Model WIC 3 | Walk-in-chambers for stability testing according to ICH (Q1A)
Benefits
- Stable and uniform environment
- Fully complies with Pharma regulations (ICH)Equipment
- Longevity - corrosion resistant
- Ease of operation
- Environmental friendly refrigerant with GWP value 547
- Maintenance possible with the least possible disruption to the climate conditioning
- Perfectly meets requirements in Pharma industry
- 3 years warranty
Product description
The walk-in-chambers offer a wide range of features and benefits to perfectly meet requirements in stability testing. Perfect test conditions are maintained in a wide range of temperature from 10°C to 50°C and relative humidity of 20% to 90% RH.
Important characteristics
- Relative humidity accuracy of ± 2.5%
- Temperature accuracy of ± 1.5°C
- Duct work for proper distribution of air
- Highly insulated room panels with U value of only 0,21 W/m2K
- LED Lighting with motion detector
- High quality room elements, made in Germany
- Interior completely stainless steel
- Exterior service accessibility
- Room Elements: Galvanized sheet steel, polyester coated, white, similar to RAL 9010, interior surfaces in stainless steel,
4 inch / 100 mm PU foam U value: 0,21W/m2K - Floor: Floor overlay is chrome-nickel steel, pattern-rolled 5WL
- Surface load: 50.000 N/m2
Technical specifications
| Data | |
| Designation | WIC3-230V |
| Article Number | 9800-0013 |
| Option model | Standard |
| Performance Data Climate | |
| Temperature range with humidity | 10...50 °C |
| Humidity range | 20...90 % RH |
| Temperature uniformity at 25°C and 60% RH | 1.5 ± K |
| Temperature uniformity at 40°C and 75% RH | 1.5 ± K |
| Temperature fluctuation at 25°C and 60% RH | 0.5 ± K |
| Temperature fluctuation at 40°C and 75% RH | 0.5 ± K |
| Humidity fluctuation at 25°C and 60% RH | 2.5 ± % RH |
| Humidity fluctuation at 40°C and 75% RH | 2.5 ± % RH |
| Electrical data | |
| Rated Voltage | 230 V |
| Power frequency | 50 Hz |
| Nominal power | 2,7 kW |
| Unit fuse | 16,0 A |
| Phase (Nominal voltage) | 1~ |
| Dimensions and weights | |
| Interior volume | 24,516 L |
| Net weight of the unit (empty) | 1,186 kg |
| Housing dimensions not incl. fittings and connections | |
| Width net | 2,600 mm |
| Height net | 2,470 mm |
| Depth net | 4,700 mm |
| Internal Dimensions | |
| Interior width | 2,400 mm |
| Interior height | 2,270 mm |
| Interior depth | 4,500 mm |
| Unit doors | 1 |
| Environment-specific data | |
| Energy consumption at 40°C and 75% RH | 1,150 Wh/h |
Options, Accessories, Services
Sorry, no result could be found. Check the spelling or use a new search term.
Sorry, no result could be found. Check the spelling or use a new search term.
Installation and Comissioning - Installation and Comissioning
Access port with silicone plug - 1 access port with silicone plug, 30 mm - position of your choice
Access port with silicone plug - 2 access ports with silicone plugs, 30 mm - your choice of position
Access port with silicone plug - 3 access ports with silicone plugs, 30 mm - your choice of position
Access port with silicone plug - 4 access ports with silicone plugs, 30 mm - your choice of position
Access port with silicone plug - 5 access ports with silicone plugs, 30 mm - your choice of position
Access port with silicone plug - 1 access port with silicone plug, 50 mm - your choice of position
Access port with silicone plug - 2 access ports with silicone plugs, 50 mm - your choice of position
Access port with silicone plug - 3 access ports with silicone plugs, 50 mm - your choice of position
Access port with silicone plug - 4 access ports with silicone plugs, 50 mm - your choice of position
Access port with silicone plug - 5 access ports with silicone plugs, 50 mm - your choice of position
Maintenance - One-off maintenance service in accordance with maintenance schedule. Visual inspection of mechanical and electrical components, testing of all key functions. Calibration of a test temperature specified by the user in center of usable space without certificate
Temperature and humidity measurement, 13-1 measuring points - Temperature measurement with 13 temperature measuring points and 1 humidity measuring point in center of chamber with a pair of values specified by the user, including certificate
Extension of temperature and humidity measurement 13-1 measuring points - Calibration of an additional climate point specified by the user, including certificate.
Execution of IQ/OQ - Execution of IQ/OQ in accordance with qualification folder