Model 1020
Model 1020
Model 1020
Model 1020
Model 1020
Dimensions
Heating up rate
Cooling down rate
Heat compensation chart
Product image
Product image
Product image
Product image
Product image
Product image
Product image
Product image
Product image

Model MK 1020 CO₂ | Dynamic climate chambers for rapid temperature changes

Benefits
  • More performance for your budget and long-term investment security
  • Easy to integrate, intuitive to use, and flexible to network
  • Reliable protection for samples, data, and processes
  • Reproducible results and long-term operational stability

Configure your product with options and accessories and request it directly here.

Product description

The environmental simulation chambers in the MK CO₂ series are designed for dynamic temperature tests and complex temperature profiles. High alternating speeds facilitate rapid temperature changes and ensure that tests are conducted in accordance with standards and are reproducible. A comprehensive list of standard features ensures incredible value for money. The MK CO₂ series uses natural CO₂ as a refrigerant, offering an alternative for applications with specific refrigeration requirements.

Important characteristics

  • Temperature range: -48°C to +180°C
  • APT.line™ preheating chamber technology
  • Cooling with R744, a natural CO₂ refrigerant
  • Intuitive touchscreen controller with time-segment and real-time programming
  • Ergonomically adjustable operating terminal
  • Signal triangle with light-up status display
  • Internal data logger, measured values can be read out in open format via USB
  • BINDER Multi Management Software APT-COM™ basic edition
  • Programmable condensation protection for samples
  • Troubleshooting system with visual and acoustic alarms
  • Stainless-steel inner chamber
  • 1 stainless steel rack
  • 2 access ports with silicone plugs, 80 mm, left and right
  • Heated viewing window with LED interior lighting
  • Class 2 independent adjustable temperature safety device (DIN 12880) with visual alarm
  • 4 sturdy twin casters with brakes at the front
  • Data interfaces: Ethernet, USB
  • Adjustable ramp function
  • Integrated line recorder
  • Real-time clock
  • Door heating to prevent condensation

Technical specifications

Data
Article Number9020-05279020-0529
Designation

MK1020CO2-400V

MK1020CO2-480V

Option model

Standard

Standard

Performance Data Temperature
Temperature range-48...180 °C-48...180 °C
Temperature uniformity dependent on set value0.1...1.0 ± K0.1...1.0 ± K
Temperature fluctuation dependent on set value0.1...0.2 ± K0.1...0.2 ± K
Average heating-up rate according to IEC 60068-3-5 between -40°C and 180°C6.2 K/min6.2 K/min
Average cooling down time according to IEC 60068-3-5 between 180°C and -40°C4.8 K/min4.8 K/min
Cooling down time from 180°C to -40°C70 min70 min
Electrical data
Rated Voltage400 V480 V
Power frequency50 Hz60 Hz
Nominal power9,6 kW9,6 kW
Unit fuse32,0 A32,0 A
Phase (Nominal voltage)3~/N/PE3~/N/PE
Dimensions and weights
Interior volume991 L991 L
Net weight of the unit (empty)556 kg560 kg
Load per rack40 kg40 kg
Permitted load200 kg200 kg
Wall clearance back300 mm300 mm
Wall clearance sidewise200 mm200 mm
Housing dimensions not incl. fittings and connections
Width net1,580 mm1,580 mm
Height net2,005 mm2,005 mm
Depth net1,480 mm1,480 mm
Internal Dimensions
Interior width1,200 mm1,200 mm
Interior height1,020 mm1,020 mm
Interior depth810 mm810 mm
Unit doors11
Environment-specific data
Sound-pressure level62 dB(A)62 dB(A)
Energy consumption at 25°C2,500 Wh/h2,500 Wh/h
Fixtures
Number of shelves (std./max.)1/111/11

Options, accessories & services

Sorry, no result could be found. Check the spelling or use a new search term.

Analog output 4-20 mA

For temperature values (output not adjustable)

8012-2634

Access port with silicone plug

Left. 100 mm

8012-2643

Access port with silicone plug

Access port with silicone plug - 100 mm, left

Access port with silicone plug

Top. 100 mm

8012-2644

Access port with silicone plug

Access port with silicone plug - 100 mm, top

Access port with silicone plug

Right. 100 mm

8012-2645

Access port with silicone plug

Access port with silicone plug - 100 mm, right

Access port with silicone plug

Left. 125 mm

8012-2646

Access port with silicone plug

Access port with silicone plug - 125 mm, left

Access port with silicone plug

Top. 125 mm

8012-2647

Access port with silicone plug

Access port with silicone plug - 125 mm, top

Access port with silicone plug

Right. 125 mm

8012-2648

Access port with silicone plug

Access port with silicone plug - 125 mm, right

Access port with silicone plug

Left. 30 mm

8012-2649

Access port with silicone plug

Access port with silicone plug - 30 mm, left

Access port with silicone plug

Right. 30 mm

8012-2650

Access port with silicone plug

Access port with silicone plug - 30 mm, right

Access port with silicone plug

Left. 50 mm

8012-2651

Access port with silicone plug

Access port with silicone plug - 50 mm, left

Access port with silicone plug

Right. 50 mm

8012-2652

Access port with silicone plug

Access port with silicone plug - 50 mm, right

Access port with silicone plug

Left. 80 mm

8012-2653

Access port with silicone plug

Access port with silicone plug - 80 mm, left

Access port with silicone plug

Top. 80 mm

8012-2654

Access port with silicone plug

Access port with silicone plug - 80 mm, top

Access port with silicone plug

Right. 80 mm

8012-2655

Access port with silicone plug

Access port with silicone plug - 80 mm, right

Calibration certificate, temperature

For temperature, measurement in center of chamber at specified temperature

8012-2656

Calibration certificate, temperature

Temperature measurement incl. certificate, 15- 18 measuring points at specified temperature

8012-2657

Calibration certificate, temperature

Temperature measurement incl. certificate and 27 measuring points at specified temperature

8012-2658

Calibration certificate, temperature

Temperature measurement incl. certificate, 9 measuring points at specified temperature

8012-2659

Calibration certificate, expanded

For temperature; for extending the measurement in center of chamber to include another test temperature

8012-2660

Zero voltage relay contacts

For controlling 3 relay contacts via program regulators, accessible via 6-pin DIN socket (max. 24 V - 2.5 A)

8012-2664

RS 485 interface, 2-wire

Additional serial interface can be used parallel to Ethernet, for Multi Management Software APT-COM™

8012-2665

Pt 100 temperature sensor

Additional flexible Pt 100, interior, for displaying the temperature on the unit display

8012-2667

Pt 100 temperature sensor

Pt 100 temperature sensor - additional flexible Pt 100, interior, for displaying the temperature on the unit display

Door lock

Lockable door handle

8012-2669

Door lock

Door lock - lockable door handle

Sorry, no result could be found. Check the spelling or use a new search term.

Maintenance

One-off maintenance service in accordance with maintenance schedule. Visual inspection of mechanical and electrical components, testing of all key functions. Calibration of a test temperature specified by the user in center of usable space without certificate

DL20-0607

Services

Maintenance - One-off maintenance service in accordance with maintenance schedule. Visual inspection of mechanical and electrical components, testing of all key functions. Calibration of a test temperature specified by the user in center of usable space without certificate

BRONZE 3-year maintenance contract

Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts

DL20-0710

Services

BRONZE 3-year maintenance contract - Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts

SILVER 3-year maintenance contract

Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts, testing of all key functions, calibration of one test temperature specified by the user in the center of the usable space, without certificate 

DL20-0830

Services

SILVER 3-year maintenance contract - Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts, testing of all key functions, calibration of one test temperature specified by the user in the center of the usable space, without certificate 

GOLD 3-year maintenance contract

Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts, testing of all key functions, replacement of wear parts, calibration of one temperature/humidity/pressure value, including certificate

DL20-0930

Services

GOLD 3-year maintenance contract - Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts, testing of all key functions, replacement of wear parts, calibration of one temperature/humidity/pressure value, including certificate

Calibration certificate, temperature

Extension of calibration of one (1) additional test temperature specified by the user in the center of the usable space, including certificate

DL30-0102

Services

Calibration certificate, temperature - Extension of calibration of one (1) additional test temperature specified by the user in the center of the usable space, including certificate

Temperature measurement, 9 measuring points

Temperature measurement with 9 measuring points with a set value specified by the user, including certificate

DL30-0109

Services

Temperature measurement, 9 measuring points - Temperature measurement with 9 measuring points with a set value specified by the user, including certificate

Temperature measurement, 18 measuring points

Temperature measurement with 18 measuring points with a set value specified by the user, including certificate

DL30-0118

Services

Temperature measurement, 18 measuring points - Temperature measurement with 18 measuring points with a set value specified by the user, including certificate

Temperature measurement, 27 measuring points

Temperature measurement with 27 measuring points with a set value specified by the user, including certificate

DL30-0127

Services

Temperature measurement, 27 measuring points - Temperature measurement with 27 measuring points with a set value specified by the user, including certificate

Calibration certificate, temperature

Calibration of one (1) test temperature specified by the user in center of chamber, including certificate

DL30-0130

Services

Calibration certificate, temperature - Calibration of one (1) test temperature specified by the user in center of chamber, including certificate

Execution of IQ/OQ

Execution of IQ/OQ in accordance with qualification folder

DL41-0200

Services

Execution of IQ/OQ - Execution of IQ/OQ in accordance with qualification folder

Execution of IQ/OQ/PQ

Execution of IQ/OQ/PQ in accordance with qualification folder

DL44-0500

Services

Execution of IQ/OQ/PQ - Execution of IQ/OQ/PQ in accordance with qualification folder

1-year warranty extension

The warranty is extended by 1 year from the delivery date, wear parts are excluded

DL50-0040

Services

1-year warranty extension - The warranty is extended by 1 year from the delivery date, wear parts are excluded

Unit commissioning

Connect the unit to the customer-side connections (electricity, water, wastewater, gas), basic functions check, brief operating instructions. (excl.: unpacking, setup, controller instructions, programming, installation work) 

DL10-0170

Services

Unit commissioning - Connect the unit to the customer-side connections (electricity, water, wastewater, gas), basic functions check, brief operating instructions. (excl.: unpacking, setup, controller instructions, programming, installation work) 

Unit instructions

Instruction regarding operating principle and basic functions of the unit, operation of the control electronics including programming

DL10-0560

Services

Unit instructions - Instruction regarding operating principle and basic functions of the unit, operation of the control electronics including programming

Sorry, no result could be found. Check the spelling or use a new search term.

Rack

Stainless steel

8012-2124

Shelves

Rack - stainless steel

Rack, reinforced

Stainless steel

8012-2105

Shelf

Rack, reinforced - stainless steel

Shelf, perforated

Stainless steel

8012-2261

Shelf

Shelf, perforated - Stainless steel

RS 485 / RS 422 interface converter

RS 422 cable set and RS 485 / RS 422 interface converter for connection to 10-way plug distributor. 115 V option model

8012-0599

RS 485 / RS 422 interface converter

RS 422 cable set and RS 485 / RS 422 interface converter for connection to 10-way plug distributor. 230 V option model

8012-0589

APT-COM™ 4 PROFESSIONAL-Edition

Convenient unit and user management built on the BASIC edition. Suitable for networking up to 100 units.. version 4, PROFESSIONAL edition

9053-0040

Multi Management Software APT-COM™

APT-COM™ 4 PROFESSIONAL-Edition - convenient unit and user management built on the BASIC edition. Suitable for networking up to 100 units.

APT-COM™ 4 GLP-Edition

For working under GLP-compliant conditions. Measured values are documented in a tamper-proof way in line with the requirements of FDA Regulation 21 CFR 11.. version 4, GLP edition

9053-0042

Multi Management Software APT-COM™

APT-COM™ 4 GLP-Edition - for working under GLP-compliant conditions. Measured values are documented in a tamper-proof way in line with the requirements of FDA Regulation 21 CFR 11.

pH-neutral detergent

Concentrated, for gentle remove of residual contaminants; 1 kg

8012-2250

1002-0016-Neutralreiniger-100x85_Web_670x515.jpg

pH-neutral detergent - concentrated, for gentle remove of residual contaminants; 1 kg

Qualification documents

IQ/OQ documents – supporting documents for validation performed by customers, consisting of: IQ/OQ checklists incl. calibration guide and comprehensive unit documentation; parameters: temperature, CO2, O2, pressure, depending on unit. Hard copy inside folder

7007-0001

Qualification documents

IQ/OQ documents – supporting documents for validation performed by customers, consisting of: IQ/OQ checklists incl. calibration guide and comprehensive unit documentation; parameters: temperature, CO2, O2, pressure, depending on unit. Digital in PDF format

7057-0001

Qualification documents

IQ/OQ/PQ documents – supporting documents for validation performed by customers, according to customer requirements, PQ section added to qualification folder IQ/OQ; parameters: temperature, CO2, O2 – or pressure, depending on unit. Hard copy inside folder

7007-0005

Qualification documents

IQ/OQ/PQ documents – supporting documents for validation performed by customers, according to customer requirements, PQ section added to qualification folder IQ/OQ; parameters: temperature, CO2, O2 – or pressure, depending on unit. Digital in PDF format

7057-0005

Downloads

2026-10_BR_Product-overview_EN.pdf

pdf, 7.72 MB

7001-0714-EN_MK-CO2_E6_UM_09-2026.pdf

pdf, 9.98 MB

Safety Instructions

MK | MKF serie

pdf, 3.09 MB

Data Sheet ModelMK 1020

pdf, 832.18 KB

Suggested products

Compare products:

Or add another product.