Model BD 23 | Standard-Incubators with natural convection
Benefits
- Safe and reproducible incubation even under high batch throughputs in long-term operation
- Disinfection routine at 100 °C
- Stable atmosphere by inner glass door
Product description
The BINDER incubator of the BD series with natural convection is the specialist in long-term and stable continuous operation. This incubator is specially designed for gentle incubation of organisms, as well as conditioning of heat-sensitive media or microbiological heating.
Important characteristics
- Temperature range: +5°C above ambient temperature to +100°C
- APT.line™ preheating chamber technology
- Natural convection
- Adjustable exhaust air flap
- Controller with timer functions
- Inner door made of tempered safety glass
- 2 chrome-plated racks
- Stackable
- Class 3.1 independent temperature safety device (DIN 12880) with visual temperature alarm
- Computer interface: RS 422
Technical specifications
| Data | ||
| Designation | BD023-230V | BD023UL-120V |
| Article Number | 9010-0187 | 9010-0189 |
| Option model | Standard | Standard |
| Performance Data Temperature | ||
| Temperature range | +5 °C above ambient temperature to 100 °C | +5 °C above ambient temperature to 100 °C |
| Temperature uniformity at 37°C | 0.5 ± K | 0.5 ± K |
| Temperature fluctuation at 37°C | 0.2 ± K | 0.2 ± K |
| Heating up time to 37°C | 59 min | 59 min |
| Recovery time after door was opened for 30 s at 37°C | 20 min | 20 min |
| Electrical data | ||
| Rated Voltage | 230 V | 120 V |
| Power frequency | 50/60 Hz | 60 Hz |
| Nominal power | 0,2 kW | 0,2 kW |
| Unit fuse | 12,5 A | 12,5 A |
| Phase (Nominal voltage) | 1~ | 1~ |
| Dimensions and weights | ||
| Interior volume | 20 L | 20 L |
| Net weight of the unit (empty) | 27 kg | 27 kg |
| Load per rack | 12 kg | 12 kg |
| Permitted load | 25 kg | 25 kg |
| Wall clearance back | 100 mm | 100 mm |
| Wall clearance sidewise | 50 mm | 50 mm |
| Housing dimensions not incl. fittings and connections | ||
| Width net | 435 mm | 435 mm |
| Height net | 495 mm | 495 mm |
| Depth net | 520 mm | 520 mm |
| Internal Dimensions | ||
| Interior width | 222 mm | 222 mm |
| Interior height | 330 mm | 330 mm |
| Interior depth | 277 mm | 277 mm |
| Unit doors | 1 | 1 |
| Environment-specific data | ||
| Energy consumption at 37°C | 11 Wh/h | 11 Wh/h |
| Fixtures | ||
| Number of shelves (std./max.) | 2/4 | 2/4 |
Options, Accessories, Services
Sorry, no result could be found. Check the spelling or use a new search term.
Rack - chrome plated
Rack - stainless steel
Shelf, perforated - Stainless steel
stable cart, casters with locking brakes, dimensions: W 1,000 x D 800 x H 780 mm
APT-COM™ 4 BASIC-Edition - for simple logging and documentation requirements with up to 5 networked units.
APT-COM™ 4 PROFESSIONAL-Edition - convenient unit and user management built on the BASIC edition. Suitable for networking up to 100 units.
APT-COM™ 4 GLP-Edition - for working under GLP-compliant conditions. Measured values are documented in a tamper-proof way in line with the requirements of FDA Regulation 21 CFR 11.
pH-neutral detergent - concentrated, for gentle remove of residual contaminants; 1 kg
Sorry, no result could be found. Check the spelling or use a new search term.
Access port with silicone plug - 30 mm, top
Access port with silicone plug - 30 mm, right
Access port with silicone plug - 30 mm, left
Access port with silicone plug - 50 mm, top
Access port with silicone plug - 50 mm, right
Access port with silicone plug - 50 mm, left
Access port with silicone plug - 100 mm, top
Access port with silicone plug - 10 mm, top
Access port with silicone plug - 10 mm, right
Access port with silicone plug - 10 mm, left
Access port with silicone plug - 10 mm, back
Access port with silicone plug - 30 mm, back
Access port with silicone plug - 50 mm, back
Door lock - lockable door handle
Pt 100 temperature sensor - additional flexible Pt 100, interior, with external connection incl. LEMO connector (3-pin)
Sorry, no result could be found. Check the spelling or use a new search term.
Calibration certificate, temperature - Extension of calibration of one (1) additional test temperature specified by the user in the center of the usable space, including certificate
Temperature measurement, 9 measuring points - Temperature measurement with 9 measuring points with a set value specified by the user, including certificate
Temperature measurement, 18 measuring points - Temperature measurement with 18 measuring points with a set value specified by the user, including certificate
Temperature measurement, 27 measuring points - Temperature measurement with 27 measuring points with a set value specified by the user, including certificate
Execution of IQ/OQ/PQ - Execution of IQ/OQ/PQ in accordance with qualification folder
BRONZE 3-year maintenance contract - Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts
SILVER 3-year maintenance contract - Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts, testing of all key functions, calibration of one test temperature specified by the user in the center of the usable space, without certificate
GOLD 3-year maintenance contract - Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts, testing of all key functions, replacement of wear parts, calibration of one test temperature specified by the user in the center of the usable space, including certificate
Unit commissioning - Connect the unit to the customer-side connections (electricity, water, wastewater, gas), basic functions check, brief operating instructions. (excl.: unpacking, setup, controller instructions, programming, installation work)
Unit instructions - Instruction regarding operating principle and basic functions of the unit, operation of the control electronics including programming
Maintenance - One-off maintenance service in accordance with maintenance schedule. Visual inspection of mechanical and electrical components, testing of all key functions. Calibration of a test temperature specified by the user in center of usable space without certificate
Calibration certificate, temperature - Calibration of one (1) test temperature specified by the user in center of chamber, including certificate
1-year warranty extension - The warranty is extended by 1 year from the delivery date, wear parts are excluded
Execution of IQ/OQ - Execution of IQ/OQ in accordance with qualification folder