Benefits
  • Safe thanks to climatic homogeneity that far exceeds the accuracy required by ICH guidelines, even with a fully loaded unit.
  • Reliable thanks to failsafe operation without compromise. The interior and Longlife evaporator plate are made entirely from stainless steel. 
  • Smart, as a wide range of accessories makes it highly compatible for adaptation to specific customer requirements.
  • Economical thanks to maximum effective volume which allows for 30% larger load compared to the competition.

 

Configure your product with options and accessories and request it directly here.

Product description

The BINDER KBF is the specialist for unconditionally reliable stability testing and precise maintenance of constant climate conditions. From programming to documentation, this constant climate chamber meets all critical requirements.

Important characteristics

  • Temperature range: 0 °C to +70 °C
  • Humidity range: 10 % to 80 % RH
  • APT.line™ preheating chamber technology
  • Humidity regulation with capacitive humidity sensor and vapor humidification
  • Intuitive touchscreen controller with time-segment and real-time programming
  • BINDER Multi Management Software APT-COM™ Basic Edition
  • Internal data logger, measured values can be read out in open format via USB
  • Unit self-test for comprehensive status analysis
  • Tight-sealing inner door made of safety glass (ESG)
  • Avoidance of glass corrosion by special TIMELESS coating
  • Inner chamber made of stainless steel
  • 2 stainless steel racks
  • Access port with silicone plug, 30 mm, left
  • 4 stable castors, two with brakes, from 240 liters
  • Class 3.1 independent temperature safety device (DIN 12880) with visual and audible temperature alarm
  • Computer interface: Ethernet
  • Door heating

 

Technical specifications

Designation KBF1020-230V¹ KBF1020-240V¹
Option model Standard Standard
Order number 9020-0326 9020-0327
Data
Serie KBF KBF
Performance Data Temperature
Max. heat compensation at 40 °C [W] 600 600
Temperature fluctuation [± K] 0.5 0.5
Temperature range 0…70 0…70
Temperature variation at 40 °C [± K] 0.2 0.2
Performance Data Climate
Humidity fluctuation at 25 °C and 60 % RH 1,5 ± % RH 1,5 ± % RH
Humidity fluctuation at 40 °C and 75 % RH 1,5 ± % RH 1,5 ± % RH
Humidity range 10…80 10…80
Recovery time after 30 seconds door open at 25 °C and 60 % RH [min] 11 11
Recovery time after 30 seconds door open at 40 °C and 75 % RH [min] 12 12
Temperature fluctuation at 25 °C and 60 % RH [± K] 0.1 0.1
Temperature fluctuation at 40 °C and 75 % RH [± K] 0.1 0.1
Temperature range [°C] 10…70 10…70
Temperature variation at 25 °C and 60 % RH [± K] 0.2 0.2
Temperature variation at 40 °C and 75 % RH [± K] 0.2 0.2
Electrical data
Nominal power [kW] 3.1 3.1
Phase (Nominal voltage) 1~ 1~
Power frequency [Hz] 50/60 50/60
Rated Voltage [V] 200…230 200…240
Unit fuse [A] 16 16
Doors
Inner doors 2 2
Unit doors 2 2
Housing dimensions not incl. fittings and connections
Depth net [mm] 1145 1145
Height net [mm] 1925 1925
Width net [mm] 1250 1250
Internal Dimensions
Depth [mm] 836 836
Height [mm] 1250 1250
Width [mm] 973 973
Measures
Interior volume [L] 1020 1020
Load per rack [kg] 45 45
Net weight of the unit (empty) [kg] 379 379
Permitted load [kg] 150 150
Wall clearance back [mm] 100 100
Wall clearance sidewise [mm] 100 100
Environment-specific data
Energy consumption at 40 °C and 75 % RH [Wh/h] 650 650
Sound-pressure level [dB(A)] 56 56
Fixtures
Number of shelves (std./max.) 2/15 2/15
Performance Data Temperature
Max. heat compensation at 40 °C [W] 600 600
Temperature fluctuation [± K] 0.5 0.5
Temperature range 0…70 0…70
Temperature variation at 40 °C [± K] 0.2 0.2
Performance Data Climate
Humidity fluctuation at 25 °C and 60 % RH 1,5 ± % RH 1,5 ± % RH
Humidity fluctuation at 40 °C and 75 % RH 1,5 ± % RH 1,5 ± % RH
Humidity range 10…80 10…80
Recovery time after 30 seconds door open at 25 °C and 60 % RH [min] 11 11
Recovery time after 30 seconds door open at 40 °C and 75 % RH [min] 12 12
Temperature fluctuation at 25 °C and 60 % RH [± K] 0.1 0.1
Temperature fluctuation at 40 °C and 75 % RH [± K] 0.1 0.1
Temperature range [°C] 10…70 10…70
Temperature variation at 25 °C and 60 % RH [± K] 0.2 0.2
Temperature variation at 40 °C and 75 % RH [± K] 0.2 0.2
Electrical data
Nominal power [kW] 3.1 3.1
Phase (Nominal voltage) 1~ 1~
Power frequency [Hz] 50/60 50/60
Rated Voltage [V] 200…230 200…240
Unit fuse [A] 16 16
Doors
Inner doors 2 2
Unit doors 2 2
Housing dimensions not incl. fittings and connections
Depth net [in] 45.1 45.1
Height net [in] 75.8 75.8
Width net [in] 49.3 49.3
Internal Dimensions
Depth [in] 32.94 32.94
Height [in] 49.3 49.3
Width [in] 38.34 38.34
Measures
Interior volume [cu.ft.] 36 36
Load per rack [lbs] 99 99
Net weight of the unit (empty) [lbs] 836 836
Permitted load [lbs] 331 331
Wall clearance back [in] 3.94 3.94
Wall clearance sidewise [in] 3.94 3.94
Environment-specific data
Energy consumption at 40 °C and 75 % RH [Wh/h] 650 650
Sound-pressure level [dB(A)] 56 56
Fixtures
Number of shelves (std./max.) 2/15 2/15

Downloads

Constant climate chambers

pdf

PURE AQUA SERVICE

pdf

Water supply systems

pdf

LED light bar sets

pdf

Constant climate chambers (KBF series) - Putting labels through their paces in BINDER chambers

pdf

Constant climate chambers (KBF series) - Desiccants – the all-round talent against corrosion damage

pdf

Constant climate chambers (KBF series) - Test the service life of surgical instruments

pdf

Constant climate chambers (KBF series) - Quality testing made quick and easy

pdf

Constant climate chambers (KBF LQC series) - Top-quality dairy products

pdf

KBF | KMF series

pdf

Data Sheet Model KBF 1020

pdf