Just register your serial number – and enjoy the benefits.
There for you on-site – all thanks to the global BINDER Service organization.
What's new? Learn more in our news articles.
Simply subscribe and keep up to speed with the BINDER monthly newsletter.
Meet the specialists on simulation chambers. Where? Learn more here.
Do you have any questions or a specific request? Get in touch with us!
Do you have any questions? Here you can find the suitable contact person.
This is how you can find us!
Benefits
Important characteristics
Optional equipment
Details of the model
Select version
Technical data
The PDF data sheet contains technical data, options & accessories as well as services.
Downloads
Serie CKurzanleitung
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
CO2 -Inkubatoren Serien C | CB
Rated voltage | Option model | Version | Art. No. | Selection | Bookmark | |
---|---|---|---|---|---|---|
Model CB-S 260 | ||||||
200…230 V 1~ 50/60 Hz | ||||||
Standard |
CBS260-230V | 9640-0003 | + | |||
100…120 V 1~ 50/60 Hz | ||||||
Standard |
CBS260UL-120V | 9640-0004 | + |
Designation | Description | Art. No. | Bookmark | |||
---|---|---|---|---|---|---|
Access port with silicone plug | ||||||
left |
8612-0018 | + | ||||
right |
8612-0019 | + | ||||
back |
8612-0017 | + | ||||
Analog output 4-20 mA | ||||||
for temperature and CO₂ values (outputs not adjustable) |
8612-0016 | + | ||||
Base | ||||||
the base equipped with casters is used for the secure positioning and leveling of a BINDER CO₂ incubator |
9051-0044 | + | ||||
Calibration certificate, expanded | ||||||
for temperature; for extending the measurement in center of chamber to include another test temperature |
8012-1112 | + | ||||
Calibration certificate, temperature | ||||||
temperature measurement incl. certificate, 15- 18 measuring points at specified temperature |
8012-1570 | + | ||||
temperature measurement incl. certificate, 9 measuring points at specified temperature |
8012-1549 | + | ||||
temperature measurement incl. certificate and 27 measuring points at specified temperature |
8012-1591 | + | ||||
for temperature, measurement in center of chamber at specified temperature |
8012-1131 | + | ||||
Calibration certificate, temperature and CO₂ | ||||||
for temperature and CO₂, temperature measurement in center of chamber, CO₂ measurement performed using test gas at 37 °C and 5 % CO₂ |
8012-0228 | + | ||||
Cleaning kit | ||||||
for equipment maintenance and disinfection, consisting of pH-neutral detergent (1000 g, concentrate), spray disinfectant (500 ml, ready-to-use solution), lint-free cleansing tissues, protective gloves, and protective glasses |
8012-0503 | + | ||||
Door hinged on the left | ||||||
Unit door and standard glass inner door with door hinged on the left |
8612-0020 | + | ||||
Door lock | ||||||
lockable door handle |
8612-0021 | + | ||||
Gas cylinder connection set | ||||||
for CO₂, consisting of a gas tank pressure regulator with connection parts and 5-meter hose |
8012-0014 | + | ||||
Gas tank changer | ||||||
external, BINDER Gas Supply Service, for connecting 2 gas tanks (CO₂, N₂ or O₂), with audible and visual alarms, as well as zero-voltage alarm output |
8012-0408 | + | ||||
pH-neutral detergent | ||||||
concentrated, for gentle remove of residual contaminants; 1 kg |
1002-0016 | + | ||||
Qualification documents | ||||||
IQ/OQ documents – supporting documents for validation performed by customers, consisting of: IQ/OQ checklists incl. calibration guide and comprehensive unit documentation; parameters: temperature, CO₂, O₂, pressure, depending on unit |
7007-0001 | + | ||||
IQ/OQ/PQ documents – supporting documents for validation performed by customers, according to customer requirements, PQ section added to qualification folder IQ/OQ; parameters: temperature, CO₂, O₂ – or pressure, depending on unit |
7057-0005 | + | ||||
IQ/OQ/PQ documents – supporting documents for validation performed by customers, according to customer requirements, PQ section added to qualification folder IQ/OQ; parameters: temperature, CO₂, O₂ – or pressure, depending on unit |
7007-0005 | + | ||||
IQ/OQ documents – supporting documents for validation performed by customers, consisting of: IQ/OQ checklists incl. calibration guide and comprehensive unit documentation; parameters: temperature, CO₂, O₂, pressure, depending on unit |
7057-0001 | + | ||||
Rubber pads | ||||||
set anti-slip feet |
8012-0702 | + | ||||
Shaker „Universal“ | ||||||
Shaker and controller connected via ribbon cable, universally applicable, 100 – 240 V, 50/60 Hz |
8012-1771 | + | ||||
Shelf, perforated | ||||||
|
6004-0197 | + | ||||
Stacking adapter | ||||||
for the thermally isolated stacking of two BINDER CO₂ incubators |
9051-0039 | + | ||||
Stacking frame | ||||||
stable, vibration-free stacking frame on casters with stop brake for safe stacking of two CB series units |
9051-0041 | + | ||||
WLAN kit | ||||||
The kit contains a client bridge that establishes a wireless connection between BINDER units and APT-COM4, LIMS, or customer-specific software via an Ethernet interface. It provides an alternative solution in situations where units need to be positioned in locations without an on-site Ethernet connection. In secured networks, installation and configuration must be performed by the customer’s IT service. |
8500-0164 | + |
Designation | Description | Art. No. | Bookmark | |||
---|---|---|---|---|---|---|
BRONZE 3-year maintenance contract |
Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts |
DL20-0710 | + | |||
CO₂ calibration |
CO₂ calibration at a specified value, measurements are taken with analyzed test gas at 5%, including certificate |
DL30-0401 | + | |||
Execution of IQ/OQ |
Execution of IQ/OQ in accordance with qualification folder |
DL41-0200 | + | |||
Execution of IQ/OQ/PQ |
Execution of IQ/OQ/PQ in accordance with qualification folder |
DL44-0500 | + | |||
GOLD 3-year maintenance contract |
Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts, testing of all key functions, replacement of wear parts, calibration of one temperature and CO₂ value, including certificate |
DL20-0940 | + | |||
Maintenance |
One-off maintenance service in accordance with maintenance schedule. Visual inspection of mechanical and electrical components, testing of all key functions. Calibration of a test temperature specified by the user in center of usable space without certificate |
DL20-0400 | + | |||
SILVER 3-year maintenance contract |
Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts, testing of all key functions, calibration of one test temperature specified by the user in the center of the usable space, without certificate |
DL20-0820 | + | |||
Temperature calibration |
Extension of calibration of one (1) additional test temperature specified by the user in the center of the usable space, including certificate |
DL30-0102 | + | |||
Temperature calibration |
Calibration of one (1) test temperature specified by the user in center of chamber, including certificate |
DL30-0101 | + | |||
Temperature measurement, 18 measuring points |
Temperature measurement with 18 measuring points with a set value specified by the user, including certificate |
DL30-0118 | + | |||
Temperature measurement, 27 measuring points |
Temperature measurement with 27 measuring points with a set value specified by the user, including certificate |
DL30-0127 | + | |||
Temperature measurement, 9 measuring points |
Temperature measurement with 9 measuring points with a set value specified by the user, including certificate |
DL30-0109 | + | |||
Unit installation |
Connect the unit to the customer-side connections (electricity, water, wastewater, gas), basic functions check, brief operating instructions. (excl.: unpacking, setup, controller instructions, programming, installation work) |
DL10-0100 | + | |||
Unit instructions |
Instruction regarding operating principle and basic functions of the unit, operation of the control electronics including programming |
DL10-0500 | + | |||
Warranty extension from 2 to 3 years |
The warranty is extended by 1 year from the delivery date, wear parts are excluded |
DL50-0020 | + |
Designation |
CBS260UL-120V |
CBS260-230V |
---|---|---|
Option model | Standard | Standard |
Order number | 9640-0004 | 9640-0003 |
Data | ||
Serie | CB-S | CB-S |
Performance Data Temperature | ||
Recovery time after 30 seconds door open at 37 °C [min] | 8 | 8 |
Temperature fluctuation at 37 °C [± K] | 0.1 | 0.1 |
Temperature range +6 °C above ambient temperature to | 50 °C | 50 °C |
Temperature variation at 37 °C [± K] | 0.4 | 0.4 |
Performance Data Climate | ||
Humidity range | 90…95 | 90…95 |
CO₂-Data | ||
CO₂ measurement | IR | IR |
CO₂ range [Vol.-% CO₂] | 0…20 | 0…20 |
CO₂ Recovery time after 30 seconds door open at 5 Vol.-% CO₂ [min] | 5 | 5 |
Electrical data | ||
Nominal power [kW] | 1.5 | 1.5 |
Phase (Nominal voltage) | 1~ | 1~ |
Power frequency [Hz] | 50/60 | 50/60 |
Rated Voltage [V] | 100…120 | 200…230 |
Unit fuse [A] | 16 | 10 |
Doors | ||
Inner doors | 1 | 1 |
Unit doors | 1 | 1 |
Housing dimensions not incl. fittings and connections | ||
Depth net [mm] | 785 | 785 |
Height net [mm] | 1020 | 1020 |
Width net [mm] | 740 | 740 |
Internal Dimensions | ||
Depth [mm] | 575 | 575 |
Height [mm] | 750 | 750 |
Width [mm] | 620 | 620 |
Measures | ||
Interior volume [L] | 267 | 267 |
Load per rack [kg] | 10 | 10 |
Net weight of the unit (empty) [kg] | 122 | 122 |
Permitted load [kg] | 40 | 40 |
Wall clearance back [mm] | 100 | 100 |
Wall clearance sidewise [mm] | 50 | 50 |
Environment-specific data | ||
Energy consumption at 37 °C [Wh/h] | 55 | 55 |
Sound-pressure level [dB(A)] | 41 | 41 |
Fixtures | ||
Number of shelves (std./max.) | 2/8 | 2/8 |
Performance Data Temperature | ||
Recovery time after 30 seconds door open at 37 °C [min] | 8 | 8 |
Temperature fluctuation at 37 °C [± K] | 0.1 | 0.1 |
Temperature range +6 °C above ambient temperature to | 50 °C | 50 °C |
Temperature variation at 37 °C [± K] | 0.4 | 0.4 |
Performance Data Climate | ||
Humidity range | 90…95 | 90…95 |
CO₂-Data | ||
CO₂ measurement | IR | IR |
CO₂ range [Vol.-% CO₂] | 0…20 | 0…20 |
CO₂ Recovery time after 30 seconds door open at 5 Vol.-% CO₂ [min] | 5 | 5 |
Electrical data | ||
Nominal power [kW] | 1.5 | 1.5 |
Phase (Nominal voltage) | 1~ | 1~ |
Power frequency [Hz] | 50/60 | 50/60 |
Rated Voltage [V] | 100…120 | 200…230 |
Unit fuse [A] | 16 | 10 |
Doors | ||
Inner doors | 1 | 1 |
Unit doors | 1 | 1 |
Housing dimensions not incl. fittings and connections | ||
Depth net [in] | 30.93 | 30.93 |
Height net [in] | 40.2 | 40.2 |
Width net [in] | 29.16 | 29.16 |
Internal Dimensions | ||
Depth [in] | 22.65 | 22.65 |
Height [in] | 29.55 | 29.55 |
Width [in] | 24.43 | 24.43 |
Measures | ||
Interior volume [cu.ft.] | 9.4 | 9.4 |
Load per rack [lbs] | 22 | 22 |
Net weight of the unit (empty) [lbs] | 269 | 269 |
Permitted load [lbs] | 88 | 88 |
Wall clearance back [in] | 3.94 | 3.94 |
Wall clearance sidewise [in] | 1.97 | 1.97 |
Environment-specific data | ||
Energy consumption at 37 °C [Wh/h] | 55 | 55 |
Sound-pressure level [dB(A)] | 41 | 41 |
Fixtures | ||
Number of shelves (std./max.) | 2/8 | 2/8 |
Category | Title | File type / size | Download |
---|---|---|---|
Data Sheets |
CB-S 260 |
PDF (133.15 kB ) | > |
CB-S 260 US version with imperial values |
PDF (132.54 kB) | > | |
Operating Manuals |
CB-S series |
PDF (6.08 MB) | > |
Technical Drawings |
Version CB-S260-120V 9040-0192 |
PDF (236.70 kB) | > |
Technical Drawings |
Version CB-S260-230V 9040-0191 |
PDF (241.80 kB) | > |
Case Studies |
CO₂ incubator (CB series) - Stem cell research into healing musculoskeletal disorders University of Rochester School of Medicine and Dentistry |
PDF (224.21 kB) | > |
White paper |
"Good laboratory practice" What is behind all this? |
PDF (246.52 kB) | > |
White paper |
Good Laboratory Practice Your checklist for GLP-compliant research and development |
PDF (808.38 kB) | > |
White paper |
Cell cultivation: for and against particular technical solutions in co2 incubators The parameters to consider |
PDF (184.18 kB) | > |
White paper |
Cell cultivation without contamination Hot air sterilization and other means of contamination control in CO₂ incubators |
PDF (245.02 kB) | > |
White paper |
Validation and Qualification In the regulated environment |
PDF (393.27 kB) | > |
Options & Accessories |
Stacking options for BINDER CO₂ incubators C | CB series |
PDF (158.75 kB) | > |
Brochures |
BINDER INDIVIDUAL Series production devices for special requirements |
PDF (713.75 kB) | > |
Buyer´s Guide |
CO₂ incubators 6 things to consider when buying CO₂ incubators |
PDF (425.35 kB) | > |