Model 260
Model 260
Model 260
Model 260
Dimensions
Product image
Product image
Product image
Product image
Product image

Model M 260 | Drying and heating chambers with forced convection and advanced program functions

Benefits
  • Uniform drying conditions thanks to APT.line™ technology
  • Identical test conditions throughout the chamber interior independent of sample size and quantity
  • Outstanding thermal insulation saves operation costs
  • Advanced programming options

Configure your product with options and accessories and request it directly here.

Product description

With a maximum of +300 °C and various programming options the M series material test chambers are ideal for material and aging tests. With a high air flow, the powerful fans ensure rapid heating.

Important characteristics

  • Temperature range: +14°C above ambient temperature up to +300°C
  • High temperature accuracy thanks to APT.line™ technology with increased heating output
  • Reinforced fan with adjustable speed
  • Electromechanical control of the exhaust air flap
  • Intuitive touchscreen controller with time-segment and real-time programming
  • 2 chrome-plated racks
  • Class 2 independent adjustable temperature safety device (DIN 12880) and class 3.1 independent temperature safety device (DIN 12880) with visual/acoustic alarm available for selection on the controller
  • Failsafe function – backup sensor Pt 100
  • Computer interface: Ethernet
  • Internal data logger, measured values can be read out in open format via USB

Technical specifications

Data
Designation

M260-400V

Article Number9010-0373
Option model

Standard

Performance Data Temperature
Temperature range+14 °C above ambient temperature to 300 °C
Temperature uniformity at 150°C1.5 ± K
Temperature fluctuation at 150°C0.4 ± K
Heating up time to 150°C13 min
Recovery time after door was opened for 30 s at 150°C6 min
Air change data
Air change rate at 100°C65 x/h
Electrical data
Rated Voltage400 V
Power frequency50/60 Hz
Nominal power3,1 kW
Unit fuse16,0 A
Phase (Nominal voltage)3~/N/PE
Dimensions and weights
Interior volume256 L
Net weight of the unit (empty)86 kg
Load per rack40 kg
Permitted load270 kg
Wall clearance back160 mm
Wall clearance sidewise100 mm
Housing dimensions not incl. fittings and connections
Width net810 mm
Height net962 mm
Depth net786 mm
Internal Dimensions
Interior width650 mm
Interior height780 mm
Interior depth505 mm
Unit doors1
Environment-specific data
Sound-pressure level46 dB(A)
Energy consumption at 100°C370 Wh/h
Energy consumption at 150°C560 Wh/h
Fixtures
Number of shelves (std./max.)2/8

Downloads

Drying and heating chambers

ED | ED-S | FD | FD-S | FED | FP | M series

pdf, 2.21 MB

Series M Avantgarde.Line

pdf, 11 MB

Data Sheet Model M 260

pdf, 483.21 KB

Options, Accessories, Services

Sorry, no result could be found. Check the spelling or use a new search term.

Rubber pads

Set anti-slip feet

8012-2030

Rack

Max. load per rack 40 kg. chrome plated

8012-2042

Shelves

Rack - chrome plated

Rack

Max. load per rack 40 kg. stainless steel

8012-2169

Shelves

Rack - stainless steel

Shelf, perforated

Max. load per rack 40 kg. Stainless steel

8012-2177

Shelf

Shelf, perforated - Stainless steel

Rack, heavy load

Max. load per rack 70 kg. Stainless steel

8012-2184

Reinforced shelf racks

Rack, heavy load - Stainless steel

Table on castors

Stable cart, casters with locking brakes, dimensions: W 1,300 x D 800 x H 780 mm

9051-0019

Base

The base equipped with casters is used for the secure positioning and leveling of a BINDER drying and heating chamber

9051-0034

APT-COM™ 4 BASIC-Edition

For simple logging and documentation requirements with up to 5 networked units.. version 4, BASIC edition 

9053-0039

Multi Management Software APT-COM™

APT-COM™ 4 BASIC-Edition - for simple logging and documentation requirements with up to 5 networked units.

APT-COM™ 4 PROFESSIONAL-Edition

Convenient unit and user management built on the BASIC edition. Suitable for networking up to 100 units.. version 4, PROFESSIONAL edition

9053-0040

Multi Management Software APT-COM™

APT-COM™ 4 PROFESSIONAL-Edition - convenient unit and user management built on the BASIC edition. Suitable for networking up to 100 units.

APT-COM™ 4 GLP-Edition

For working under GLP-compliant conditions. Measured values are documented in a tamper-proof way in line with the requirements of FDA Regulation 21 CFR 11.. version 4, GLP edition

9053-0042

Multi Management Software APT-COM™

APT-COM™ 4 GLP-Edition - for working under GLP-compliant conditions. Measured values are documented in a tamper-proof way in line with the requirements of FDA Regulation 21 CFR 11.

pH-neutral detergent

Concentrated, for gentle remove of residual contaminants; 1 kg

8012-2250

1002-0016-Neutralreiniger-100x85_Web_670x515.jpg

pH-neutral detergent - concentrated, for gentle remove of residual contaminants; 1 kg

Qualification documents

IQ/OQ documents – supporting documents for validation performed by customers, consisting of: IQ/OQ checklists incl. calibration guide and comprehensive unit documentation; parameters: temperature, CO2, O2, pressure, depending on unit. Hard copy inside folder

7007-0001

Qualification documents

IQ/OQ documents – supporting documents for validation performed by customers, consisting of: IQ/OQ checklists incl. calibration guide and comprehensive unit documentation; parameters: temperature, CO2, O2, pressure, depending on unit. Digital in PDF format

7057-0001

Qualification documents

IQ/OQ/PQ documents – supporting documents for validation performed by customers, according to customer requirements, PQ section added to qualification folder IQ/OQ; parameters: temperature, CO2, O2 – or pressure, depending on unit. Hard copy inside folder

7007-0005

Qualification documents

IQ/OQ/PQ documents – supporting documents for validation performed by customers, according to customer requirements, PQ section added to qualification folder IQ/OQ; parameters: temperature, CO2, O2 – or pressure, depending on unit. Digital in PDF format

7057-0005

Sorry, no result could be found. Check the spelling or use a new search term.

Door lock

Lockable door handle

8012-2335

Door lock

Door lock - lockable door handle

Analog output 4-20 mA

For temperature values (output not adjustable)

8012-2295

Access port with silicone plug

Left. 10 mm

8012-2296

Access port with silicone plug

Access port with silicone plug - 10 mm, left

Access port with silicone plug

Top. 10 mm

8012-2297

Access port with silicone plug

Access port with silicone plug - 10 mm, top

Access port with silicone plug

Right. 10 mm

8012-2298

Access port with silicone plug

Access port with silicone plug - 10 mm, right

Access port with silicone plug

Top. 100 mm

8012-2300

Access port with silicone plug

Access port with silicone plug - 100 mm, top

Access port with silicone plug

Left. 30 mm

8012-2302

Access port with silicone plug

Access port with silicone plug - 30 mm, left

Access port with silicone plug

Top. 30 mm

8012-2303

Access port with silicone plug

Access port with silicone plug - 30 mm, top

Access port with silicone plug

Right. 30 mm

8012-2304

Access port with silicone plug

Access port with silicone plug - 30 mm, right

Access port with silicone plug

Left. 50 mm

8012-2305

Access port with silicone plug

Access port with silicone plug - 50 mm, left

Access port with silicone plug

Top. 50 mm

8012-2306

Access port with silicone plug

Access port with silicone plug - 50 mm, top

Access port with silicone plug

Right. 50 mm

8012-2307

Access port with silicone plug

Access port with silicone plug - 50 mm, right

Calibration certificate, temperature

For temperature, measurement in center of chamber at specified temperature

8012-2324

Calibration certificate, temperature

Temperature measurement incl. certificate, 15- 18 measuring points at specified temperature

8012-2325

Calibration certificate, temperature

Temperature measurement incl. certificate and 27 measuring points at specified temperature

8012-2326

Calibration certificate, temperature

Temperature measurement incl. certificate, 9 measuring points at specified temperature

8012-2327

Calibration certificate, expanded

For temperature; for extending the measurement in center of chamber to include another test temperature

8012-2328

Measurement of air exchange rate

In accordance with ASTM D5374, definition and protocol according to ambient temperature

8012-2329

Pt 100 temperature sensor

Additional flexible Pt 100, interior, for displaying the temperature on the unit display. (Not combined with specimen temperature control option)

8012-2330

Pt 100 temperature sensor

Pt 100 temperature sensor - Additional flexible Pt 100, interior, for displaying the temperature on the unit display. (Not combined with specimen temperature control option)

Specimen temperature control

With additional specimen temperature sensor. Standard function 2 zero-voltage relay contacts not applicable

8012-2343

Temperature measurement of the specimen with Pt 100 sensor

Specimen temperature control - With additional specimen temperature sensor. Standard function 2 zero-voltage relay contacts not applicable.

Access port with silicone plug

Left. 100 mm

8012-2299

Access port with silicone plug

Access port with silicone plug - 100 mm, left

Access port with silicone plug

Right. 100 mm

8012-2301

Access port with silicone plug

Access port with silicone plug - 100 mm, right

Gas-tight option model

Incl. additional measures for the greatest possible impermeability to gas; not in conjunction with access port or interior lighting option

8012-2310

HEPA air filter

On fresh air supply for unit; filter classification H14 (acc. to. EN 1822-1:2009, > 99.995% at 0.3 µm); not in conjunction with reinforced heating output, reinforced fan

8012-2313

HEPA air filter

HEPA air filter - On fresh air supply for unit; filter classification H14 (acc. to. EN 1822-1:2009, > 99.995% at 0.3 µm); not in conjunction with reinforced heating output, reinforced fan

Inert gas connection

With gas inlet and outlet, Ø 10 mm, incl. additional measures for the greatest possible impermeability to gas; not in conjunction with access port or interior lighting option

8012-2317

Inner chamber, reinforced

Max. total load 300 kg

8012-2322

Door gasket

Made of FKM, silicone-free

8012-2333

Door gasket

Door gasket - made of FKM, silicone-free  

Interior lighting

With 27 W light bulb. 230/240 V option model

8012-2318

Sorry, no result could be found. Check the spelling or use a new search term.

Calibration certificate, temperature

Extension of calibration of one (1) additional test temperature specified by the user in the center of the usable space, including certificate

DL30-0102

Services

Calibration certificate, temperature - Extension of calibration of one (1) additional test temperature specified by the user in the center of the usable space, including certificate

Temperature measurement, 9 measuring points

Temperature measurement with 9 measuring points with a set value specified by the user, including certificate

DL30-0109

Services

Temperature measurement, 9 measuring points - Temperature measurement with 9 measuring points with a set value specified by the user, including certificate

Temperature measurement, 18 measuring points

Temperature measurement with 18 measuring points with a set value specified by the user, including certificate

DL30-0118

Services

Temperature measurement, 18 measuring points - Temperature measurement with 18 measuring points with a set value specified by the user, including certificate

Temperature measurement, 27 measuring points

Temperature measurement with 27 measuring points with a set value specified by the user, including certificate

DL30-0127

Services

Temperature measurement, 27 measuring points - Temperature measurement with 27 measuring points with a set value specified by the user, including certificate

Execution of IQ/OQ

Execution of IQ/OQ in accordance with qualification folder

DL41-0200

Services

Execution of IQ/OQ - Execution of IQ/OQ in accordance with qualification folder

Execution of IQ/OQ/PQ

Execution of IQ/OQ/PQ in accordance with qualification folder

DL44-0500

Services

Execution of IQ/OQ/PQ - Execution of IQ/OQ/PQ in accordance with qualification folder

BRONZE 3-year maintenance contract

Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts

DL20-0720

Services

BRONZE 3-year maintenance contract - Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts

Unit commissioning

Connect the unit to the customer-side connections (electricity, water, wastewater, gas), basic functions check, brief operating instructions. (excl.: unpacking, setup, controller instructions, programming, installation work) 

DL10-0100

Services

Unit commissioning - Connect the unit to the customer-side connections (electricity, water, wastewater, gas), basic functions check, brief operating instructions. (excl.: unpacking, setup, controller instructions, programming, installation work) 

Unit instructions

Instruction regarding operating principle and basic functions of the unit, operation of the control electronics including programming

DL10-0500

Services

Unit instructions - Instruction regarding operating principle and basic functions of the unit, operation of the control electronics including programming

1-year warranty extension

The warranty is extended by 1 year from the delivery date, wear parts are excluded

DL50-0010

Services

1-year warranty extension - The warranty is extended by 1 year from the delivery date, wear parts are excluded

SILVER 3-year maintenance contract

Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts, testing of all key functions, calibration of one test temperature specified by the user in the center of the usable space, without certificate 

DL20-0810

Services

SILVER 3-year maintenance contract - Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts, testing of all key functions, calibration of one test temperature specified by the user in the center of the usable space, without certificate 

GOLD 3-year maintenance contract

Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts, testing of all key functions, replacement of wear parts, calibration of one test temperature specified by the user in the center of the usable space, including certificate

DL20-0910

Services

GOLD 3-year maintenance contract - Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts, testing of all key functions, replacement of wear parts, calibration of one test temperature specified by the user in the center of the usable space, including certificate

Maintenance

One-off maintenance service in accordance with maintenance schedule. Visual inspection of mechanical and electrical components, testing of all key functions. Calibration of a test temperature specified by the user in center of usable space without certificate

DL20-0602

Services

Maintenance - One-off maintenance service in accordance with maintenance schedule. Visual inspection of mechanical and electrical components, testing of all key functions. Calibration of a test temperature specified by the user in center of usable space without certificate

Calibration certificate, temperature

Calibration of one (1) test temperature specified by the user in center of chamber, including certificate

DL30-0120

Services

Calibration certificate, temperature - Calibration of one (1) test temperature specified by the user in center of chamber, including certificate

Measurement of air exchange rate

Including certificate (in accordance with ASTM D5374)

DL33-0000

Services

Measurement of air exchange rate - including certificate (in accordance with ASTM D5374)

Suggested products

Compare products:

Or add another product.