 |
Unit doors | 1 | 1 | 1 | 1 |
Internal Dimensions | ||||
Width [mm] | 560 | 560 | 560 | 560 |
Height [mm] | 600 | 600 | 600 | 600 |
Depth [mm] | 500 | 500 | 500 | 500 |
Outer dimensions | ||||
Width net [mm] | 740 | 740 | 740 | 740 |
Height net [mm] | 870 | 870 | 870 | 870 |
Depth net [mm] | 715 | 715 | 715 | 715 |
Wall clearance sidewise [mm] | 50 | 50 | 50 | 50 |
Wall clearance back [mm] | 100 | 100 | 100 | 100 |
Environment-specific data | ||||
Energy consumption at 37 °C [Wh/h] | 90 | 90 | 90 | 90 |
Fixtures | ||||
Number of shelves (std./max.) | 3/8 | 3/8 | 3/8 | 3/8 |
Performance Data Temperature | ||||
Temperature range 7 °C above ambient temperature to [°C] | 50 | 50 | 50 | 50 |
Temperature variation at 37 °C [± K] | 0.3 | 0.3 | 0.3 | 0.3 |
Temperature fluctuation [± K] | 0.1 | 0.1 | 0.1 | 0.1 |
Recovery time after 30 seconds door open at 37 °C [min] | 6 | 6 | 6 | 6 |
Performance Data Climate | ||||
Humidity range [% RH] | 90…95 | 90…95 | 90…95 | 90…95 |
CO₂-Data | ||||
CO₂ range [Vol.-% CO₂] | 0…20 | 0…20 | 0…20 | 0…20 |
CO₂ measurement | IR | IR | IR | IR |
CO₂ Recovery time after 30 seconds door open at 5 Vol.-% CO₂ [min] | 7 | 7 | 7 | 7 |
Electrical data | ||||
Rated Voltage [V] | 120 | 120 | 230 | 230 |
Power frequency [Hz] | 60 | 60 | 50/60 | 50/60 |
Nominal power [kW] | 1.1 | 1.1 | 1.1 | 1.1 |
Unit fuse [A] | 10 | 10 | 10 | 10 |
Phase (Nominal voltage) | 1~ | 1~ | 1~ | 1~ |
Measures | ||||
Interior volume [cu.ft.] | 5.9 | 5.9 | 5.9 | 5.9 |
Net weight of the unit (empty) [lbs] | 212 | 212 | 212 | 212 |
Load per rack [lbs] | 22 | 22 | 22 | 22 |
Doors | ||||
Inner doors | 1 | 1 | 1 | 1 |
Unit doors | 1 | 1 | 1 | 1 |
Internal Dimensions | ||||
Width [in] | 22.06 | 22.06 | 22.06 | 22.06 |
Height [in] | 23.64 | 23.64 | 23.64 | 23.64 |
Depth [in] | 19.7 | 19.7 | 19.7 | 19.7 |
Outer dimensions | ||||
Width net [in] | 29.16 | 29.16 | 29.16 | 29.16 |
Height net [in] | 34.28 | 34.28 | 34.28 | 34.28 |
Depth net [in] | 28.17 | 28.17 | 28.17 | 28.17 |
Wall clearance back [in] | 3.94 | 3.94 | 3.94 | 3.94 |
Wall clearance sidewise [in] | 1.97 | 1.97 | 1.97 | 1.97 |
Environment-specific data | ||||
Energy consumption at 37 °C [Wh/h] | 90 | 90 | 90 | 90 |
Fixtures | ||||
Number of shelves (std./max.) | 3/8 | 3/8 | 3/8 | 3/8 |
Performance Data Temperature | ||||
Temperature range 7 °C above ambient temperature to [°C] | 50 | 50 | 50 | 50 |
Temperature variation at 37 °C [± K] | 0.3 | 0.3 | 0.3 | 0.3 |
Temperature fluctuation [± K] | 0.1 | 0.1 | 0.1 | 0.1 |
Recovery time after 30 seconds door open at 37 °C [min] | 6 | 6 | 6 | 6 |
Performance Data Climate | ||||
Humidity range [% RH] | 90…95 | 90…95 | 90…95 | 90…95 |
CO₂-Data | ||||
CO₂ range [Vol.-% CO₂] | 0…20 | 0…20 | 0…20 | 0…20 |
CO₂ measurement | IR | IR | IR | IR |
CO₂ Recovery time after 30 seconds door open at 5 Vol.-% CO₂ [min] | 7 | 7 | 7 | 7 |
Electrical data | ||||
Rated Voltage [V] | 120 | 120 | 230 | 230 |
Power frequency [Hz] | 60 | 60 | 50/60 | 50/60 |
Nominal power [kW] | 1.1 | 1.1 | 1.1 | 1.1 |
Unit fuse [A] | 10 | 10 | 10 | 10 |
Phase (Nominal voltage) | 1~ | 1~ | 1~ | 1~ |
Category | Title | File type / size | Download |
---|---|---|---|
Data Sheets |
C 170 |
PDF (138.52 kB ) | > |
C 170 US version with imperial values |
PDF (138.70 kB) | > | |
Operating Manuals |
C 170 |
PDF (4.70 MB) | > |
Technical Drawings |
Model C 170 External dimensions |
PDF (257.75 kB) | > |
Case Studies |
CO₂ incubator (Series CB) - Stem cell research into healing musculoskeletal disorders University of Rochester School of Medicine and Dentistry |
PDF (224.21 kB) | > |
Brochures |
CO₂ incubators Fact Sheet |
PDF (209.50 kB) | > |
White paper |
"Good laboratory practice" What is behind all this? |
PDF (246.52 kB) | > |
White paper |
Cell cultivation without contamination Hot air sterilization and other means of contamination control in CO₂ incubators |
PDF (299.86 kB) | > |
White paper |
Validation and Qualification In the regulated environment |
PDF (499.17 kB) | > |
Options & Accessories |
Stacking options for BINDER CO₂ incubators C | CB series |
PDF (152.82 kB) | > |
Buyer´s Guide |
CO₂ incubators 6 things to consider when buying CO₂ incubators |
PDF (425.35 kB) | > |