Model MKFT 115 | Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range
Benefits
- Homogeneous climate conditions thanks to APT.line™ technology
- Automatic water and wastewater management
- Pressure humidification with fast response times
- Comprehensive programming and data acquisition
- Large heated viewing window
Product description
The BINDER MKFT series environmental simulation chamber for low temperature alternating climate profiles is the specialist for dynamic alternating climate change between -70 °C and 180 °C. Large performance reserves and rapid cooling make the MKFT environmental simulation chamber the high-end product for complex standards-based climate tests.
Important characteristics
- Temperature range: -70 °C to +180 °C
- Humidity range: 10 % to 98 % RH
- Integrated water-storage tank, 20 liters
- 4 zero-voltage relay contacts
- APT.line™ preheating chamber technology
- Programmable condensation protection for test material
- Intuitive touchscreen controller with time-segment and real-time programming
- Internal data logger, measured values can be read out in open format via USB
- Heated viewing window with LED interior lighting
- Humidity regulation with capacitative humidity sensor and vapor humidification
- BINDER Multi Management Software APT-COM™ Basic Edition
- Troubleshooting system with visual and audible alarms
- Class 2 independent adjustable temperature safety device (DIN 12880) with visual alarm
- Access port with silicone plug: 50 mm, left
- 4 castors, two with brakes
- Computer interface: Ethernet
- Adjustable ramp function
- Integrated chart recorder
- Real-time clock
- Door heating
- Alarm notification in the event of insufficient water in fresh water tank
- 1 stainless steel rack
- Complete safety connection kit for water supply and drainage, up to 1 m in height
- Inner chamber made of stainless steel
- CFC-free refrigerants R-452A and R-23
- Cooling with cascade compressor cooling unit
Technical specifications
| Data | ||
| Designation | MKFT115-400V | MKFT115-480V-C |
| Article Number | 9020-0382 | 9020-0362 |
| Option model | Standard | with voltage and frequency converter |
| Performance Data Temperature | ||
| Temperature range | -70...180 °C | -70...180 °C |
| Temperature uniformity dependent on set value | 0.1...1.3 ± K | 0.1...1.3 ± K |
| Temperature fluctuation dependent on set value | 0.1...0.1 ± K | 0.1...0.1 ± K |
| Average heating-up rate according to IEC 60068-3-5 | 5.5 K/min | 5.5 K/min |
| Cooling down time from 180°C to -70°C | 120 min | 120 min |
| Average cooling down time according to IEC 60068-3-5 | 4.2 K/min | 4.2 K/min |
| Performance Data Climate | ||
| Temperature range with humidity | 10...90 °C | 10...90 °C |
| Humidity range | 95 % RH...10 | 95 % RH...10 |
| Temperature fluctuation with humidity dependent on set value | 0.1...1 ± K | 0.1...1 ± K |
| Humidity fluctuation with humidity dependent on set value | ≤2,5 ± % r.F. | ≤2,5 ± % r.F. |
| Max. heat compensation at 25°C and 90% RH | 400 W | 400 W |
| Electrical data | ||
| Rated Voltage | 400 V | 480 V |
| Power frequency | 50 Hz | 60 Hz |
| Nominal power | 5 kW | 5 kW |
| Unit fuse | 16,0 A | 16,0 A |
| Phase (Nominal voltage) | 3~/N/PE | 3~ |
| Dimensions and weights | ||
| Interior volume | 115 L | 115 L |
| Net weight of the unit (empty) | 330 kg | 494 kg |
| Load per rack | 30 kg | 30 kg |
| Permitted load | 60 kg | 60 kg |
| Wall clearance back | 300 mm | 300 mm |
| Wall clearance sidewise | 200 mm | 200 mm |
| Housing dimensions not incl. fittings and connections | ||
| Width net | 980 mm | 980 mm |
| Height net | 1,725 mm | 1,725 mm |
| Depth net | 865 mm | 865 mm |
| Internal Dimensions | ||
| Interior width | 600 mm | 600 mm |
| Interior height | 480 mm | 480 mm |
| Interior depth | 400 mm | 400 mm |
| Unit doors | 1 | 1 |
| Environment-specific data | ||
| Sound-pressure level | 64 dB(A) | 67 dB(A) |
| Energy consumption at 25°C and 60% RH | 1,000 Wh/h | 1,000 Wh/h |
| Fixtures | ||
| Number of shelves (std./max.) | 1/4 | 1/4 |
Downloads
Options, Accessories, Services
Sorry, no result could be found. Check the spelling or use a new search term.
Rack - stainless steel
BINDER PURE AQUA SERVICE - System for preparation or complete desalination of tap water, complete set containing PURE AQUA 300 single-use cartridge, measuring device, and all necessary connecting parts
BINDER PURE AQUA SERVICE, accessories - Single-use, replacement cartridge for BINDER PURE AQUA System
Rack, reinforced - stainless steel, with fasteners (1 set of 4)
APT-COM™ 4 PROFESSIONAL-Edition - convenient unit and user management built on the BASIC edition. Suitable for networking up to 100 units.
APT-COM™ 4 GLP-Edition - for working under GLP-compliant conditions. Measured values are documented in a tamper-proof way in line with the requirements of FDA Regulation 21 CFR 11.
pH-neutral detergent - concentrated, for gentle remove of residual contaminants; 1 kg
Sorry, no result could be found. Check the spelling or use a new search term.
Dry-air purge - controlled, incl. connection; suitable for the simulation of current automobile industry standards
Notch-type access port - notch-type access port in door, 100 x 35 mm
Access port with silicone plug - 30 mm, right
Access port with silicone plug - 30 mm, left
Access port with silicone plug - 50 mm, right
Access port with silicone plug - 50 mm, left
Access port with silicone plug - 80 mm, right
Access port with silicone plug - 80 mm, left
Access port with silicone plug - 125 mm, right
Access port with silicone plug - 125 mm, left
Access port with silicone plug - 100 mm, top
Access port with silicone plug - 125 mm, top
Access port with silicone plug - 80 mm, top
Access port with silicone plug - 100 mm, right
Access port with silicone plug - 100 mm, left
Door lock - lockable door handle
Pt 100 temperature sensor - additional flexible Pt 100, interior, for displaying the temperature on the unit display
Sorry, no result could be found. Check the spelling or use a new search term.
BRONZE 3-year maintenance contract - Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts
Execution of IQ/OQ/PQ - Execution of IQ/OQ/PQ in accordance with qualification folder
Unit commissioning - Connect the unit to the customer-side connections (electricity, water, wastewater, gas), basic functions check, brief operating instructions. (excl.: unpacking, setup, controller instructions, programming, installation work)
Unit instructions - Instruction regarding operating principle and basic functions of the unit, operation of the control electronics including programming
Leakage test - Testing and logging of the leak-tightness of systems containing hydrofluorocarbons in accordance with Regulation EC842/2006, incl. test book
1-year warranty extension - The warranty is extended by 1 year from the delivery date, wear parts are excluded
Maintenance - One-off maintenance service in accordance with maintenance schedule. Visual inspection of mechanical and electrical components, testing of all key functions. Calibration of a test temperature specified by the user in center of usable space without certificate
SILVER 3-year maintenance contract - Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts, testing of all key functions, calibration of one test temperature specified by the user in the center of the usable space, without certificate
GOLD 3-year maintenance contract - Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts, testing of all key functions, replacement of wear parts, calibration of one test temperature specified by the user in the center of the usable space, including certificate
Temperature and humidity calibration - Expansion –Temperature and humidity calibration with 1 measuring point in center of chamber with 1 specified pair of values, including certificate
Temperature measurement 9 temperature measuring points and 1 humidity measuring point - including certificate, 9 temperature measuring points and 1 humidity measuring point in center of chamber, at 25 °C / 60 % RH or at specified values - for MKF, KMF, KBF, KBF P, KBF LQC, KBWF, MKFT Series
Temperature measurement 18 temperature measuring points and 1 humidity measuring point - including certificate, 18 temperature measuring points and 1 humidity measuring point in center of chamber, at 25 °C / 60 % RH or at specified values - for MKF, KMF, KBF, KBF P, KBF LQC, KBWF, MKFT Series
Temperature measurement 27 temperature measuring points and 1 humidity measuring point - including certificate, 27 temperature measuring points and 1 humidity measuring point in center of chamber, at 25 °C / 60 % RH or at specified values - for MKF, KMF, KBF, KBF P, KBF LQC, KBWF, MKFT Series
Calibration temperature and humidity - including certificate, one measuring point in center of chamber at 25 °C / 60 % RH or at specified values
Temperature and humidity measurement according to DIN12880 - including certificate (27 temperature measuring points and 1 humidity measuring point, at 25 °C / 60 % RH or at specified values)
Execution of IQ/OQ - Execution of IQ/OQ in accordance with qualification folder