Model 170
Model 170
Dimensions
Accessories: Shaker Professional and Universal
Accessories: stacking frame, stacking adapter, base frame
Product image
Product image
Product image
Product image
Product image

Model CB-S 170 | CO2 incubators with hot air sterilization

Benefits
  • Safe – cell cultures receive maximum protection against contamination
  • Reliable – constant well-being conditions for the cells
  • Smart – simple routine cleaning and convenient operation
  • Economical – efficient operation without consumables

Configure your product with options and accessories and request it directly here.

Product description

The durable and affordable CB-S series incubators are suitable for routine cell cultivation applications in the field of cell production, particularly in academic settings. They are contamination-proof due to 180°C hot air sterilization and reliably pH-stable thanks to the drift-free infrared CO₂ measurements conducted in real time.

Important characteristics

  • Temperature range: +6°C above ambient temperature to +50°C
  • Humidity range: 90 to 95% RH
  • CO₂ control range: 0 to 20 vol.% CO₂
  • Tried-and-tested anti-contamination concept with 180°C hot air sterilization
  • Humidification system with condensation protection
  • CO2 gas mixing jet with Venturi effect
  • CO2 sensor with infrared technology
  • LCD to display temperature and CO2 along with additional information and alarms
  • Internal data logger, measured values can be read out in open format via USB
  • Tightly fitted inner door made of safety glass
  • Seamless stainless steel inner chamber
  • Perforated shelves, stainless steel
  • Troubleshooting system with visual and acoustic alarms
  • Interfaces: Ethernet, USB, zero-voltage alarm contact
  • Units can be stacked with stacking adapters; the CB-S is suitable for stacking with CB and CBF models of the same size

Technical specifications

Data
Designation

CBS170-230V

CBS170-230V-D

CBS170UL-120V

CBS170UL-120V-D

Article Number9640-00019640-00299640-00029640-0030
Option modelStandard

with Access port 30 mm left

Standard

with Access port 30 mm left

Performance Data Temperature
Temperature range+6 °C above ambient temperature to 50 °C+6 °C above ambient temperature to 50 °C+6 °C above ambient temperature to 50 °C+6 °C above ambient temperature to 50 °C
Temperature uniformity at 37°C0.3 ± K0.3 ± K0.3 ± K0.3 ± K
Temperature fluctuation at 37°C0.1 ± K0.1 ± K0.1 ± K0.1 ± K
Recovery time after door was opened for 30 s at 37°C6 min6 min6 min6 min
Performance Data Climate
Humidity range90 ...95 % RH90 ...95 % RH90 ...95 % RH90 ...95 % RH
Gas Data
CO₂ range0 ...20 Vol.-% CO₂0 ...20 Vol.-% CO₂0 ...20 Vol.-% CO₂0 ...20 Vol.-% CO₂
CO₂ measuring technologyIRIRIRIR
CO₂ recovery time after door was opened for 30 s at 5 vol. % CO₂5 min5 min5 min5 min
Electrical data
Rated Voltage200...230 V200...230 V100...120 V100...120 V
Power frequency50/60 Hz50/60 Hz50/60 Hz50/60 Hz
Nominal power1,3 kW1,3 kW1,3 kW1,3 kW
Unit fuse10,0 A10,0 A16,0 A16,0 A
Phase (Nominal voltage)1~1~1~1~
Dimensions and weights
Interior volume170 L170 L170 L170 L
Net weight of the unit (empty)96 kg96 kg96 kg96 kg
Load per rack10 kg10 kg10 kg10 kg
Permitted load30 kg30 kg30 kg30 kg
Wall clearance back100 mm100 mm100 mm100 mm
Wall clearance sidewise50 mm50 mm50 mm50 mm
Housing dimensions not incl. fittings and connections
Width net680 mm680 mm680 mm680 mm
Height net870 mm870 mm870 mm870 mm
Depth net715 mm715 mm715 mm715 mm
Internal Dimensions
Interior width560 mm560 mm560 mm560 mm
Interior height600 mm600 mm600 mm600 mm
Interior depth505 mm505 mm505 mm505 mm
Inner doors1111
Unit doors1111
Environment-specific data
Sound-pressure level41 dB(A)41 dB(A)41 dB(A)41 dB(A)
Energy consumption at 37°C45 Wh/h45 Wh/h45 Wh/h45 Wh/h
Fixtures
Number of shelves (std./max.)2/62/62/62/6

Downloads

CO2 incubators

CB-S | CB | CBF series

pdf, 872.55 KB

Stacking options for BINDER CO2 incubators

CB-S | CB series

pdf, 161.65 KB

CO₂ incubator (CB series) - Stem cell research into healing musculoskeletal disorders

University of Rochester School of Medicine and Dentistry

pdf, 224.21 KB

CB-S series

pdf, 8.69 MB

Binder Gas Supply Service

Mounting and Operating Instructions

pdf, 7.67 MB

Data Sheet Model CB-S 170

pdf, 466.29 KB

Options, Accessories, Services

Sorry, no result could be found. Check the spelling or use a new search term.

Calibration certificate, temperature and CO2

For temperature and CO2, temperature measurement in center of chamber, CO2 measurement performed using test gas at 37 °C and 5 % CO2

8012-0228

Access port with silicone plug

Right. 30 mm

8612-0019

Access port with silicone plug

Access port with silicone plug - 30 mm, right

Door hinged on the left

Unit door and standard glass inner door with door hinged on the left

8612-0020

Door lock

Lockable door handle

8612-0021

8012-1014-Abschließbarer-Tuergriff-100x85_Web_670x515.jpg

Door lock - lockable door handle

Calibration certificate, expanded

For temperature; for extending the measurement in center of chamber to include another test temperature

8012-1112

Calibration certificate, temperature

For temperature, measurement in center of chamber at specified temperature

8012-1131

Calibration certificate, temperature

Temperature measurement incl. certificate, 9 measuring points at specified temperature

8012-1549

Calibration certificate, temperature

Temperature measurement incl. certificate, 15- 18 measuring points at specified temperature

8012-1570

Calibration certificate, temperature

Temperature measurement incl. certificate and 27 measuring points at specified temperature

8012-1591

Analog output 4-20 mA

For temperature and CO2 values (outputs not adjustable)

8612-0016

Access port with silicone plug

Back. 30 mm

8612-0017

Access port with silicone plug

Access port with silicone plug - 30 mm, back

Access port with silicone plug

Left. 30 mm

8612-0018

Access port with silicone plug

Access port with silicone plug - 30 mm, left

Sorry, no result could be found. Check the spelling or use a new search term.

BRONZE 3-year maintenance contract

Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts

DL20-0710

Services

BRONZE 3-year maintenance contract - Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts

SILVER 3-year maintenance contract

Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts, testing of all key functions, calibration of one test temperature specified by the user in the center of the usable space, without certificate 

DL20-0875

Services

SILVER 3-year maintenance contract - Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts, testing of all key functions, calibration of one test temperature specified by the user in the center of the usable space, without certificate 

GOLD 3-year maintenance contract

Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts, testing of all key functions, replacement of wear parts, calibration of one test temperature specified by the user in the center of the usable space, including certificate

DL20-0975

Services

GOLD 3-year maintenance contract - Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts, testing of all key functions, replacement of wear parts, calibration of one test temperature specified by the user in the center of the usable space, including certificate

Unit commissioning

Connect the unit to the customer-side connections (electricity, water, wastewater, gas), basic functions check, brief operating instructions. (excl.: unpacking, setup, controller instructions, programming, installation work) 

DL10-0110

Services

Unit commissioning - Connect the unit to the customer-side connections (electricity, water, wastewater, gas), basic functions check, brief operating instructions. (excl.: unpacking, setup, controller instructions, programming, installation work) 

Unit instructions

Instruction regarding operating principle and basic functions of the unit, operation of the control electronics including programming

DL10-0510

Services

Unit instructions - Instruction regarding operating principle and basic functions of the unit, operation of the control electronics including programming

Maintenance

One-off maintenance service in accordance with maintenance schedule. Visual inspection of mechanical and electrical components, testing of all key functions. Calibration of a test temperature specified by the user in center of usable space without certificate

DL20-0608

Services

Maintenance - One-off maintenance service in accordance with maintenance schedule. Visual inspection of mechanical and electrical components, testing of all key functions. Calibration of a test temperature specified by the user in center of usable space without certificate

CO₂ calibration

CO₂ calibration at a specified value, measurements are taken with analyzed test gas at 5%, including certificate

DL30-0401

Services

Calibration CO2 - including certificate, CO2 measurement with analyzed test gas at 5 % or at specified value

Calibration certificate, temperature

Calibration of one (1) test temperature specified by the user in center of chamber, including certificate

DL30-0140

Services

Calibration certificate, temperature - Calibration of one (1) test temperature specified by the user in center of chamber, including certificate

Calibration certificate, temperature

Extension of calibration of one (1) additional test temperature specified by the user in the center of the usable space, including certificate

DL30-0102

Services

Calibration certificate, temperature - Extension of calibration of one (1) additional test temperature specified by the user in the center of the usable space, including certificate

Temperature measurement, 9 measuring points

Temperature measurement with 9 measuring points with a set value specified by the user, including certificate

DL30-0109

Services

Temperature measurement, 9 measuring points - Temperature measurement with 9 measuring points with a set value specified by the user, including certificate

Temperature measurement, 18 measuring points

Temperature measurement with 18 measuring points with a set value specified by the user, including certificate

DL30-0118

Services

Temperature measurement, 18 measuring points - Temperature measurement with 18 measuring points with a set value specified by the user, including certificate

Temperature measurement, 27 measuring points

Temperature measurement with 27 measuring points with a set value specified by the user, including certificate

DL30-0127

Services

Temperature measurement, 27 measuring points - Temperature measurement with 27 measuring points with a set value specified by the user, including certificate

Execution of IQ/OQ

Execution of IQ/OQ in accordance with qualification folder

DL41-0200

Services

Execution of IQ/OQ - Execution of IQ/OQ in accordance with qualification folder

Execution of IQ/OQ/PQ

Execution of IQ/OQ/PQ in accordance with qualification folder

DL44-0500

Services

Execution of IQ/OQ/PQ - Execution of IQ/OQ/PQ in accordance with qualification folder

1-year warranty extension

The warranty is extended by 1 year from the delivery date, wear parts are excluded

DL50-0020

Services

1-year warranty extension - The warranty is extended by 1 year from the delivery date, wear parts are excluded

Sorry, no result could be found. Check the spelling or use a new search term.

Copper interior fittings

Set consisting of 2 shelves (all-copper) and a water pan (copper-plated)

8012-1997

Copper interior fittings

Copper interior fittings - Set consisting of 2 shelves (all-copper) and a water pan (copper-plated)

Base

The base equipped with casters is used for the secure positioning and leveling of a BINDER CO2 incubator

9051-0028

9051-0028-Untergestell-100-85_Web_670x515.jpg

Base - the base equipped with casters is used for the secure positioning and leveling of a BINDER CO2 incubator

Stacking adapter

For the thermally isolated stacking of two BINDER CO2 incubators

9051-0035

9051-0040-Stapelgestell-CB170-E7-mit-Rollen_Web_670x515.jpg

Stacking adapter - for the thermally isolated stacking of two BINDER CO2 incubators

Stacking frame

Stable, vibration-free stacking frame on casters with stop brake for safe stacking of two CB series units

9051-0040

Stacking variants

Stacking frame - stable, vibration-free stacking frame on casters with stop brake for safe stacking of two CB series units

Shelf, perforated

Stainless steel

8012-2167

Shelf

Shelf, perforated - Stainless steel

APT-COM™ 4 BASIC-Edition

For simple logging and documentation requirements with up to 5 networked units.. version 4, BASIC edition 

9053-0039

Multi Management Software APT-COM™

APT-COM™ 4 BASIC-Edition - for simple logging and documentation requirements with up to 5 networked units.

APT-COM™ 4 PROFESSIONAL-Edition

Convenient unit and user management built on the BASIC edition. Suitable for networking up to 100 units.. version 4, PROFESSIONAL edition

9053-0040

Multi Management Software APT-COM™

APT-COM™ 4 PROFESSIONAL-Edition - convenient unit and user management built on the BASIC edition. Suitable for networking up to 100 units.

APT-COM™ 4 GLP-Edition

For working under GLP-compliant conditions. Measured values are documented in a tamper-proof way in line with the requirements of FDA Regulation 21 CFR 11.. version 4, GLP edition

9053-0042

Multi Management Software APT-COM™

APT-COM™ 4 GLP-Edition - for working under GLP-compliant conditions. Measured values are documented in a tamper-proof way in line with the requirements of FDA Regulation 21 CFR 11.

pH-neutral detergent

Concentrated, for gentle remove of residual contaminants; 1 kg

8012-2250

1002-0016-Neutralreiniger-100x85_Web_670x515.jpg

pH-neutral detergent - concentrated, for gentle remove of residual contaminants; 1 kg

Cleaning kit

For equipment maintenance and disinfection, consisting of pH-neutral detergent (1000 g, concentrate), spray disinfectant (500 ml, ready-to-use solution), lint-free cleansing tissues, protective gloves, and protective glasses

8012-0503

Gas cylinder connection set

For CO₂, consisting of a gas tank pressure regulator with connection parts and 5-meter hose

8012-0014

Qualification documents

IQ/OQ documents – supporting documents for validation performed by customers, consisting of: IQ/OQ checklists incl. calibration guide and comprehensive unit documentation; parameters: temperature, CO2, O2, pressure, depending on unit. Hard copy inside folder

7007-0001

Qualification documents

IQ/OQ documents – supporting documents for validation performed by customers, consisting of: IQ/OQ checklists incl. calibration guide and comprehensive unit documentation; parameters: temperature, CO2, O2, pressure, depending on unit. Digital in PDF format

7057-0001

Qualification documents

IQ/OQ/PQ documents – supporting documents for validation performed by customers, according to customer requirements, PQ section added to qualification folder IQ/OQ; parameters: temperature, CO2, O2 – or pressure, depending on unit. Hard copy inside folder

7007-0005

Qualification documents

IQ/OQ/PQ documents – supporting documents for validation performed by customers, according to customer requirements, PQ section added to qualification folder IQ/OQ; parameters: temperature, CO2, O2 – or pressure, depending on unit. Digital in PDF format

7057-0005

Shaker „Universal“

Shaker and controller connected via ribbon cable, universally applicable, 100 – 240 V, 50/60 Hz

8012-1771

BINDER CO2 - shakers

Shaker „Universal“ - Shaker and controller connected via ribbon cable, universally applicable, 100 – 240 V, 50/60 Hz

Gas tank changer

External, BINDER Gas Supply Service, for connecting 2 gas tanks (CO2, N2 or O2), with audible and visual alarms, as well as zero-voltage alarm output

8012-2344

CO2 gas tank changer

Gas tank changer - external, BINDER Gas Supply Service, for connecting 2 gas tanks (CO2, N2 or O2), with audible and visual alarms, as well as zero-voltage alarm output

Rubber pads

Set anti-slip feet

8012-0702

Water supply

Set consisting of 6 bottles, each with 1,000 ml of sterile humidification water

8009-1192

Compare products:

Or add another product.