Model CB 56 | CO2 incubators with hot air sterilization and heat sterilizable CO2 sensor
Benefits
- Sicher durch maximalem Kontaminationsschutz der Zellkulturen
- Zuverlässig durch konstante Wohlfühl-Bedingungen für die Zellen
- Smart durch einfache Routinereinigung und bequeme Bedienung
- TEST - Wirtschaftlich durch sparsamen Betrieb ohne Verbrauchsmaterial
Product description
The powerful and versatile CB CO₂ incubator is suitable for cell-based assays in drug and medical research. This BINDER incubator is even suitable for complex cultivation experiments or individual environments with hypoxic conditions thanks to its comprehensive assortment of options and accessories.
Important characteristics
- Optimiertes Befeuchtungssystem mit Betauungsschutz
- Bewährtes Antikontaminationskonzept mit 180 °C Heißluftsterilisation
- Heißluftsterilisierbarer CO₂-Sensor mit Einstrahl-Infrarot-Technologie
- Nahtloser Innenkessel aus Edelstahl mit Sicken als Einschubträger
- Lüfterloser Innenraum mit Venturi-CO₂-Gasmischdüse
- Intuitiv bedienbarer Touchscreen-Controller
- Interner Datenlogger, Messwerte im offenen Format über USB auslesbar
- Fehlerdiagnosesystem mit optischem und akustischem Alarm
- Schnittstellen: Ethernet, USB, Potenzialfreier Alarmkontakt
- CO₂ Fail Safe System zum pH-Schutz der Zellkulturen
- Test
Technical specifications
| Data | ||
| Designation | CB056-230V | CB056UL-120V |
| Article Number | 9040-0197 | 9040-0198 |
| Option model | Standard | Standard |
| Performance Data Temperature | ||
| Temperature range | +4 °C above ambient temperature to 50 °C | +4 °C above ambient temperature to 50 °C |
| Temperature uniformity at 37°C | 0.3 ± K | 0.3 ± K |
| Temperature fluctuation at 37°C | 0.1 ± K | 0.1 ± K |
| Recovery time after door was opened for 30 s at 37°C | 5 min | 5 min |
| Performance Data Climate | ||
| Humidity range | 90 ...95 % RH | 90 ...95 % RH |
| Gas Data | ||
| CO₂ range | 0 ...20 Vol.-% CO₂ | 0 ...20 Vol.-% CO₂ |
| CO₂ measuring technology | IR | IR |
| CO₂ recovery time after door was opened for 30 s at 5 vol. % CO₂ | 5 min | 5 min |
| Electrical data | ||
| Rated Voltage | 200...230 V | 100...120 V |
| Power frequency | 50/60 Hz | 50/60 Hz |
| Nominal power | 0,8 kW | 0,8 kW |
| Unit fuse | 10,0 A | 16,0 A |
| Phase (Nominal voltage) | 1~ | 1~ |
| Dimensions and weights | ||
| Interior volume | 53 L | 53 L |
| Net weight of the unit (empty) | 53 kg | 53 kg |
| Load per rack | 10 kg | 10 kg |
| Permitted load | 30 kg | 30 kg |
| Wall clearance back | 100 mm | 100 mm |
| Wall clearance sidewise | 50 mm | 50 mm |
| Housing dimensions not incl. fittings and connections | ||
| Width net | 528 mm | 528 mm |
| Height net | 674 mm | 674 mm |
| Depth net | 545 mm | 545 mm |
| Internal Dimensions | ||
| Interior width | 400 mm | 400 mm |
| Interior height | 400 mm | 400 mm |
| Interior depth | 330 mm | 330 mm |
| Inner doors | 1 | 1 |
| Unit doors | 1 | 1 |
| Environment-specific data | ||
| Sound-pressure level | 41 dB(A) | 41 dB(A) |
| Energy consumption at 37°C | 45 Wh/h | 45 Wh/h |
| Fixtures | ||
| Number of shelves (std./max.) | 2/3 | 2/3 |
Options, accessories & services
Sorry, no result could be found. Check the spelling or use a new search term.
Inner door, divided - Cell therapy compartmentalization, consisting of 4 inner doors and two shelf levels with one partition wall each
Access port with silicone plug - 30 mm, back
Access port with silicone plug - 30 mm, left
Access port with silicone plug - 30 mm, right
Sorry, no result could be found. Check the spelling or use a new search term.
BRONZE 3-year maintenance contract - Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts
SILVER 3-year maintenance contract - Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts, testing of all key functions, calibration of one test temperature specified by the user in the center of the usable space, without certificate
GOLD 3-year maintenance contract - Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts, testing of all key functions, replacement of wear parts, calibration of one test temperature specified by the user in the center of the usable space, including certificate
Maintenance - One-off maintenance service in accordance with maintenance schedule. Visual inspection of mechanical and electrical components, testing of all key functions. Calibration of a test temperature specified by the user in center of usable space without certificate
Calibration CO2 - including certificate, CO2 measurement with analyzed test gas at 5 % or at specified value
Calibration certificate, temperature - Calibration of one (1) test temperature specified by the user in center of chamber, including certificate
Calibration certificate, temperature - Extension of calibration of one (1) additional test temperature specified by the user in the center of the usable space, including certificate
Temperature measurement, 9 measuring points - Temperature measurement with 9 measuring points with a set value specified by the user, including certificate
Temperature measurement, 18 measuring points - Temperature measurement with 18 measuring points with a set value specified by the user, including certificate
Temperature measurement, 27 measuring points - Temperature measurement with 27 measuring points with a set value specified by the user, including certificate
Execution of IQ/OQ - Execution of IQ/OQ in accordance with qualification folder
Execution of IQ/OQ/PQ - Execution of IQ/OQ/PQ in accordance with qualification folder
1-year warranty extension - The warranty is extended by 1 year from the delivery date, wear parts are excluded
Unit commissioning - Connect the unit to the customer-side connections (electricity, water, wastewater, gas), basic functions check, brief operating instructions. (excl.: unpacking, setup, controller instructions, programming, installation work)
Unit instructions - Instruction regarding operating principle and basic functions of the unit, operation of the control electronics including programming
Sorry, no result could be found. Check the spelling or use a new search term.
Stacking adapter - for the thermally isolated stacking of two BINDER CO2 incubators
Base - the base equipped with casters is used for the secure positioning and leveling of a BINDER CO2 incubator
APT-COM™ 4 BASIC-Edition - for simple logging and documentation requirements with up to 5 networked units.
APT-COM™ 4 PROFESSIONAL-Edition - convenient unit and user management built on the BASIC edition. Suitable for networking up to 100 units.
APT-COM™ 4 GLP-Edition - for working under GLP-compliant conditions. Measured values are documented in a tamper-proof way in line with the requirements of FDA Regulation 21 CFR 11.
Shelf, perforated - stainless steel, for divided inner door
Shelf, perforated - Stainless steel
pH-neutral detergent - concentrated, for gentle remove of residual contaminants; 1 kg
Gas tank changer - external, BINDER Gas Supply Service, for connecting 2 gas tanks (CO2, N2 or O2), with audible and visual alarms, as well as zero-voltage alarm output