Benefits
- High temperature accuracy thanks to APT.line™ technology
- User-friendly controller with large display
- Computer interface: Ethernet
- Class 2 independent adjustable temperature safety device (DIN 12880) and class 3.1 independent temperature safety device (DIN 12880) with visual/acoustic alarm available for selection on the controller
Product description
A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying times and particularly fast heating – even for chambers under full loads.
Important characteristics
- Temperature range: +10°C above ambient temperature up to +300°C
- High temperature accuracy thanks to APT.line™ technology
- Adjustable fan speed
- Controller with interval and real-time programming via APT-COM or RD4 program editor
- Electromechanical control of the exhaust air flap
- 2 chrome-plated racks
- Units up to 115 liters are stackable
- Class 2 independent adjustable temperature safety device (DIN 12880) and class 3.1 independent temperature safety device (DIN 12880) with visual/acoustic alarm available for selection on the controller
- Ergonomic handle design
- Computer interface: Ethernet
- Internal data logger, measured values can be read out in open format via USB
Technical specifications
| Data | ||
| Article Number | 9010-0363 | 9010-0367 |
| Designation | FP056-230V | FP056UL-120V |
| Option model | Standard | Standard |
| Performance Data Temperature | ||
| Temperature range | +10 °C above ambient temperature to 300 °C | +10 °C above ambient temperature to 300 °C |
| Temperature uniformity at 150°C | 1.4 ± K | 1.4 ± K |
| Temperature fluctuation at 150°C | 0.4 ± K | 0.4 ± K |
| Heating up time to 150°C | 15 min | 15 min |
| Recovery time after door was opened for 30 s at 150°C | 4 min | 4 min |
| Air change data | ||
| Air change rate at 100°C | 80 x/h | 80 x/h |
| Electrical data | ||
| Rated Voltage | 230 V | 120 V |
| Power frequency | 50/60 Hz | 60 Hz |
| Nominal power | 1,2 kW | 1,2 kW |
| Unit fuse | 10,0 A | 16,0 A |
| Phase (Nominal voltage) | 1~ | 1~ |
| Dimensions and weights | ||
| Interior volume | 2 cu.ft. | 2 cu.ft. |
| Net weight of the unit (empty) | 90 lbs | 90 lbs |
| Load per rack | 66 lbs | 66 lbs |
| Permitted load | 154 lbs | 154 lbs |
| Wall clearance back | 6,3 in | 6,3 in |
| Wall clearance sidewise | 3,94 in | 3,94 in |
| Housing dimensions not incl. fittings and connections | ||
| Width net | 22.05 in | 22.05 in |
| Height net | 24.49 in | 24.49 in |
| Depth net | 23.46 in | 23.46 in |
| Internal Dimensions | ||
| Interior width | 15.75 in | 15.75 in |
| Interior height | 17.32 in | 17.32 in |
| Interior depth | 13.46 in | 13.46 in |
| Unit doors | 1 | 1 |
| Environment-specific data | ||
| Sound-pressure level | 43 dB(A) | 43 dB(A) |
| Energy consumption at 100°C | 180 Wh/h | 180 Wh/h |
| Energy consumption at 150°C | 290 Wh/h | 290 Wh/h |
| Fixtures | ||
| Number of shelves (std./max.) | 2/4 | 2/4 |
Options, accessories & services
Sorry, no result could be found. Check the spelling or use a new search term.
HEPA air filter - On fresh air supply for unit; filter classification H14 (acc. to. EN 1822-1:2009, > 99.995% at 0.3 µm); not in conjunction with reinforced heating output, reinforced fan
Door lock - lockable door handle
Access port with silicone plug - 10 mm, left
Access port with silicone plug - 10 mm, top
Access port with silicone plug - 10 mm, right
Access port with silicone plug - 100 mm, top
Access port with silicone plug - 30 mm, left
Access port with silicone plug - 30 mm, top
Access port with silicone plug - 30 mm, right
Access port with silicone plug - 50 mm, left
Access port with silicone plug - 50 mm, top
Access port with silicone plug - 50 mm, right
Pt 100 temperature sensor - additional flexible Pt 100, interior, for displaying the temperature on the unit display
Sorry, no result could be found. Check the spelling or use a new search term.
BRONZE 3-year maintenance contract - Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts
SILVER 3-year maintenance contract - Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts, testing of all key functions, calibration of one test temperature specified by the user in the center of the usable space, without certificate
GOLD 3-year maintenance contract - Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts, testing of all key functions, replacement of wear parts, calibration of one test temperature specified by the user in the center of the usable space, including certificate
Preventive maintenance - One-off maintenance service in accordance with maintenance schedule. Visual inspection of mechanical and electrical components, testing of all key functions. Checking a test temperature specified by the user in center of usable space without certificate. Wear + tear parts need to be purchased or billed to customer. Travel to be quoted as separate.
Temperature calibration - Calibration of one (1) test temperature specified by the user in center of chamber, including certificate Travel to be quoted separate.
Temperature calibration - Extension of calibration of one (1) additional test temperature specified by the user in the center of the usable space, including certificate Travel to be quoted separate.
Temperature measurement, 9 measuring points - Temperature measurement with 9 measuring points with a set value specified by the user, including certificate. Travel to be quoted separate. A total of 3 shelvesare required.
Temperature measurement, 18 measuring points - Temperature measurement with 18 measuring points with a set value specified by the user, including certificate. Travel to be quoted separate. A total of 2 shelvesare required.
Temperature measurement, 27 measuring points - Temperature measurement with 27 measuring points with a set value specified by the user, including certificate. Travel to be quoted separate. A total of 3 shelvesare required.
Execution of IQ/OQ - Execution of IQ/OQ in accordance with qualification folder. Travel to be quoted separate.
Execution of IQ/OQ/PQ - Execution of IQ/OQ/PQ in accordance with qualification folder. Travel to be quoted separate.
1-year warranty extension - The warranty is extended by 1 year from the delivery date, wear parts are excluded
Unit installation - Connect the unit to the customer-side connections (electricity, water, wastewater, gas), basic functions check, brief operating instructions. (excl.: unpacking, setup, controller instructions, programming, installation work) Travel to be quoted as separate.
Unit instructions - Instruction regarding operating principle and basic functions of the unit, operation of the control electronics including programming. Travel to be quoted as separate Limited to 3 hours.
Sorry, no result could be found. Check the spelling or use a new search term.
Shelf, perforated - Stainless steel
Rack - stainless steel
Rack - chrome plated
stable cart, casters with locking brakes, dimensions: W 1,000 x D 800 x H 780 mm
pH-neutral detergent - concentrated, for gentle remove of residual contaminants; 1 kg
APT-COM™ 4 BASIC-Edition - for simple logging and documentation requirements with up to 5 networked units.
APT-COM™ 4 PROFESSIONAL-Edition - convenient unit and user management built on the BASIC edition. Suitable for networking up to 100 units.
APT-COM™ 4 GLP-Edition - for working under GLP-compliant conditions. Measured values are documented in a tamper-proof way in line with the requirements of FDA Regulation 21 CFR 11.
Rack accessories - fasteners (1 set of 4) for additional security of racks