Model FED 400 | Drying and heating chambers with forced convection and enhanced timer functions
Benefits
- Uniform drying conditions thanks to APT.line™ technology
- Identical test conditions throughout the chamber interior independent of sample size and quantity
- Outstanding thermal insulation saves operation costs
Product description
BINDER heating chambers of the FED series provide almost unlimited capacity and are particularly adaptable. With advanced timing functions and a adjustable fan, temperature and convection conditions are easily controlled.
Important characteristics
- Temperature range: +5°C above ambient temperature to +300 °C
- APT.line™ preheating chamber technology
- Adjustable fan speed
- Adjustable exhaust air flap
- Controller with expanded timer functions
- 2 chrome-plated racks
- Class 2 independent adjustable temperature safety device (DIN 12880) with visual alarm
- Computer interface: RS 422
Technical specifications
| Data | ||
| Designation | FED400-400V | FED400UL-208V |
| Article Number | 9010-0216 | 9010-0217 |
| Option model | Standard | Standard |
| Performance Data Temperature | ||
| Temperature range | +5 °C above ambient temperature to 300 °C | +5 °C above ambient temperature to 300 °C |
| Temperature uniformity at 150°C | 3.8 ± K | 3.8 ± K |
| Temperature fluctuation at 150°C | 0.7 ± K | 0.7 ± K |
| Heating up time to 150°C | 29 min | 29 min |
| Recovery time after door was opened for 30 s at 150°C | 6 min | 6 min |
| Air change data | ||
| Air change rate at 150°C | 18 x/h | 18 x/h |
| Electrical data | ||
| Rated Voltage | 400 V | 208 V |
| Power frequency | 50/60 Hz | 60 Hz |
| Nominal power | 3,4 kW | 3,4 kW |
| Unit fuse | 16,0 A | 16,0 A |
| Phase (Nominal voltage) | 3~/N/PE | 3~ |
| Dimensions and weights | ||
| Interior volume | 400 L | 400 L |
| Net weight of the unit (empty) | 145 kg | 145 kg |
| Load per rack | 35 kg | 35 kg |
| Permitted load | 90 kg | 90 kg |
| Wall clearance back | 160 mm | 160 mm |
| Wall clearance sidewise | 100 mm | 100 mm |
| Housing dimensions not incl. fittings and connections | ||
| Width net | 1,235 mm | 1,235 mm |
| Height net | 1,025 mm | 1,025 mm |
| Depth net | 765 mm | 765 mm |
| Internal Dimensions | ||
| Interior width | 1,000 mm | 1,000 mm |
| Interior height | 800 mm | 800 mm |
| Interior depth | 510 mm | 510 mm |
| Unit doors | 2 | 2 |
| Environment-specific data | ||
| Energy consumption at 150°C | 1,200 Wh/h | 1,200 Wh/h |
| Fixtures | ||
| Number of shelves (std./max.) | 2/10 | 2/10 |
Downloads
Options, Accessories, Services
Sorry, no result could be found. Check the spelling or use a new search term.
Rack - chrome plated
Rack - stainless steel
Shelf, perforated - Stainless steel
Rack accessories - fasteners (1 set of 4) for additional security of racks
Rack, reinforced - stainless steel, with fasteners (1 set of 4)
APT-COM™ 4 BASIC-Edition - for simple logging and documentation requirements with up to 5 networked units.
APT-COM™ 4 PROFESSIONAL-Edition - convenient unit and user management built on the BASIC edition. Suitable for networking up to 100 units.
APT-COM™ 4 GLP-Edition - for working under GLP-compliant conditions. Measured values are documented in a tamper-proof way in line with the requirements of FDA Regulation 21 CFR 11.
pH-neutral detergent - concentrated, for gentle remove of residual contaminants; 1 kg
Sorry, no result could be found. Check the spelling or use a new search term.
Access port with silicone plug - 10 mm, right
Access port with silicone plug - 10 mm, left
Access port with silicone plug - 30 mm, top
Access port with silicone plug - 50 mm, top
Access port with silicone plug - 10 mm, top
Door gasket - made of FKM, silicone-free
HEPA air filter - On fresh air supply for unit; filter classification H14 (acc. to. EN 1822-1:2009, > 99.995% at 0.3 µm); not in conjunction with reinforced heating output, reinforced fan
Pt 100 temperature sensor - additional flexible Pt 100, interior, with external connection incl. LEMO connector (3-pin)
Door lock - lockable door handle
Access port with silicone plug - 10 mm, back
Access port with silicone plug - 30 mm, right
Access port with silicone plug - 30 mm, left
Access port with silicone plug - 50 mm, right
Access port with silicone plug - 50 mm, left
Access port with silicone plug - 50 mm, back
Access port with silicone plug - 100 mm, top
Access port with silicone plug - 100 mm, left
Access port with silicone plug - 30 mm, back
Access port with silicone plug - 100 mm, right
Viewing window and interior lighting - 400 V option model, Viewing window 290 x 470 mm in every door and interior lighting 30 W. Not in combination with the following option: Alarm function for overheating
Sorry, no result could be found. Check the spelling or use a new search term.
Calibration certificate, temperature - Extension of calibration of one (1) additional test temperature specified by the user in the center of the usable space, including certificate
Temperature measurement, 9 measuring points - Temperature measurement with 9 measuring points with a set value specified by the user, including certificate
Temperature measurement, 18 measuring points - Temperature measurement with 18 measuring points with a set value specified by the user, including certificate
Temperature measurement, 27 measuring points - Temperature measurement with 27 measuring points with a set value specified by the user, including certificate
Execution of IQ/OQ/PQ - Execution of IQ/OQ/PQ in accordance with qualification folder
BRONZE 3-year maintenance contract - Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts
Unit commissioning - Connect the unit to the customer-side connections (electricity, water, wastewater, gas), basic functions check, brief operating instructions. (excl.: unpacking, setup, controller instructions, programming, installation work)
Unit instructions - Instruction regarding operating principle and basic functions of the unit, operation of the control electronics including programming
1-year warranty extension - The warranty is extended by 1 year from the delivery date, wear parts are excluded
Execution of IQ/OQ - Execution of IQ/OQ in accordance with qualification folder
SILVER 3-year maintenance contract - Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts, testing of all key functions, calibration of one test temperature specified by the user in the center of the usable space, without certificate
GOLD 3-year maintenance contract - Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts, testing of all key functions, replacement of wear parts, calibration of one test temperature specified by the user in the center of the usable space, including certificate
Maintenance - One-off maintenance service in accordance with maintenance schedule. Visual inspection of mechanical and electrical components, testing of all key functions. Calibration of a test temperature specified by the user in center of usable space without certificate
Calibration certificate, temperature - Calibration of one (1) test temperature specified by the user in center of chamber, including certificate
Measurement of air exchange rate - including certificate (in accordance with ASTM D5374)