Model 400
Dimensions
Product image
Product image

Model ED 400 | Drying and heating chambers with natural convection

Benefits
  • Uniform drying conditions thanks to APT.line™ technology
  • Identical test conditions throughout the chamber interior independent of sample size and quantity
  • Outstanding thermal insulation saves operation costs

Configure your product with options and accessories and request it directly here.

Product description

The strengths of a BINDER ED series drying chamber include routine drying and sterilization tasks up to +300 °C. Thanks to the natural convection, all thermal processes which use this drying chamber are highly efficient. The ED series ensures fast, uniform drying.

Important characteristics

  • Temperature range: +5°C above ambient temperature to +300 °C
  • APT.line™ preheating chamber technology
  • Natural convection
  • Adjustable exhaust air flap
  • Controller with timer functions
  • 2 chrome-plated racks
  • Class 2 independent adjustable temperature safety device (DIN 12880) with visual alarm

Technical specifications

Data
DesignationED400-400V-IED400UL-208V-I
Article Number9010-00759010-0168
Option modelwith RS 422with RS 422
Performance Data Temperature
Temperature range+5 °C above ambient temperature to 300 °C+5 °C above ambient temperature to 300 °C
Temperature uniformity at 150°C3.0 ± K3.0 ± K
Temperature fluctuation at 150°C0.5 ± K0.5 ± K
Heating up time to 150°C71 min71 min
Recovery time after door was opened for 30 s at 150°C31 min31 min
Air change data
Air change rate at 150°C10 x/h10 x/h
Electrical data
Rated Voltage400 V208 V
Power frequency50/60 Hz60 Hz
Nominal power3,4 kW3,4 kW
Unit fuse16,0 A16,0 A
Phase (Nominal voltage)3~/N/PE3~
Dimensions and weights
Interior volume400 L400 L
Net weight of the unit (empty)125 kg125 kg
Load per rack35 kg35 kg
Permitted load90 kg90 kg
Wall clearance back160 mm160 mm
Wall clearance sidewise100 mm100 mm
Housing dimensions not incl. fittings and connections
Width net1,235 mm1,235 mm
Height net1,025 mm1,025 mm
Depth net765 mm765 mm
Internal Dimensions
Interior width1,000 mm1,000 mm
Interior height800 mm800 mm
Interior depth520 mm520 mm
Unit doors22
Environment-specific data
Energy consumption at 150°C672 Wh/h672 Wh/h
Fixtures
Number of shelves (std./max.)2/102/10

Downloads

Drying and heating chambers

ED | ED-S | FD | FD-S | FED | FP | M series

pdf, 2.21 MB

Drying and heating chambers (FP series) - Drying chambers, constant climate chambers, dynamic climate chambers and cooling incubators test the service life of MinebeaMitsumi spindle motors

MinebeaMitsumi Technology Center Europe GmbH

pdf, 479.77 KB

BD | ED |  FD series

pdf, 10.14 MB

Data Sheet Model ED 400

pdf, 450.83 KB

Options, Accessories, Services

Sorry, no result could be found. Check the spelling or use a new search term.

Rack

Chrome plated

8012-2036

Shelves

Rack - chrome plated

Rack

Stainless steel

8012-2159

Shelves

Rack - stainless steel

Shelf, perforated

Stainless steel

8012-2162

Shelf

Shelf, perforated - Stainless steel

APT-COM™ 4 BASIC-Edition

For simple logging and documentation requirements with up to 5 networked units.. version 4, BASIC edition 

9053-0039

Multi Management Software APT-COM™

APT-COM™ 4 BASIC-Edition - for simple logging and documentation requirements with up to 5 networked units.

APT-COM™ 4 PROFESSIONAL-Edition

Convenient unit and user management built on the BASIC edition. Suitable for networking up to 100 units.. version 4, PROFESSIONAL edition

9053-0040

Multi Management Software APT-COM™

APT-COM™ 4 PROFESSIONAL-Edition - convenient unit and user management built on the BASIC edition. Suitable for networking up to 100 units.

APT-COM™ 4 GLP-Edition

For working under GLP-compliant conditions. Measured values are documented in a tamper-proof way in line with the requirements of FDA Regulation 21 CFR 11.. version 4, GLP edition

9053-0042

Multi Management Software APT-COM™

APT-COM™ 4 GLP-Edition - for working under GLP-compliant conditions. Measured values are documented in a tamper-proof way in line with the requirements of FDA Regulation 21 CFR 11.

pH-neutral detergent

Concentrated, for gentle remove of residual contaminants; 1 kg

8012-2250

1002-0016-Neutralreiniger-100x85_Web_670x515.jpg

pH-neutral detergent - concentrated, for gentle remove of residual contaminants; 1 kg

Qualification documents

IQ/OQ documents – supporting documents for validation performed by customers, consisting of: IQ/OQ checklists incl. calibration guide and comprehensive unit documentation; parameters: temperature, CO2, O2, pressure, depending on unit. Hard copy inside folder

7007-0001

Qualification documents

IQ/OQ documents – supporting documents for validation performed by customers, consisting of: IQ/OQ checklists incl. calibration guide and comprehensive unit documentation; parameters: temperature, CO2, O2, pressure, depending on unit. Digital in PDF format

7057-0001

Qualification documents

IQ/OQ/PQ documents – supporting documents for validation performed by customers, according to customer requirements, PQ section added to qualification folder IQ/OQ; parameters: temperature, CO2, O2 – or pressure, depending on unit. Hard copy inside folder

7007-0005

Qualification documents

IQ/OQ/PQ documents – supporting documents for validation performed by customers, according to customer requirements, PQ section added to qualification folder IQ/OQ; parameters: temperature, CO2, O2 – or pressure, depending on unit. Digital in PDF format

7057-0005

Sorry, no result could be found. Check the spelling or use a new search term.

Measurement of air exchange rate

In accordance with ASTM D5374, definition and protocol according to ambient temperature

8012-0195

Access port with silicone plug

Top. 30 mm

8012-0539

Access port with silicone plug

Access port with silicone plug - 30 mm, top

Access port with silicone plug

Back. 30 mm

8012-0540

Access port with silicone plug

Access port with silicone plug - 30 mm, back

Access port with silicone plug

Top. 50 mm

8012-0545

Access port with silicone plug

Access port with silicone plug - 50 mm, top

Access port with silicone plug

Back. 50 mm

8012-0546

Access port with silicone plug

Access port with silicone plug - 50 mm, back

Calibration certificate, expanded

For temperature; for extending the measurement in center of chamber to include another test temperature

8012-1115

Calibration certificate, temperature

For temperature, measurement in center of chamber at specified temperature

8012-1134

Access port with silicone plug

Top. 10 mm

8012-1262

Access port with silicone plug

Access port with silicone plug - 10 mm, top

Access port with silicone plug

Right. 10 mm

8012-1268

Access port with silicone plug

Access port with silicone plug - 10 mm, right

Access port with silicone plug

Left. 10 mm

8012-1275

Access port with silicone plug

Access port with silicone plug - 10 mm, left

Access port with silicone plug

Back. 10 mm

8012-1282

Access port with silicone plug

Access port with silicone plug - 10 mm, back

Calibration certificate, temperature

Temperature measurement incl. certificate, 9 measuring points at specified temperature

8012-1551

Calibration certificate, temperature

Temperature measurement incl. certificate, 15- 18 measuring points at specified temperature

8012-1572

Calibration certificate, temperature

Temperature measurement incl. certificate and 27 measuring points at specified temperature

8012-1593

Analog output 4-20 mA

For temperature values (output not adjustable)

8012-0430

Access port with silicone plug

Left. 30 mm

8012-0537

Access port with silicone plug

Access port with silicone plug - 30 mm, left

Access port with silicone plug

Right. 50 mm

8012-0541

Access port with silicone plug

Access port with silicone plug - 50 mm, right

Access port with silicone plug

Left. 50 mm

8012-0542

Access port with silicone plug

Access port with silicone plug - 50 mm, left

Pt 100 temperature sensor

Additional flexible Pt 100, interior, with external connection incl. LEMO connector (3-pin)

8012-1173

Pt 100 temperature sensor

Pt 100 temperature sensor - additional flexible Pt 100, interior, with external connection incl. LEMO connector (3-pin)

Access port with silicone plug

Right. 30 mm

8012-0536

Access port with silicone plug

Access port with silicone plug - 30 mm, right

Access port with silicone plug

Right. 100 mm

8012-0721

Access port with silicone plug

Access port with silicone plug - 100 mm, right

Access port with silicone plug

Left. 100 mm

8012-0722

Access port with silicone plug

Access port with silicone plug - 100 mm, left

Door lock

Lockable door handle

8012-1253

Door lock

Door lock - lockable door handle

Door gasket

Made of FKM, silicone-free

8012-0497

Door gasket

Door gasket - made of FKM, silicone-free  

Inner chamber, reinforced

Including 2 reinforced racks

8012-1730

Access port with silicone plug

Top. 100 mm

8012-0547

Access port with silicone plug

Access port with silicone plug - 100 mm, top

Class 3.1 independent temperature safety device

With visual alarm (DIN 12880)

8012-0032

Alarm function for overheating

Switchable acoustic alarm, with adjustable limit value on the independent temperature safety device. Not in combination with the following option: Door with window. 230/400 V option model

8012-1299

Viewing window and interior lighting

Viewing window 290 x 470 mm in every door and interior lighting 30 W. Not in combination with the following option: Alarm function for overheating. 400 V option model

8012-0269

Viewing window in the door

Viewing window and interior lighting - 400 V option model, Viewing window 290 x 470 mm in every door and interior lighting 30 W. Not in combination with the following option: Alarm function for overheating

Sorry, no result could be found. Check the spelling or use a new search term.

Calibration certificate, temperature

Extension of calibration of one (1) additional test temperature specified by the user in the center of the usable space, including certificate

DL30-0102

Services

Calibration certificate, temperature - Extension of calibration of one (1) additional test temperature specified by the user in the center of the usable space, including certificate

Temperature measurement, 9 measuring points

Temperature measurement with 9 measuring points with a set value specified by the user, including certificate

DL30-0109

Services

Temperature measurement, 9 measuring points - Temperature measurement with 9 measuring points with a set value specified by the user, including certificate

Temperature measurement, 18 measuring points

Temperature measurement with 18 measuring points with a set value specified by the user, including certificate

DL30-0118

Services

Temperature measurement, 18 measuring points - Temperature measurement with 18 measuring points with a set value specified by the user, including certificate

Temperature measurement, 27 measuring points

Temperature measurement with 27 measuring points with a set value specified by the user, including certificate

DL30-0127

Services

Temperature measurement, 27 measuring points - Temperature measurement with 27 measuring points with a set value specified by the user, including certificate

Execution of IQ/OQ/PQ

Execution of IQ/OQ/PQ in accordance with qualification folder

DL44-0500

Services

Execution of IQ/OQ/PQ - Execution of IQ/OQ/PQ in accordance with qualification folder

BRONZE 3-year maintenance contract

Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts

DL20-0720

Services

BRONZE 3-year maintenance contract - Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts

SILVER 3-year maintenance contract

Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts, testing of all key functions, calibration of one test temperature specified by the user in the center of the usable space, without certificate 

DL20-0815

Services

SILVER 3-year maintenance contract - Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts, testing of all key functions, calibration of one test temperature specified by the user in the center of the usable space, without certificate 

GOLD 3-year maintenance contract

Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts, testing of all key functions, replacement of wear parts, calibration of one test temperature specified by the user in the center of the usable space, including certificate

DL20-0915

Services

GOLD 3-year maintenance contract - Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts, testing of all key functions, replacement of wear parts, calibration of one test temperature specified by the user in the center of the usable space, including certificate

Unit commissioning

Connect the unit to the customer-side connections (electricity, water, wastewater, gas), basic functions check, brief operating instructions. (excl.: unpacking, setup, controller instructions, programming, installation work) 

DL10-0100

Services

Unit commissioning - Connect the unit to the customer-side connections (electricity, water, wastewater, gas), basic functions check, brief operating instructions. (excl.: unpacking, setup, controller instructions, programming, installation work) 

Unit instructions

Instruction regarding operating principle and basic functions of the unit, operation of the control electronics including programming

DL10-0500

Services

Unit instructions - Instruction regarding operating principle and basic functions of the unit, operation of the control electronics including programming

Maintenance

One-off maintenance service in accordance with maintenance schedule. Visual inspection of mechanical and electrical components, testing of all key functions. Calibration of a test temperature specified by the user in center of usable space without certificate

DL20-0601

Services

Maintenance - One-off maintenance service in accordance with maintenance schedule. Visual inspection of mechanical and electrical components, testing of all key functions. Calibration of a test temperature specified by the user in center of usable space without certificate

Calibration certificate, temperature

Calibration of one (1) test temperature specified by the user in center of chamber, including certificate

DL30-0110

Services

Calibration certificate, temperature - Calibration of one (1) test temperature specified by the user in center of chamber, including certificate

1-year warranty extension

The warranty is extended by 1 year from the delivery date, wear parts are excluded

DL50-0010

Services

1-year warranty extension - The warranty is extended by 1 year from the delivery date, wear parts are excluded

Execution of IQ/OQ

Execution of IQ/OQ in accordance with qualification folder

DL40-0100

Services

Execution of IQ/OQ - Execution of IQ/OQ in accordance with qualification folder

Measurement of air exchange rate

Including certificate (in accordance with ASTM D5374)

DL33-0000

Services

Measurement of air exchange rate - including certificate (in accordance with ASTM D5374)

Suggested products

Compare products:

Or add another product.