Benefits
Important characteristics
Details of the model
Select version
Merken | ||
---|---|---|
Model UF V 500 | ||
|
+ | |
|
+ | |
|
+ | |
|
+ |
Technical data
The PDF data sheet contains technical data, options & accessories as well as services.
Downloads
Serie CKurzanleitung
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
Rated voltage | Option model | Version | Art. No. | Selection | Bookmark | |
---|---|---|---|---|---|---|
Model UF V 500 | ||||||
240 V 1~ 60 Hz | ||||||
Standard |
UFV500UL-240V | 9020-0353 | + | |||
120 V 1~ 60 Hz | ||||||
Standard |
UFV500UL-120V | 9020-0351 | + | |||
230 V 1~ 50 Hz | ||||||
Standard |
UFV500-230V | 9020-0347 | + | |||
Water cooling |
UFV500-230V-W | 9020-0349 | + |
Designation | Description | Art. No. | Bookmark | |||
---|---|---|---|---|---|---|
5 m power cable | ||||||
C 13 refrigerator connection cable with BS 1363 British plug |
5023-0285 | + | ||||
C 13 refrigerator connection cable with type 13 Swiss plug |
5023-0284 | + | ||||
C 13 refrigerator connection cable with CEE 7/7 European plug |
5023-0283 | + | ||||
Alarm system, battery-backed | ||||||
for maintaining temperature display, alarm messages, and communication |
8012-1910 | + | ||||
Analog output 4-20 mA | ||||||
for temperature values (output not adjustable) |
8012-1898 | + | ||||
Buck-boost converter | ||||||
automatic voltage compensation |
8012-1897 | + | ||||
Calibration certificate, expanded | ||||||
for temperature; for extending the measurement in center of chamber to include another test temperature |
8012-1126 | + | ||||
Calibration certificate, temperature | ||||||
temperature measurement incl. certificate, 20 measuring points at specified temperature |
8012-0925 | + | ||||
for temperature, measurement in center of chamber at specified temperature |
8012-0031 | + | ||||
Chamber rack with drawer, stainless steel | ||||||
for 6x4 standard boxes (50 mm), dimensions: H 340 x W 140 x D 560 mm |
6017-0051 | + | ||||
for 5x4 standard boxes (50 mm), dimensions: H 285 x W 140 x D 560 mm |
6017-0045 | + | ||||
for 6x4 standard boxes (50 mm) incl. boxes, dimensions: H 340 x W 140 x D 560 mm |
6017-0052 | + | ||||
for 5x4 standard boxes (50 mm) incl. boxes, dimensions: H 285 x W 140 x D 560 mm |
6017-0046 | + | ||||
Chamber rack, aluminum | ||||||
for 6x4 standard boxes (50 mm), dimensions: H 331 x W 139 x D 558 mm |
6017-0047 | + | ||||
for 5x4 standard boxes (50 mm), dimensions: H 276 x W 139 x D 558 mm |
6017-0041 | + | ||||
for 5x4 standard boxes (50 mm) incl. boxes, dimensions: H 276 x W 139 x D 558 mm |
6017-0042 | + | ||||
for 6x4 standard boxes (50 mm) incl. boxes, dimensions: H 331 x W 139 x D 558 mm |
6017-0048 | + | ||||
Chamber rack, stainless steel | ||||||
for 5x4 standard boxes (50 mm) incl. boxes, dimensions: H 276 x W 139 x D 558 mm |
6017-0044 | + | ||||
for 6x4 standard boxes (50 mm), dimensions: H 331 x W 139 x D 558 mm |
6017-0049 | + | ||||
for 6x4 standard boxes (50 mm) incl. boxes, dimensions: H 331 x W 139 x D 558 mm |
6017-0050 | + | ||||
for 5x4 standard boxes (50 mm), dimensions: H 276 x W 139 x D 558 mm |
6017-0043 | + | ||||
Compartment doors | ||||||
Foam-filled compartment doors with gasket |
8012-1893 | + | ||||
CO₂ backup cooling | ||||||
factory installed (allow for increased depth of UF V: 1085 mm), includes the option of a battery-backed alarm system |
8012-1891 | + | ||||
Cryoboxes | ||||||
set consisting of 36 cardboard boxes with sample dividers |
6017-0053 | + | ||||
Deicing kit | ||||||
consisting of de-icing tray, wiper and scraper |
8012-1900 | + | ||||
Door access system | ||||||
consisting of electromechanical door locking mechanism and electronic access control via NumPad |
8012-1899 | + | ||||
Door lock | ||||||
lockable door handle |
8012-1911 | + | ||||
pH-neutral detergent | ||||||
concentrated, for gentle remove of residual contaminants; 1 kg |
1002-0016 | + | ||||
Plugs | ||||||
CEE 7/7 |
+ | |||||
Qualification documents | ||||||
IQ/OQ documents – supporting documents for validation performed by customers, consisting of: IQ/OQ checklists incl. calibration guide and comprehensive unit documentation; parameters: temperature, CO₂, O₂, pressure, depending on unit |
7057-0001 | + | ||||
IQ/OQ documents – supporting documents for validation performed by customers, consisting of: IQ/OQ checklists incl. calibration guide and comprehensive unit documentation; parameters: temperature, CO₂, O₂, pressure, depending on unit |
7007-0001 | + | ||||
IQ/OQ/PQ documents – supporting documents for validation performed by customers, according to customer requirements, PQ section added to qualification folder IQ/OQ; parameters: temperature, CO₂, O₂ – or pressure, depending on unit |
7057-0005 | + | ||||
IQ/OQ/PQ documents – supporting documents for validation performed by customers, according to customer requirements, PQ section added to qualification folder IQ/OQ; parameters: temperature, CO₂, O₂ – or pressure, depending on unit |
7007-0005 | + | ||||
Shelf | ||||||
Incl. shelf supports |
8012-1901 | + | ||||
Shipping pallet | ||||||
with unloading ramp for installing unit without forklift |
8012-1906 | + | ||||
Switch cover | ||||||
Lockable main switch cover |
8012-1980 | + | ||||
WLAN kit | ||||||
The kit contains a client bridge that establishes a wireless connection between BINDER units and APT-COM4, LIMS, or customer-specific software via an Ethernet interface. It provides an alternative solution in situations where units need to be positioned in locations without an on-site Ethernet connection. In secured networks, installation and configuration must be performed by the customer’s IT service. |
8500-0164 | + |
Designation | Description | Art. No. | Bookmark | |||
---|---|---|---|---|---|---|
BRONZE 3-year maintenance contract |
Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts |
DL20-0710 | + | |||
Execution of IQ/OQ |
Execution of IQ/OQ in accordance with qualification folder |
DL41-0200 | + | |||
Execution of IQ/OQ/PQ |
Execution of IQ/OQ/PQ in accordance with qualification folder |
DL44-0500 | + | |||
GOLD 3-year maintenance contract |
Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts, testing of all key functions, replacement of wear parts, calibration of one test temperature specified by the user in the center of the usable space, including certificate |
DL20-0910 | + | |||
Installation of CO₂ backup cooling |
Installation of CO₂ backup cooling on unit |
DL02-8002 | + | |||
Maintenance |
One-off maintenance service in accordance with maintenance schedule. Visual inspection of mechanical and electrical components, testing of all key functions. Calibration of a test temperature specified by the user in center of usable space without certificate |
DL20-0200 | + | |||
SILVER 3-year maintenance contract |
Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts, testing of all key functions, calibration of one test temperature specified by the user in the center of the usable space, without certificate |
DL20-0810 | + | |||
Temperature calibration |
Extension of calibration of one (1) additional test temperature specified by the user in the center of the usable space, including certificate |
DL30-0102 | + | |||
Temperature calibration |
Calibration of one (1) test temperature specified by the user in center of chamber, including certificate |
DL30-0101 | + | |||
Temperature measurement, 20 measuring points |
Temperature measurement with 20 measuring points with a set value specified by the user, including certificate |
DL30-0620 | + | |||
Unit installation |
Connect the unit to the customer-side connections (electricity, water, wastewater, gas), basic functions check, brief operating instructions. (excl.: unpacking, setup, controller instructions, programming, installation work) |
DL10-0300 | + | |||
Unit instructions |
Instruction regarding operating principle and basic functions of the unit, operation of the control electronics including programming |
DL10-0700 | + |
Designation |
UFV500UL-240V¹ |
UFV500UL-120V¹ |
UFV500-230V-W¹ |
UFV500-230V¹ |
---|---|---|---|---|
Option model | Standard | Standard | Water cooling | Standard |
Order number | 9020-0353 | 9020-0351 | 9020-0349 | 9020-0347 |
Data | ||||
Serie | UF V | UF V | UF V | UF V |
Performance Data Temperature | ||||
Cooling down time from 22 °C to -80 °C [min] | 360 | 360 | 360 | 360 |
Temperature fluctuation at -80 °C [± K] | 1.5 | 1.5 | 1.5 | 1.5 |
Temperature range | -90…-40 | -90…-40 | -90…-40 | -90…-40 |
Temperature variation at -80 °C [± K] | 2.5 | 2.5 | 2.5 | 2.5 |
Warm-up time during power failure from -80 °C / -122 °F to -60 °C / -76 °F [min] | 230 | 230 | 230 | 230 |
Electrical data | ||||
Nominal power [kW] | 1.6 | 1.4 | 1.6 | 1.6 |
Phase (Nominal voltage) | 1~ | 1~ | 1~ | 1~ |
Power frequency [Hz] | 60 | 60 | 50 | 50 |
Rated Voltage [V] | 240 | 120 | 230 | 230 |
Unit fuse [A] | 10 | 13 | 10 | 10 |
Doors | ||||
Unit doors | 1 | 1 | 1 | 1 |
Housing dimensions not incl. fittings and connections | ||||
Depth net [mm] | 938 | 938 | 938 | 938 |
Height net [mm] | 1966 | 1966 | 1966 | 1966 |
Width net [mm] | 826 | 826 | 826 | 826 |
Internal Dimensions | ||||
Depth [mm] | 605 | 605 | 605 | 605 |
Height [mm] | 1300 | 1300 | 1300 | 1300 |
Width [mm] | 606 | 606 | 606 | 606 |
Measures | ||||
Interior volume [L] | 477 | 477 | 477 | 477 |
Net weight of the unit (empty) [kg] | 247 | 247 | 247 | 247 |
Permitted load [kg] | 200 | 200 | 200 | 200 |
Permitted load of individual compartment [kg] | 50 | 50 | 50 | 50 |
Wall clearance back [mm] | 100 | 100 | 100 | 100 |
Wall clearance sidewise [mm] | 250 | 250 | 250 | 250 |
Environment-specific data | ||||
Energy consumption at set-point -80 °C and ambient temperature = 21 °C [kWh/d] | 7.9 | 7.9 | 7.9 | 7.9 |
Sound-pressure level [dB(A)] | 47 | 47 | 47 | 47 |
Fixtures | ||||
Number of shelves (std./max.) | 3/13 | 3/13 | 3/13 | 3/13 |
Load-variants | ||||
Cryoboxes, 50 mm | 352 | 352 | 352 | 352 |
Freezer racks per compartment | 4 | 4 | 4 | 4 |
Performance Data Temperature | ||||
Cooling down time from 22 °C to -80 °C [min] | 360 | 360 | 360 | 360 |
Temperature fluctuation at -80 °C [± K] | 1.5 | 1.5 | 1.5 | 1.5 |
Temperature range | -90…-40 | -90…-40 | -90…-40 | -90…-40 |
Temperature variation at -80 °C [± K] | 2.5 | 2.5 | 2.5 | 2.5 |
Warm-up time during power failure from -80 °C / -122 °F to -60 °C / -76 °F [min] | 230 | 230 | 230 | 230 |
Electrical data | ||||
Nominal power [kW] | 1.6 | 1.4 | 1.6 | 1.6 |
Phase (Nominal voltage) | 1~ | 1~ | 1~ | 1~ |
Power frequency [Hz] | 60 | 60 | 50 | 50 |
Rated Voltage [V] | 240 | 120 | 230 | 230 |
Unit fuse [A] | 10 | 13 | 10 | 10 |
Doors | ||||
Unit doors | 1 | 1 | 1 | 1 |
Housing dimensions not incl. fittings and connections | ||||
Depth net [in] | 36.96 | 36.96 | 36.96 | 36.96 |
Height net [in] | 77.5 | 77.5 | 77.5 | 77.5 |
Width net [in] | 32.54 | 32.54 | 32.54 | 32.54 |
Internal Dimensions | ||||
Depth [in] | 23.84 | 23.84 | 23.84 | 23.84 |
Height [in] | 51.2 | 51.2 | 51.2 | 51.2 |
Width [in] | 23.88 | 23.88 | 23.88 | 23.88 |
Measures | ||||
Interior volume [cu.ft.] | 16.8 | 16.8 | 16.8 | 16.8 |
Net weight of the unit (empty) [lbs] | 545 | 545 | 545 | 545 |
Permitted load [lbs] | 441 | 441 | 441 | 441 |
Permitted load of individual compartment [lbs] | 110 | 110 | 110 | 110 |
Wall clearance back [in] | 3.94 | 3.94 | 3.94 | 3.94 |
Wall clearance sidewise [in] | 9.85 | 9.85 | 9.85 | 9.85 |
Environment-specific data | ||||
Energy consumption at set-point -80 °C and ambient temperature = 21 °C [kWh/d] | 7.9 | 7.9 | 7.9 | 7.9 |
Sound-pressure level [dB(A)] | 47 | 47 | 47 | 47 |
Fixtures | ||||
Number of shelves (std./max.) | 3/13 | 3/13 | 3/13 | 3/13 |
Load-variants | ||||
Cryoboxes, 50 mm | 352 | 352 | 352 | 352 |
Freezer racks per compartment | 4 | 4 | 4 | 4 |
Category | Title | File type / size | Download |
---|---|---|---|
Data Sheets |
UF V 500 |
PDF (207.74 kB ) | > |
UF V 500 US version with imperial values |
PDF (205.97 kB) | > | |
Operating Manuals |
UF V series |
PDF (8.36 MB) | > |
Technical Drawings |
Version UFV500-230V 9020-0347 |
PDF (602.44 kB) | > |
Case Studies |
Ultra low temperature freezers (UF V series) - BINDER freezers used to cool mRNA vaccines at vaccination centers Vaccination center in Germany |
PDF (115.60 kB) | > |
Case Studies |
Ultra low temperature freezers (UF V series) - THOR examines cosmetic products carefully under a microscope THOR Personal Care Sas |
PDF (762.50 kB) | > |
Case Studies |
Ultra low temperature freezers (UF V series) - BINDER freezers do their part in coronavirus vaccine research Professor Volker Thiel, Swiss virologist |
PDF (180.69 kB) | > |
White paper |
Validation and Qualification In the regulated environment |
PDF (393.27 kB) | > |
Brochures |
Ultralow temperature freezers UF V series |
PDF (1,006.91 kB) | > |
Brochures |
BINDER INDIVIDUAL Series production devices for special requirements |
PDF (713.75 kB) | > |