Model CB 170 | CO2 incubators with hot air sterilization and heat sterilizable CO2 sensor
Benefits
- Safe – cell cultures receive maximum protection against contamination
- Reliable – constant well-being conditions for the cells
- Smart – simple routine cleaning and convenient operation
- Economical – efficient operation without consumables
Product description
The powerful and versatile CB CO₂ incubator is suitable for cell-based assays in drug and medical research. This BINDER incubator is even suitable for complex cultivation experiments or individual environments with hypoxic conditions thanks to its comprehensive assortment of options and accessories.
Important characteristics
- Optimized double-pan humidification system with condensation protection
- Tried-and-tested anti-contamination concept with 180°C hot air sterilization
- Hot-air sterilizable CO₂ sensor with single-beam infrared technology
- Seamless inner chamber made of stainless steel with flanges as shelf support system
- Fanless interior with Venturi CO₂ gas mixing nozzle
- Intuitive touchscreen controller
- Internal data recording, can be read out in open format via USB interface
- Fault diagnosis system with visual and acoustic alarm
- Interfaces: Ethernet, USB, zero-voltage alarm contact
- Fail-safe CO₂ system for protecting the pH of cell cultures
Technical specifications
| Data | ||||||
| Designation | CB170-230V | CB170-230V-D | CB170-230V-O | CB170UL-120V | CB170UL-120V-D | CB170UL-120V-O |
| Article Number | 9640-0009 | 9640-0027 | 9640-0010 | 9640-0011 | 9640-0028 | 9640-0012 |
| Option model | Standard | with Access port 30 mm left | with O2 control | Standard | with Access port 30 mm left | with O2 control 0.2–20% |
| Performance Data Temperature | ||||||
| Temperature range | +4 °C above ambient temperature to 50 °C | +4 °C above ambient temperature to 50 °C | +6 °C above ambient temperature to 50 °C | +4 °C above ambient temperature to 50 °C | +4 °C above ambient temperature to 50 °C | +6 °C above ambient temperature to 50 °C |
| Temperature uniformity at 37°C | 0.3 ± K | 0.3 ± K | 0.3 ± K | 0.3 ± K | 0.3 ± K | 0.3 ± K |
| Temperature fluctuation at 37°C | 0.1 ± K | 0.1 ± K | 0.1 ± K | 0.1 ± K | 0.1 ± K | 0.1 ± K |
| Recovery time after door was opened for 30 s at 37°C | 6 min | 6 min | 6 min | 6 min | 6 min | 6 min |
| Performance Data Climate | ||||||
| Humidity range | 90 ...95 % r.F. | 90 ...95 % r.F. | 90 ...95 % r.F. | 90 ...95 % r.F. | 90 ...95 % r.F. | 90 ...95 % r.F. |
| Gas Data | ||||||
| CO₂ range | 0 ...20 Vol.-% CO₂ | 0 ...20 Vol.-% CO₂ | 0 ...20 Vol.-% CO₂ | 0 ...20 Vol.-% CO₂ | 0 ...20 Vol.-% CO₂ | 0 ...20 Vol.-% CO₂ |
| CO₂ measuring technology | IR | IR | IR | IR | IR | IR |
| CO₂ recovery time after door was opened for 30 s at 5 vol. % CO₂ | 5 min | 5 min | 5 min | 5 min | 5 min | 5 min |
| Standard O₂ control range | 0.2 ...20 Vol.-% O₂ | 0.2 ...20 Vol.-% O₂ | ||||
| O₂ control ranges with option: O₂ range | 10 ...90 Vol.-% O₂ | 10 ...90 Vol.-% O₂ | ||||
| O₂ recovery time after door was opened for 30 s at 5 vol. % O₂ | 10 min | 10 min | ||||
| Electrical data | ||||||
| Rated Voltage | 200...230 V | 200...230 V | 200...230 V | 100...120 V | 100...120 V | 100...120 V |
| Power frequency | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz |
| Nominal power | 1,4 kW | 1,4 kW | 1,4 kW | 1,4 kW | 1,4 kW | 1,4 kW |
| Unit fuse | 10,0 A | 10,0 A | 10,0 A | 16,0 A | 16,0 A | 16,0 A |
| Phase (Nominal voltage) | 1~ | 1~ | 1~ | 1~ | 1~ | 1~ |
| Dimensions and weights | ||||||
| Interior volume | 6 cu.ft. | 6 cu.ft. | 6 cu.ft. | 6 cu.ft. | 6 cu.ft. | 6 cu.ft. |
| Net weight of the unit (empty) | 209 lbs | 209 lbs | 209 lbs | 209 lbs | 209 lbs | 209 lbs |
| Load per rack | 22 lbs | 22 lbs | 22 lbs | 22 lbs | 22 lbs | 22 lbs |
| Permitted load | 66 lbs | 66 lbs | 66 lbs | 66 lbs | 66 lbs | 66 lbs |
| Wall clearance back | 3,94 in | 3,94 in | 3,94 in | 3,94 in | 3,94 in | 3,94 in |
| Wall clearance sidewise | 1,97 in | 1,97 in | 1,97 in | 1,97 in | 1,97 in | 1,97 in |
| Housing dimensions not incl. fittings and connections | ||||||
| Width net | 26.77 in | 26.77 in | 26.77 in | 26.77 in | 26.77 in | 26.77 in |
| Height net | 34.25 in | 34.25 in | 34.25 in | 34.25 in | 34.25 in | 34.25 in |
| Depth net | 28.15 in | 28.15 in | 28.15 in | 28.15 in | 28.15 in | 28.15 in |
| Internal Dimensions | ||||||
| Interior width | 22.05 in | 22.05 in | 22.05 in | 22.05 in | 22.05 in | 22.05 in |
| Interior height | 23.62 in | 23.62 in | 23.62 in | 23.62 in | 23.62 in | 23.62 in |
| Interior depth | 19.69 in | 19.69 in | 19.69 in | 19.69 in | 19.69 in | 19.69 in |
| Inner doors | 1 | 1 | 1 | 1 | 1 | 1 |
| Unit doors | 1 | 1 | 1 | 1 | 1 | 1 |
| Environment-specific data | ||||||
| Sound-pressure level | 41 dB(A) | 41 dB(A) | 41 dB(A) | 41 dB(A) | 41 dB(A) | 41 dB(A) |
| Energy consumption at 37°C | 55 Wh/h | 55 Wh/h | 55 Wh/h | 55 Wh/h | 55 Wh/h | 55 Wh/h |
| Fixtures | ||||||
| Number of shelves (std./max.) | 3/6 | 3/6 | 3/6 | 3/6 | 3/6 | 3/6 |
Downloads
Options, Accessories, Services
Sorry, no result could be found. Check the spelling or use a new search term.
Shaker „Professional“ - Shaker and controller equipped with LEMO connectors, exclusively for CB with electric access port, 100 – 240 V, 50/60 Hz
Shelf, perforated - Stainless steel, divided, for divided inner door
Copper interior fittings - Set consisting of 3 shelves (all-copper) and a water pan (copper-plated)
Base - the base equipped with casters is used for the secure positioning and leveling of a BINDER CO2 incubator
Stacking adapter - for the thermally isolated stacking of two BINDER CO2 incubators
Stacking frame - stable, vibration-free stacking frame on casters with stop brake for safe stacking of two CB series units
Shelf, perforated - Stainless steel
APT-COM™ 4 BASIC-Edition - for simple logging and documentation requirements with up to 5 networked units.
APT-COM™ 4 PROFESSIONAL-Edition - convenient unit and user management built on the BASIC edition. Suitable for networking up to 100 units.
APT-COM™ 4 GLP-Edition - for working under GLP-compliant conditions. Measured values are documented in a tamper-proof way in line with the requirements of FDA Regulation 21 CFR 11.
pH-neutral detergent - concentrated, for gentle remove of residual contaminants; 1 kg
Shaker „Universal“ - Shaker and controller connected via ribbon cable, universally applicable, 100 – 240 V, 50/60 Hz
Gas tank changer - external, BINDER Gas Supply Service, for connecting 2 gas tanks (CO2, N2 or O2), with audible and visual alarms, as well as zero-voltage alarm output
Sorry, no result could be found. Check the spelling or use a new search term.
Analog output 4-20 mA - for temperature and CO2 values (outputs not adjustable)
Access port with silicone plug - 30 mm, back
Access port with silicone plug - 30 mm, left
Access port with silicone plug - 30 mm, right
Electric access port - 8-pin, for low voltage with LEMO socket (coverable) and LEMO plug (max. 24 V – 2 A)
CELLROLL Set - modular, expandable roller bottle system for cell cultivation, 4 roller bottles
Inner door, divided - Cell therapy compartmentalization, consisting of 6 inner doors and three shelf levels with one partition wall each
Quick sample access - vewing window (13 x 25 cm) in the inner door for quick access
Sorry, no result could be found. Check the spelling or use a new search term.
BRONZE 3-year maintenance contract - Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate. 10% Discount on Spare Parts and Labor for any additional Services needed Wear + tear parts to be purchased or billed to customer. Travel to be quoted as separate.
SILVER 3-year maintenance contract - Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate 15% Discount on Spare Parts and Labor for any additional Services needed One additional courtesy visit per year can be used for service visit or operator training. Wear + tear parts to be purchased or billed to customer. Travel to be quoted separate.
GOLD 3-year maintenance contract - Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate of Temperature. 25% Discount on Spare Parts and Labor for any additional Services needed. One additional courtesy visit per year can be used for service visit or operator. Wear + tear parts to be purchased or billed to customer. Travel to be quoted separate.
Unit installation - Connect the unit to the customer-side connections (electricity, water, wastewater, gas), basic functions check, brief operating instructions. (excl.: unpacking, setup, controller instructions, programming, installation work) Travel to be quoted as separate.
Unit instructions - Instruction regarding operating principle and basic functions of the unit, operation of the control electronics including programming. Travel to be quoted as separate Limited to 3 hours.
Preventive maintenance - One-off maintenance service in accordance with maintenance schedule. Visual inspection of mechanical and electrical components, testing of all key functions. Checking a test temperature specified by the user in center of usable space without certificate. Wear + tear parts need to be purchased or billed to customer. Travel to be quoted as separate.
CO₂ calibration - CO₂ calibration at a specified value, measurements are taken with analyzed test gas at 5%, including certificate. Travel to be quoted separate.
Temperature calibration - Calibration of one (1) test temperature specified by the user in center of chamber, including certificate Travel to be quoted separate.
Temperature calibration - Extension of calibration of one (1) additional test temperature specified by the user in the center of the usable space, including certificate Travel to be quoted separate.
Temperature measurement, 9 measuring points - Temperature measurement with 9 measuring points with a set value specified by the user, including certificate. Travel to be quoted separate. A total of 3 shelvesare required.
Temperature measurement, 18 measuring points - Temperature measurement with 18 measuring points with a set value specified by the user, including certificate. Travel to be quoted separate. A total of 2 shelvesare required.
Temperature measurement, 27 measuring points - Temperature measurement with 27 measuring points with a set value specified by the user, including certificate. Travel to be quoted separate. A total of 3 shelvesare required.
Execution of IQ/OQ - Execution of IQ/OQ in accordance with qualification folder. Travel to be quoted separate.
Execution of IQ/OQ/PQ - Execution of IQ/OQ/PQ in accordance with qualification folder. Travel to be quoted separate.
1-year warranty extension - The warranty is extended by 1 year from the delivery date, wear parts are excluded
O₂ calibration - O₂ calibration with 1 measuring point in center of chamber at a specified O₂ percentage value, including certificate. Travel to be quoted separate.