Model 115
Dimensions
Product image
Product image

Model FD 115 | Drying and heating chambers with forced convection

Benefits
  • Best energy efficiency on the market
  • Excellent temporal and spatial temperature accuracy
  • USB connection for recording data
  • Temperature range up to +300 °C

Configure your product with options and accessories and request it directly here.

Product description

A BINDER FD series Avantgarde.Line heating oven is always used when fast drying and sterilization is required. Thanks to its fully homogeneous temperature distribution, quick dynamics and powerful fan, this heating oven saves valuable time.

Important characteristics

  • Temperature range: +10°C above ambient temperature to +300 °C
  • High temperature accuracy thanks to APT.line™ technology
  • Forced convection
  • Controller with LCD display
  • Electromechanical control of the exhaust air flap
  • 2 chrome-plated racks
  • Units up to 115 L are stackable
  • Class 2 independent temperature safety device (DIN 12880) with visual temperature alarm
  • Ergonomic handle design
  • USB port for recording data

Technical specifications

Data
DesignationFD115-230VFD115UL-120V
Article Number9010-03059010-0306
Option model

Standard

Standard

Performance Data Temperature
Temperature range+10 °C above ambient temperature to 300 °C+10 °C above ambient temperature to 300 °C
Temperature uniformity at 150°C1.7 ± K1.7 ± K
Temperature fluctuation at 150°C0.3 ± K0.3 ± K
Heating up time to 150°C18 min18 min
Recovery time after door was opened for 30 s at 150°C4 min4 min
Air change data
Air change rate at 100°C32 x/h32 x/h
Electrical data
Rated Voltage230 V120 V
Power frequency50/60 Hz60 Hz
Nominal power1,3 kW1,4 kW
Unit fuse6,3 A12,5 A
Phase (Nominal voltage)1~1~
Dimensions and weights
Interior volume4 cu.ft.4 cu.ft.
Net weight of the unit (empty)119 lbs119 lbs
Load per rack66 lbs66 lbs
Permitted load331 lbs331 lbs
Wall clearance back6,3 in6,3 in
Wall clearance sidewise3,94 in3,94 in
Housing dimensions not incl. fittings and connections
Width net27.95 in27.95 in
Height net28.94 in28.94 in
Depth net23.82 in23.82 in
Internal Dimensions
Interior width21.65 in21.65 in
Interior height21.65 in21.65 in
Interior depth15.16 in15.16 in
Unit doors11
Environment-specific data
Sound-pressure level43 dB(A)43 dB(A)
Energy consumption at 100°C215 Wh/h215 Wh/h
Energy consumption at 150°C340 Wh/h340 Wh/h
Fixtures
Number of shelves (std./max.)2/52/5

Downloads

Drying and heating chambers

ED | ED-S | FD | FD-S | FED | FP | M series

pdf, 2.21 MB

Drying and heating chambers (FD series) - Cocoa beans hitting the spot

Seguine Cacao Cocoa & Chocolate Advisors

pdf, 1.17 MB

Drying and heating chambers (ED | FD series) - Testing the functionality and service life of cables

U. I. Lapp GmbH

pdf, 189.08 KB

Drying and heating chambers (FD series) - From toothbrushes to tool handles and seals in vehicles

KRAIBURG TPE GmbH & Co. KG

pdf, 701.49 KB

Drying and heating chambers (FP series) - Drying chambers, constant climate chambers, dynamic climate chambers and cooling incubators test the service life of MinebeaMitsumi spindle motors

MinebeaMitsumi Technology Center Europe GmbH

pdf, 479.77 KB

BD | BF | ED | FD | FED series

pdf, 18.66 MB

Quick Start Guide BD | BF | ED | FD | FED series

pdf, 1.65 MB

Data Sheet Model FD 115

pdf, 154.99 KB

Options, Accessories, Services

Sorry, no result could be found. Check the spelling or use a new search term.

Rubber pads

Set anti-slip feet

8012-2030

Rack

Max. load per rack 30 kg. chrome plated

8012-2040

Shelves

Rack - chrome plated

Rack

Max. load per rack 30 kg. stainless steel

8012-2168

Shelves

Rack - stainless steel

Shelf, perforated

Max. load per rack 30 kg. Stainless steel

8012-2176

Shelf

Shelf, perforated - Stainless steel

Table on castors

Stable cart, casters with locking brakes, dimensions: W 1,000 x D 800 x H 780 mm

9051-0018

Tischwagen

stable cart, casters with locking brakes, dimensions: W 1,000 x D 800 x H 780 mm

APT-COM™ 4 BASIC-Edition

For simple logging and documentation requirements with up to 5 networked units.. version 4, BASIC edition

9053-0039

Multi Management Software APT-COM™

APT-COM™ 4 BASIC-Edition - for simple logging and documentation requirements with up to 5 networked units.

APT-COM™ 4 PROFESSIONAL-Edition

Convenient unit and user management built on the BASIC edition. Suitable for networking up to 100 units.. version 4, PROFESSIONAL edition

9053-0040

Multi Management Software APT-COM™

APT-COM™ 4 PROFESSIONAL-Edition - convenient unit and user management built on the BASIC edition. Suitable for networking up to 100 units.

APT-COM™ 4 GLP-Edition

For working under GLP-compliant conditions. Measured values are documented in a tamper-proof way in line with the requirements of FDA Regulation 21 CFR 11.. version 4, GLP edition

9053-0042

Multi Management Software APT-COM™

APT-COM™ 4 GLP-Edition - for working under GLP-compliant conditions. Measured values are documented in a tamper-proof way in line with the requirements of FDA Regulation 21 CFR 11.

pH-neutral detergent

Concentrated, for gentle remove of residual contaminants; 1 kg

8012-2250

1002-0016-Neutralreiniger-100x85_Web_670x515.jpg

pH-neutral detergent - concentrated, for gentle remove of residual contaminants; 1 kg

Qualification documents

IQ/OQ documents – supporting documents for validation performed by customers, consisting of: IQ/OQ checklists incl. calibration guide and comprehensive unit documentation; parameters: temperature, CO2, O2, pressure, depending on unit. Hard copy inside folder

7007-0001

Qualification documents

IQ/OQ documents – supporting documents for validation performed by customers, consisting of: IQ/OQ checklists incl. calibration guide and comprehensive unit documentation; parameters: temperature, CO2, O2, pressure, depending on unit. Digital in PDF format

7057-0001

Qualification documents

IQ/OQ/PQ documents – supporting documents for validation performed by customers, according to customer requirements, PQ section added to qualification folder IQ/OQ; parameters: temperature, CO2, O2 – or pressure, depending on unit. Hard copy inside folder

7007-0005

Qualification documents

IQ/OQ/PQ documents – supporting documents for validation performed by customers, according to customer requirements, PQ section added to qualification folder IQ/OQ; parameters: temperature, CO2, O2 – or pressure, depending on unit. Digital in PDF format

7057-0005

Sorry, no result could be found. Check the spelling or use a new search term.

Ethernet interface

For Multi Management Software APT-COM™

8012-0988

Calibration certificate, expanded

For temperature; for extending the measurement in center of chamber to include another test temperature

8012-1116

Calibration certificate, temperature

For temperature, measurement in center of chamber at specified temperature

8012-1135

Measurement of air exchange rate

In accordance with ASTM D5374, definition and protocol according to ambient temperature

8012-1195

Access port with silicone plug

Right. 30 mm

8012-1015

Access port with silicone plug

Access port with silicone plug - 30 mm, right

Access port with silicone plug

Left. 30 mm

8012-1016

Access port with silicone plug

Access port with silicone plug - 30 mm, left

Access port with silicone plug

Right. 50 mm

8012-1019

Access port with silicone plug

Access port with silicone plug - 50 mm, right

Access port with silicone plug

Left. 50 mm

8012-1020

Access port with silicone plug

Access port with silicone plug - 50 mm, left

Access port with silicone plug

Top. 10 mm

8012-1263

Access port with silicone plug

Access port with silicone plug - 10 mm, top

Access port with silicone plug

Right. 10 mm

8012-1269

Access port with silicone plug

Access port with silicone plug - 10 mm, right

Access port with silicone plug

Left. 10 mm

8012-1276

Access port with silicone plug

Access port with silicone plug - 10 mm, left

Access port with silicone plug

Top. 30 mm

8012-1364

Access port with silicone plug

Access port with silicone plug - 30 mm, top

Access port with silicone plug

Top. 50 mm

8012-1380

Access port with silicone plug

Access port with silicone plug - 50 mm, top

Calibration certificate, temperature

Temperature measurement incl. certificate, 9 measuring points at specified temperature

8012-1552

Calibration certificate, temperature

Temperature measurement incl. certificate, 15- 18 measuring points at specified temperature

8012-1573

Calibration certificate, temperature

Temperature measurement incl. certificate and 27 measuring points at specified temperature

8012-1594

Pt 100 temperature sensor

Additional flexible Pt 100, interior, for displaying the temperature on the unit display

8012-1620

Pt 100 temperature sensor

Pt 100 temperature sensor - additional flexible Pt 100, interior, for displaying the temperature on the unit display

Analog output 4-20 mA

For temperature values (output not adjustable)

8012-1624

Alarm function for overheating

Switchable acoustic alarm, with adjustable limit value on the independent temperature safety device

8012-1636

Clock

Battery-backed

8012-1641

Class 3.1 independent temperature safety device

With visual alarm (DIN 12880)

8012-1643

Door lock

Lockable door handle

8012-1665

Door lock

Door lock - lockable door handle

Access port with silicone plug

Top. 100 mm

8012-1671

Access port with silicone plug

Access port with silicone plug - 100 mm, top

Access port with silicone plug

Left. 100 mm

8012-1027

Access port with silicone plug

Access port with silicone plug - 100 mm, left

Access port with silicone plug

Right. 100 mm

8012-1028

Access port with silicone plug

Access port with silicone plug - 100 mm, right

HEPA air filter

On fresh air supply for unit; filter classification H14 (acc. to. EN 1822-1:2009, > 99.995% at 0.3 µm); not in conjunction with reinforced heating output, reinforced fan

8012-1051

HEPA air filter

HEPA air filter - On fresh air supply for unit; filter classification H14 (acc. to. EN 1822-1:2009, > 99.995% at 0.3 µm); not in conjunction with reinforced heating output, reinforced fan

Inner chamber, reinforced

Max. total load 170 kg

8012-1054

Door gasket

Made of FKM, silicone-free

8012-1650

Gas-tight option model

Incl. additional measures for the greatest possible impermeability to gas; not in conjunction with access port or interior lighting option  

8012-1685

Inert gas connection

With gas inlet and outlet, Ø 10 mm, incl. additional measures for the greatest possible impermeability to gas; not in conjunction with access port or interior lighting option

8012-1691

Interior lighting

With 27 W light bulb. 230/240 V option model

8012-1628

Heating output, reinforced

For faster heating up time and improved recovery time; max. 300°C. 120/230 V option model

8012-1057

Reinforced heating output

Heating output, reinforced - 120/230 V option model, For faster heating up time and improved recovery time; max. 300°C

Viewing window and interior lighting

Viewing window (triple insulating glass) in door, 370 x 370 mm, and 15 W interior. 230 V option model

8012-1704

Viewing window in the door

Viewing window and interior lighting - 230 V option model, viewing window (triple insulating glass) in door, 370 x 370 mm, and 15 W interior

Sorry, no result could be found. Check the spelling or use a new search term.

Temperature calibration

Extension of calibration of one (1) additional test temperature specified by the user in the center of the usable space, including certificate Travel to be quoted separate

DL30-0102

Services

Temperature calibration - Extension of calibration of one (1) additional test temperature specified by the user in the center of the usable space, including certificate Travel to be quoted separate.

Temperature measurement, 9 measuring points

Temperature measurement with 9 measuring points with a set value specified by the user, including certificate. Travel to be quoted separate.  A total of 3 shelvesare required

DL30-0109

Services

Temperature measurement, 9 measuring points - Temperature measurement with 9 measuring points with a set value specified by the user, including certificate. Travel to be quoted separate.  A total of 3 shelvesare required.

Temperature measurement, 18 measuring points

Temperature measurement with 18 measuring points with a set value specified by the user, including certificate. Travel to be quoted separate.  A total of 2 shelvesare required

DL30-0118

Services

Temperature measurement, 18 measuring points - Temperature measurement with 18 measuring points with a set value specified by the user, including certificate. Travel to be quoted separate.  A total of 2 shelvesare required.

Temperature measurement, 27 measuring points

Temperature measurement with 27 measuring points with a set value specified by the user, including certificate. Travel to be quoted separate.  A total of 3 shelvesare required

DL30-0127

Services

Temperature measurement, 27 measuring points - Temperature measurement with 27 measuring points with a set value specified by the user, including certificate. Travel to be quoted separate.  A total of 3 shelvesare required.

Execution of IQ/OQ/PQ

Execution of IQ/OQ/PQ in accordance with qualification folder. Travel to be quoted separate

DL44-0500

Services

Execution of IQ/OQ/PQ - Execution of IQ/OQ/PQ in accordance with qualification folder. Travel to be quoted separate.

BRONZE 3-year maintenance contract

Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate. 10% Discount on Spare Parts and Labor for any additional Services needed Wear + tear parts to be purchased or billed to customer. Travel to be quoted as separate

DL20-0720

Services

BRONZE 3-year maintenance contract - Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate. 10% Discount on Spare Parts and Labor for any additional Services needed Wear + tear parts to be purchased or billed to customer. Travel to be quoted as separate.

Unit installation

Connect the unit to the customer-side connections (electricity, water, wastewater, gas), basic functions check, brief operating instructions. (excl.: unpacking, setup, controller instructions, programming, installation work) Travel to be quoted as separate

DL10-0100

Services

Unit installation - Connect the unit to the customer-side connections (electricity, water, wastewater, gas), basic functions check, brief operating instructions. (excl.: unpacking, setup, controller instructions, programming, installation work) Travel to be quoted as separate.

Unit instructions

Instruction regarding operating principle and basic functions of the unit, operation of the control electronics including programming. Travel to be quoted as separate Limited to 3 hours

DL10-0500

Services

Unit instructions - Instruction regarding operating principle and basic functions of the unit, operation of the control electronics including programming. Travel to be quoted as separate Limited to 3 hours.

1-year warranty extension

The warranty is extended by 1 year from the delivery date, wear parts are excluded

DL50-0010

Services

1-year warranty extension - The warranty is extended by 1 year from the delivery date, wear parts are excluded

Execution of IQ/OQ

Execution of IQ/OQ in accordance with qualification folder. Travel to be quoted separate

DL40-0100

Services

Execution of IQ/OQ - Execution of IQ/OQ in accordance with qualification folder. Travel to be quoted separate.

SILVER 3-year maintenance contract

Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate 15% Discount on Spare Parts and Labor for any additional Services needed One additional courtesy visit per year can be used for service visit or operator training. Wear + tear parts to be purchased or billed to customer. Travel to be quoted separate

DL20-0810

Services

SILVER 3-year maintenance contract - Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate 15% Discount on Spare Parts and Labor for any additional Services needed One additional courtesy visit per year can be used for service visit or operator training. Wear + tear parts to be purchased or billed to customer. Travel to be quoted separate.

GOLD 3-year maintenance contract

Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate of Temperature. 25% Discount on Spare Parts and Labor for any additional Services needed. One additional courtesy visit per year can be used for service visit or operator. Wear + tear parts to be purchased or billed to customer. Travel to be quoted separate

DL20-0910

Services

GOLD 3-year maintenance contract - Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate of Temperature. 25% Discount on Spare Parts and Labor for any additional Services needed. One additional courtesy visit per year can be used for service visit or operator. Wear + tear parts to be purchased or billed to customer. Travel to be quoted separate.

Preventive maintenance 

One-off maintenance service in accordance with maintenance schedule. Visual inspection of mechanical and electrical components, testing of all key functions. Checking a test temperature specified by the user in center of usable space without certificate. Wear + tear parts need to be purchased or billed to customer. Travel to be quoted as separate

DL20-0602

Services

Preventive maintenance  - One-off maintenance service in accordance with maintenance schedule. Visual inspection of mechanical and electrical components, testing of all key functions. Checking a test temperature specified by the user in center of usable space without certificate. Wear + tear parts need to be purchased or billed to customer. Travel to be quoted as separate.

Temperature calibration

Calibration of one (1) test temperature specified by the user in center of chamber, including certificate Travel to be quoted separate

DL30-0120

Services

Temperature calibration - Calibration of one (1) test temperature specified by the user in center of chamber, including certificate Travel to be quoted separate.

Measurement of air exchange rate

Including certificate (in accordance with ASTM D5374)

DL33-0000

Services

Measurement of air exchange rate - including certificate (in accordance with ASTM D5374)

Suggested products

Compare products:

Or add another product.