Model FDL 115 | Safety drying chambers for limited quantities of solvent
Benefits
- Safety concept meets the DIN EN 1539-2010-08 standard
- Short drying time with high temperature accuracy and defined ventilation
- Silicone free and dust-free inner chamber
- Replaceable fresh air cartridges are easy to change and ensure constant fresh air quality
Product description
The BINDER FDL 115 with silicone and dust-free inner chamber, as well as symmetric airflow dries specimens containing solvents and thus this safety drying oven meets all EN 1539 requirements.
Important characteristics
- Temperature range: +10°C above ambient temperature to +300 °C
- APT.line™ preheating chamber technology
- Controller with time-segment and real-time programming
- 2 chrome-plated racks
- Fresh-air monitoring with audible and visual alarm and automatic deactivation of heating
- Replaceable filter cartridge, Class M6
- Class 2 independent adjustable temperature safety device (DIN 12880) with visual alarm
- Computer interface: RS 422
- Standard door gasket made from solvent-resistant FKM for use at up to 200 °C
- Optional door gasket made from silicone with limited solvent resistance for use at up to 300 °C
Technical specifications
| Data | |
| Designation | FDL115-230V |
| Article Number | 9010-0292 |
| Option model | Standard |
| Performance Data Temperature | |
| Temperature range | +10 °C above ambient temperature to 300 °C |
| Temperature uniformity at 150°C | 2.5 ± K |
| Temperature fluctuation at 150°C | 0.8 ± K |
| Heating up time to 150°C | 20 min |
| Recovery time after door was opened for 30 s at 150°C | 12 min |
| Air change data | |
| Air circulation (approx.) | 20 x/min |
| Volumetric flow rate of exhaust air acc. to EN 1539 at 50 °C | 400 ca. L/min |
| Solvent quantity | |
| Highest permitted solvent quantity (at T-180°C, M-100g/mol, U-40g/m3, K=0,5) | 4,67 g |
| Electrical data | |
| Rated Voltage | 230 V |
| Power frequency | 50/60 Hz |
| Nominal power | 2,9 kW |
| Phase (Nominal voltage) | 1~ |
| Dimensions and weights | |
| Interior volume | 115 L |
| Net weight of the unit (empty) | 90 kg |
| Load per rack | 30 kg |
| Permitted load | 60 kg |
| Wall clearance back | 160 mm |
| Wall clearance sidewise | 100 mm |
| Housing dimensions not incl. fittings and connections | |
| Width net | 830 mm |
| Height net | 805 mm |
| Depth net | 685 mm |
| Internal Dimensions | |
| Interior width | 600 mm |
| Interior height | 435 mm |
| Interior depth | 435 mm |
| Unit doors | 1 |
| Environment-specific data | |
| Sound-pressure level | 57 dB(A) |
| Energy consumption at 150°C | 1,200 Wh/h |
| Fixtures | |
| Number of shelves (std./max.) | 2/5 |
Downloads
Options, Accessories, Services
Sorry, no result could be found. Check the spelling or use a new search term.
stable cart, casters with locking brakes, dimensions: W 1,000 x D 800 x H 780 mm
Rack - stainless steel
Shelf, perforated - Stainless steel
pH-neutral detergent - concentrated, for gentle remove of residual contaminants; 1 kg
APT-COM™ 4 BASIC-Edition - for simple logging and documentation requirements with up to 5 networked units.
APT-COM™ 4 PROFESSIONAL-Edition - convenient unit and user management built on the BASIC edition. Suitable for networking up to 100 units.
APT-COM™ 4 GLP-Edition - for working under GLP-compliant conditions. Measured values are documented in a tamper-proof way in line with the requirements of FDA Regulation 21 CFR 11.
Sorry, no result could be found. Check the spelling or use a new search term.
Sorry, no result could be found. Check the spelling or use a new search term.
Temperature measurement, 9 measuring points - Temperature measurement with 9 measuring points with a set value specified by the user, including certificate
Temperature measurement, 18 measuring points - Temperature measurement with 18 measuring points with a set value specified by the user, including certificate
Temperature measurement, 27 measuring points - Temperature measurement with 27 measuring points with a set value specified by the user, including certificate
Measurement of air exchange rate - including certificate (in accordance with ASTM D5374)
Execution of IQ/OQ - Execution of IQ/OQ in accordance with qualification folder
Execution of IQ/OQ/PQ - Execution of IQ/OQ/PQ in accordance with qualification folder
Calibration certificate, temperature - Extension of calibration of one (1) additional test temperature specified by the user in the center of the usable space, including certificate
1-year warranty extension - The warranty is extended by 1 year from the delivery date, wear parts are excluded
SILVER 3-year maintenance contract - Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts, testing of all key functions, calibration of one test temperature specified by the user in the center of the usable space, without certificate
BRONZE 3-year maintenance contract - Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts
Maintenance - One-off maintenance service in accordance with maintenance schedule. Visual inspection of mechanical and electrical components, testing of all key functions. Calibration of a test temperature specified by the user in center of usable space without certificate
Calibration certificate, temperature - Calibration of one (1) test temperature specified by the user in center of chamber, including certificate