Benefits
- Best energy efficiency on the market
- Excellent temporal and spatial temperature accuracy
- USB connection for recording data
- Temperature range up to +300 °C
Product description
A BINDER FD series Avantgarde.Line heating oven is always used when fast drying and sterilization is required. Thanks to its fully homogeneous temperature distribution, quick dynamics and powerful fan, this heating oven saves valuable time.
Important characteristics
- Temperature range: +10°C above ambient temperature to +300 °C
- High temperature accuracy thanks to APT.line™ technology
- Forced convection
- Controller with LCD display
- Electromechanical control of the exhaust air flap
- 2 chrome-plated racks
- Units up to 115 L are stackable
- Class 2 independent temperature safety device (DIN 12880) with visual temperature alarm
- Ergonomic handle design
- USB port for recording data
Technical specifications
| Data | ||
| Designation | FD056-230V | FD056UL-120V |
| Article Number | 9010-0303 | 9010-0304 |
| Option model | Standard | Standard |
| Performance Data Temperature | ||
| Temperature range | +10 °C above ambient temperature to 300 °C | +10 °C above ambient temperature to 300 °C |
| Temperature uniformity at 150°C | 1.7 ± K | 1.7 ± K |
| Temperature fluctuation at 150°C | 0.3 ± K | 0.3 ± K |
| Heating up time to 150°C | 15 min | 15 min |
| Recovery time after door was opened for 30 s at 150°C | 4 min | 4 min |
| Air change data | ||
| Air change rate at 100°C | 80 x/h | 80 x/h |
| Electrical data | ||
| Rated Voltage | 230 V | 120 V |
| Power frequency | 50/60 Hz | 60 Hz |
| Nominal power | 1,1 kW | 1,2 kW |
| Unit fuse | 6,3 A | 12,5 A |
| Phase (Nominal voltage) | 1~ | 1~ |
| Dimensions and weights | ||
| Interior volume | 2 cu.ft. | 2 cu.ft. |
| Net weight of the unit (empty) | 90 lbs | 90 lbs |
| Load per rack | 66 lbs | 66 lbs |
| Permitted load | 154 lbs | 154 lbs |
| Wall clearance back | 6,3 in | 6,3 in |
| Wall clearance sidewise | 3,94 in | 3,94 in |
| Housing dimensions not incl. fittings and connections | ||
| Width net | 22.05 in | 22.05 in |
| Height net | 24.61 in | 24.61 in |
| Depth net | 22.24 in | 22.24 in |
| Internal Dimensions | ||
| Interior width | 15.75 in | 15.75 in |
| Interior height | 17.32 in | 17.32 in |
| Interior depth | 13.58 in | 13.58 in |
| Unit doors | 1 | 1 |
| Environment-specific data | ||
| Sound-pressure level | 43 dB(A) | 43 dB(A) |
| Energy consumption at 100°C | 180 Wh/h | 180 Wh/h |
| Energy consumption at 150°C | 290 Wh/h | 290 Wh/h |
| Fixtures | ||
| Number of shelves (std./max.) | 2/4 | 2/4 |
Downloads
Options, Accessories, Services
Sorry, no result could be found. Check the spelling or use a new search term.
Rack - chrome plated
Rack - stainless steel
Shelf, perforated - Stainless steel
stable cart, casters with locking brakes, dimensions: W 1,000 x D 800 x H 780 mm
APT-COM™ 4 BASIC-Edition - for simple logging and documentation requirements with up to 5 networked units.
APT-COM™ 4 PROFESSIONAL-Edition - convenient unit and user management built on the BASIC edition. Suitable for networking up to 100 units.
APT-COM™ 4 GLP-Edition - for working under GLP-compliant conditions. Measured values are documented in a tamper-proof way in line with the requirements of FDA Regulation 21 CFR 11.
pH-neutral detergent - concentrated, for gentle remove of residual contaminants; 1 kg
Sorry, no result could be found. Check the spelling or use a new search term.
HEPA air filter - On fresh air supply for unit; filter classification H14 (acc. to. EN 1822-1:2009, > 99.995% at 0.3 µm); not in conjunction with reinforced heating output, reinforced fan
Heating output, reinforced - 120/230 V option model, For faster heating up time and improved recovery time; max. 300°C
Access port with silicone plug - 30 mm, right
Access port with silicone plug - 30 mm, left
Access port with silicone plug - 50 mm, right
Access port with silicone plug - 50 mm, left
Access port with silicone plug - 10 mm, top
Access port with silicone plug - 10 mm, right
Access port with silicone plug - 10 mm, left
Access port with silicone plug - 30 mm, top
Access port with silicone plug - 50 mm, top
Pt 100 temperature sensor - additional flexible Pt 100, interior, for displaying the temperature on the unit display
Door lock - lockable door handle
Access port with silicone plug - 100 mm, top
Viewing window and interior lighting - 230 V option model, viewing window (triple insulating glass) in door, 240 x 240 mm, and 15 W interior
Sorry, no result could be found. Check the spelling or use a new search term.
Temperature calibration - Extension of calibration of one (1) additional test temperature specified by the user in the center of the usable space, including certificate Travel to be quoted separate.
Temperature measurement, 9 measuring points - Temperature measurement with 9 measuring points with a set value specified by the user, including certificate. Travel to be quoted separate. A total of 3 shelvesare required.
Temperature measurement, 18 measuring points - Temperature measurement with 18 measuring points with a set value specified by the user, including certificate. Travel to be quoted separate. A total of 2 shelvesare required.
Temperature measurement, 27 measuring points - Temperature measurement with 27 measuring points with a set value specified by the user, including certificate. Travel to be quoted separate. A total of 3 shelvesare required.
Execution of IQ/OQ/PQ - Execution of IQ/OQ/PQ in accordance with qualification folder. Travel to be quoted separate.
BRONZE 3-year maintenance contract - Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate. 10% Discount on Spare Parts and Labor for any additional Services needed Wear + tear parts to be purchased or billed to customer. Travel to be quoted as separate.
Unit installation - Connect the unit to the customer-side connections (electricity, water, wastewater, gas), basic functions check, brief operating instructions. (excl.: unpacking, setup, controller instructions, programming, installation work) Travel to be quoted as separate.
Unit instructions - Instruction regarding operating principle and basic functions of the unit, operation of the control electronics including programming. Travel to be quoted as separate Limited to 3 hours.
1-year warranty extension - The warranty is extended by 1 year from the delivery date, wear parts are excluded
Execution of IQ/OQ - Execution of IQ/OQ in accordance with qualification folder. Travel to be quoted separate.
SILVER 3-year maintenance contract - Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate 15% Discount on Spare Parts and Labor for any additional Services needed One additional courtesy visit per year can be used for service visit or operator training. Wear + tear parts to be purchased or billed to customer. Travel to be quoted separate.
GOLD 3-year maintenance contract - Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate of Temperature. 25% Discount on Spare Parts and Labor for any additional Services needed. One additional courtesy visit per year can be used for service visit or operator. Wear + tear parts to be purchased or billed to customer. Travel to be quoted separate.
Preventive maintenance - One-off maintenance service in accordance with maintenance schedule. Visual inspection of mechanical and electrical components, testing of all key functions. Checking a test temperature specified by the user in center of usable space without certificate. Wear + tear parts need to be purchased or billed to customer. Travel to be quoted as separate.
Temperature calibration - Calibration of one (1) test temperature specified by the user in center of chamber, including certificate Travel to be quoted separate.
Measurement of air exchange rate - including certificate (in accordance with ASTM D5374)