Model 1
Model 1
Model 1
Model 1
Dimensions
Climate chart
Product image
Product image
Product image
Product image
Product image
Product image
Product image
Product image
Product image

Model WIC 1 | Walk-in-chambers for Stability Testing and Storage

Benefits
  • Stable and uniform environment
  • Fully complies with Pharma regulations (ICH)Equipment
  • Longevity - corrosion resistant
  • Ease of operation
  • Environmental friendly refrigerant with GWP value 547
  • Maintenance possible with the least possible disruption to the climate conditioning
  • Perfectly meets requirements in Pharma industry
  • 3 years warranty

Configure your product with options and accessories and request it directly here.

Product description

The walk-in-chambers offer a wide range of features and benefits to perfectly meet requirements in stability testing. Perfect test conditions are maintained in a wide range of temperature from 10°C to 50°C and relative humidity of 20% to 90% RH.

Important characteristics

  • Relative humidity accuracy of ± 2.5%
  • Temperature accuracy of ± 1.5°C
  • Duct work for proper distribution of air
  • Highly insulated room panels with U value of only 0,21 W/m2K
  • LED Lighting with motion detector
  • High quality room elements, made in Germany
  • Interior completely stainless steel
  • Exterior service accessibility
  • Room Elements: Galvanized sheet steel, polyester coated, white, similar to RAL 9010, interior surfaces in stainless steel,
    4 inch / 100 mm PU foam U value: 0,21W/m2K
  • Floor: Floor overlay is chrome-nickel steel, pattern-rolled 5WL
  • Surface load: 50.000 N/m2

Technical specifications

Data
Designation

WIC1-230V

WIC1-208V

WIC1C-208V

Article Number9800-00119800-00019800-0002
Option model

Standard

Standard

with conditioner on ceiling

Performance Data Climate
Temperature range with humidity10...50 °C10...50 °C10...50 °C
Temperature uniformity at 25°C and 60% RH1.5 ± K1.5 ± K1.5 ± K
Temperature uniformity at 40°C and 75% RH1.5 ± K1.5 ± K1.5 ± K
Temperature fluctuation at 25°C and 60% RH0.5 ± K0.5 ± K0.5 ± K
Temperature fluctuation at 40°C and 75% RH0.5 ± K0.5 ± K0.5 ± K
Electrical data
Rated Voltage200...230 V208...230 V208...230 V
Power frequency50 Hz60 Hz60 Hz
Nominal power2,7 kW2,7 kW2,7 kW
Unit fuse20,0 A20,0 A20,0 A
Phase (Nominal voltage)1~1~1~
Measures
Net weight of the unit (empty)776 kg776 kg776 kg
Internal Dimensions
Interior width2400 mm2400 mm2400 mm
Interior height2270 mm2270 mm2270 mm
Interior depth2300 mm2300 mm2300 mm
Environment-specific data
Energy consumption at 40°C and 75% RH1,130 Wh/h1,130 Wh/h1,130 Wh/h

Downloads

Walk-in-chamber Brochure

pdf, 243.73 KB

Suggested products

WIC 2

Model WIC 2 | Walk-in-chambers for Stability Testing and Storage

  • Relative humidity accuracy of ± 2.5%
  • Temperature accuracy of ± 1.5°C
  • LED Lighting with motion detector
  • Interior completely stainless steel
To product
WIC 3

Model WIC 3 | Walk-in-chambers for Stability Testing and Storage

  • Relative humidity accuracy of ± 2.5%
  • Temperature accuracy of ± 1.5°C
  • LED Lighting with motion detector
  • Interior completely stainless steel
To product

Compare products: