Benefits
  • Safe and reproducible incubation conditions even at high environmental conditions
  • Hot air disinfection at 100°C
  • Energy efficient, environmentally friendly and secure

Configure your product with options and accessories and request it directly here.

Product description

The KT series combines outstanding performance with impressive energy efficiency and environmental friendliness. The refrigerated incubators of the KT series are state-of-the-art in application and protect the samples.

Important characteristics

  • Temperature range: 4 °C to 100 °C
  • APT.line™ preheating chamber technology
  • Adjustable fan speed
  • Electric refrigeration with Peltier module
  • Controller with time-segment and real-time programming
  • Display via LCD monitor
  • Input via pushbutton/rotary knob
  • Inner door made of tempered safety glass
  • 2 stainless steel racks
  • Units up to 115 liters are stackable
  • Class 3.1 independent temperature safety device (DIN 12880) with visual and audible temperature alarm
  • Computer interface: Ethernet
  • Data recording and USB interface

Technical specifications

Data
DesignationKT115-230VKT115UL-120V
Article Number9020-03139020-0314
Option model

Standard

Standard

Performance Data Temperature
Temperature range4...100 °C4...100 °C
Temperature uniformity at 37°C0.3 ± K0.3 ± K
Temperature fluctuation at 37°C0.1 ± K0.1 ± K
Max. heat compensation at 40°C100 W100 W
Recovery time after door was opened for 30 s at 37°C3 min3 min
Electrical data
Rated Voltage200...240 V100...120 V
Power frequency50/60 Hz50/60 Hz
Nominal power0,7 kW0,7 kW
Unit fuse10,0 A10,0 A
Phase (Nominal voltage)1~1~
Dimensions and weights
Interior volume4 cu.ft.4 cu.ft.
Net weight of the unit (empty)183 lbs183 lbs
Load per rack66 lbs66 lbs
Permitted load220 lbs220 lbs
Wall clearance back3,94 in3,94 in
Wall clearance sidewise9,45 in9,45 in
Housing dimensions not incl. fittings and connections
Width net33.86 in33.86 in
Height net28.15 in28.15 in
Depth net25.79 in25.79 in
Internal Dimensions
Interior width23.62 in23.62 in
Interior height17.91 in17.91 in
Interior depth13.98 in13.98 in
Inner doors11
Unit doors11
Environment-specific data
Sound-pressure level48 dB(A)48 dB(A)
Energy consumption at 37°C75 Wh/h75 Wh/h
Fixtures
Number of shelves (std./max.)2/62/6

Downloads

Refrigerated incubators

KT | KB ECO | KB | KB PRO series

pdf, 2.25 MB

LED light bar sets

Series KB | KB ECO | KT | KBF | KBF-S ECO | KMF

pdf, 405.05 KB

Cooling incubators (KB series) - Weleda tests anthroposophic medicine in line with ICH guidelines

Weleda AG

pdf, 789.37 KB

KT series

pdf, 9.2 MB

Data Sheet Model KT 115

pdf, 319.38 KB

Options, Accessories, Services

Sorry, no result could be found. Check the spelling or use a new search term.

Rubber pads

Set anti-slip feet

8012-2030

Rack

Stainless steel

8012-2049

Shelves

Rack - stainless steel

Shelf, perforated

Stainless steel

8012-2165

Shelf

Shelf, perforated - Stainless steel

Table on castors

Stable cart, casters with locking brakes, dimensions: W 1,000 x D 800 x H 780 mm

9051-0018

Tischwagen

stable cart, casters with locking brakes, dimensions: W 1,000 x D 800 x H 780 mm

Rack accessories

Fasteners (1 set of 4) for additional security of racks

8012-2280

Rack, reinforced

Stainless steel, with fasteners (1 set of 4)

8012-0828

Shelf

Rack, reinforced - stainless steel, with fasteners (1 set of 4)

LED light bars

Basic set consisting of 2 pieces, attachment material, control unit for max. 4 light strips, 100-240 V, 50/60 Hz. Basic set 300, length 30 cm

8012-1107

LED light strip sets

LED light bars - Basic set 300, length 30 cm, Basic set consisting of 2 pieces, attachment material, control unit for max. 4 light strips, 100-240 V, 50/60 Hz

LED light bars

Basic set consisting of 2 pieces, attachment material, control unit for max. 4 light strips, 100-240 V, 50/60 Hz. Basic set 500, length 50 cm

8012-1108

LED light strip sets

LED light bars - Basic set 500, length 50 cm, Basic set consisting of 2 pieces, attachment material, control unit for max. 4 light strips, 100-240 V, 50/60 Hz

LED light bars

Expansion set consisting of 2 pieces, attachment material: clips. For expanding the basic set of light bars. Expansion set 300, length 30 cm

8012-1716

LED light strip sets

LED light bars - Expansion set 300, length 30 cm, Expansion set consisting of 2 pieces, attachment material: clips. For expanding the basic set of light bars

LED light bars

Expansion set consisting of 2 pieces, attachment material: clips. For expanding the basic set of light bars. Expansion set 500, length 50 cm

8012-1717

LED light strip sets

LED light bars - Expansion set 500, length 50 cm, Expansion set consisting of 2 pieces, attachment material: clips. For expanding the basic set of light bars

APT-COM™ 4 BASIC-Edition

For simple logging and documentation requirements with up to 5 networked units.. version 4, BASIC edition

9053-0039

Multi Management Software APT-COM™

APT-COM™ 4 BASIC-Edition - for simple logging and documentation requirements with up to 5 networked units.

APT-COM™ 4 PROFESSIONAL-Edition

Convenient unit and user management built on the BASIC edition. Suitable for networking up to 100 units.. version 4, PROFESSIONAL edition

9053-0040

Multi Management Software APT-COM™

APT-COM™ 4 PROFESSIONAL-Edition - convenient unit and user management built on the BASIC edition. Suitable for networking up to 100 units.

APT-COM™ 4 GLP-Edition

For working under GLP-compliant conditions. Measured values are documented in a tamper-proof way in line with the requirements of FDA Regulation 21 CFR 11.. version 4, GLP edition

9053-0042

Multi Management Software APT-COM™

APT-COM™ 4 GLP-Edition - for working under GLP-compliant conditions. Measured values are documented in a tamper-proof way in line with the requirements of FDA Regulation 21 CFR 11.

pH-neutral detergent

Concentrated, for gentle remove of residual contaminants; 1 kg

8012-2250

1002-0016-Neutralreiniger-100x85_Web_670x515.jpg

pH-neutral detergent - concentrated, for gentle remove of residual contaminants; 1 kg

Qualification documents

IQ/OQ documents – supporting documents for validation performed by customers, consisting of: IQ/OQ checklists incl. calibration guide and comprehensive unit documentation; parameters: temperature, CO2, O2, pressure, depending on unit. Hard copy inside folder

7007-0001

Qualification documents

IQ/OQ documents – supporting documents for validation performed by customers, consisting of: IQ/OQ checklists incl. calibration guide and comprehensive unit documentation; parameters: temperature, CO2, O2, pressure, depending on unit. Digital in PDF format

7057-0001

Qualification documents

IQ/OQ/PQ documents – supporting documents for validation performed by customers, according to customer requirements, PQ section added to qualification folder IQ/OQ; parameters: temperature, CO2, O2 – or pressure, depending on unit. Hard copy inside folder

7007-0005

Qualification documents

IQ/OQ/PQ documents – supporting documents for validation performed by customers, according to customer requirements, PQ section added to qualification folder IQ/OQ; parameters: temperature, CO2, O2 – or pressure, depending on unit. Digital in PDF format

7057-0005

Sorry, no result could be found. Check the spelling or use a new search term.

Calibration certificate, expanded

For temperature; for extending the measurement in center of chamber to include another test temperature

8012-1122

Calibration certificate, temperature

For temperature, measurement in center of chamber at specified temperature

8012-1141

Access port with silicone plug

Top. 30 mm

8012-1152

Access port with silicone plug

Access port with silicone plug - 30 mm, top

Access port with silicone plug

Right. 30 mm

8012-1155

Access port with silicone plug

Access port with silicone plug - 30 mm, right

Access port with silicone plug

Left. 30 mm

8012-1158

Access port with silicone plug

Access port with silicone plug - 30 mm, left

Access port with silicone plug

Top. 50 mm

8012-1161

Access port with silicone plug

Access port with silicone plug - 50 mm, top

Access port with silicone plug

Right. 50 mm

8012-1163

Access port with silicone plug

Access port with silicone plug - 50 mm, right

Access port with silicone plug

Left. 50 mm

8012-1165

Access port with silicone plug

Access port with silicone plug - 50 mm, left

Access port with silicone plug

Top. 100 mm

8012-1168

Access port with silicone plug

Access port with silicone plug - 100 mm, top

Access port with silicone plug

Top. 10 mm

8012-1288

Access port with silicone plug

Access port with silicone plug - 10 mm, top

Access port with silicone plug

Right. 10 mm

8012-1289

Access port with silicone plug

Access port with silicone plug - 10 mm, right

Access port with silicone plug

Left. 10 mm

8012-1290

Access port with silicone plug

Access port with silicone plug - 10 mm, left

Calibration certificate, temperature

Temperature measurement incl. certificate, 9 measuring points at specified temperature

8012-1558

Calibration certificate, temperature

Temperature measurement incl. certificate, 15- 18 measuring points at specified temperature

8012-1579

Calibration certificate, temperature

Temperature measurement incl. certificate and 27 measuring points at specified temperature

8012-1600

Door lock

Lockable door handle

8012-1668

Door lock

Door lock - lockable door handle

Pt 100 temperature sensor

Additional flexible Pt 100, interior, for displaying the temperature on the unit display

8012-0993

Pt 100 temperature sensor

Pt 100 temperature sensor - additional flexible Pt 100, interior, for displaying the temperature on the unit display

Alarm output, zero-voltage

Accessible via 6-pin DIN socket (max. 24 V - 2.5 A)

8012-1001

Shelf, reinforced

Positioned at bottom level, max. load 45 kg, with additional attachment for operation of shaking device, stirring device or roller bottle system

8012-0817

Reinforced shelf racks

Shelf, reinforced - positioned at bottom level, max. load 45 kg, with additional attachment for operation of shaking device, stirring device or roller bottle system

Sorry, no result could be found. Check the spelling or use a new search term.

Temperature calibration

Extension of calibration of one (1) additional test temperature specified by the user in the center of the usable space, including certificate Travel to be quoted separate

DL30-0102

Services

Temperature calibration - Extension of calibration of one (1) additional test temperature specified by the user in the center of the usable space, including certificate Travel to be quoted separate.

Temperature measurement, 9 measuring points

Temperature measurement with 9 measuring points with a set value specified by the user, including certificate. Travel to be quoted separate.  A total of 3 shelvesare required

DL30-0109

Services

Temperature measurement, 9 measuring points - Temperature measurement with 9 measuring points with a set value specified by the user, including certificate. Travel to be quoted separate.  A total of 3 shelvesare required.

Temperature measurement, 18 measuring points

Temperature measurement with 18 measuring points with a set value specified by the user, including certificate. Travel to be quoted separate.  A total of 2 shelvesare required

DL30-0118

Services

Temperature measurement, 18 measuring points - Temperature measurement with 18 measuring points with a set value specified by the user, including certificate. Travel to be quoted separate.  A total of 2 shelvesare required.

Temperature measurement, 27 measuring points

Temperature measurement with 27 measuring points with a set value specified by the user, including certificate. Travel to be quoted separate.  A total of 3 shelvesare required

DL30-0127

Services

Temperature measurement, 27 measuring points - Temperature measurement with 27 measuring points with a set value specified by the user, including certificate. Travel to be quoted separate.  A total of 3 shelvesare required.

Execution of IQ/OQ

Execution of IQ/OQ in accordance with qualification folder. Travel to be quoted separate

DL41-0200

Services

Execution of IQ/OQ - Execution of IQ/OQ in accordance with qualification folder. Travel to be quoted separate.

Execution of IQ/OQ/PQ

Execution of IQ/OQ/PQ in accordance with qualification folder. Travel to be quoted separate

DL44-0500

Services

Execution of IQ/OQ/PQ - Execution of IQ/OQ/PQ in accordance with qualification folder. Travel to be quoted separate.

BRONZE 3-year maintenance contract

Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate. 10% Discount on Spare Parts and Labor for any additional Services needed Wear + tear parts to be purchased or billed to customer. Travel to be quoted as separate

DL20-0720

Services

BRONZE 3-year maintenance contract - Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate. 10% Discount on Spare Parts and Labor for any additional Services needed Wear + tear parts to be purchased or billed to customer. Travel to be quoted as separate.

Unit installation

Connect the unit to the customer-side connections (electricity, water, wastewater, gas), basic functions check, brief operating instructions. (excl.: unpacking, setup, controller instructions, programming, installation work) Travel to be quoted as separate

DL10-0100

Services

Unit installation - Connect the unit to the customer-side connections (electricity, water, wastewater, gas), basic functions check, brief operating instructions. (excl.: unpacking, setup, controller instructions, programming, installation work) Travel to be quoted as separate.

Unit instructions

Instruction regarding operating principle and basic functions of the unit, operation of the control electronics including programming. Travel to be quoted as separate Limited to 3 hours

DL10-0500

Services

Unit instructions - Instruction regarding operating principle and basic functions of the unit, operation of the control electronics including programming. Travel to be quoted as separate Limited to 3 hours.

1-year warranty extension

The warranty is extended by 1 year from the delivery date, wear parts are excluded

DL50-0010

Services

1-year warranty extension - The warranty is extended by 1 year from the delivery date, wear parts are excluded

SILVER 3-year maintenance contract

Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate 15% Discount on Spare Parts and Labor for any additional Services needed One additional courtesy visit per year can be used for service visit or operator training. Wear + tear parts to be purchased or billed to customer. Travel to be quoted separate

DL20-0845

Services

SILVER 3-year maintenance contract - Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate 15% Discount on Spare Parts and Labor for any additional Services needed One additional courtesy visit per year can be used for service visit or operator training. Wear + tear parts to be purchased or billed to customer. Travel to be quoted separate.

GOLD 3-year maintenance contract

Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate of Temperature. 25% Discount on Spare Parts and Labor for any additional Services needed. One additional courtesy visit per year can be used for service visit or operator. Wear + tear parts to be purchased or billed to customer. Travel to be quoted separate

DL20-0945

Services

GOLD 3-year maintenance contract - Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate of Temperature. 25% Discount on Spare Parts and Labor for any additional Services needed. One additional courtesy visit per year can be used for service visit or operator. Wear + tear parts to be purchased or billed to customer. Travel to be quoted separate.

Preventive maintenance 

One-off maintenance service in accordance with maintenance schedule. Visual inspection of mechanical and electrical components, testing of all key functions. Checking a test temperature specified by the user in center of usable space without certificate. Wear + tear parts need to be purchased or billed to customer. Travel to be quoted as separate

DL20-0604

Services

Preventive maintenance  - One-off maintenance service in accordance with maintenance schedule. Visual inspection of mechanical and electrical components, testing of all key functions. Checking a test temperature specified by the user in center of usable space without certificate. Wear + tear parts need to be purchased or billed to customer. Travel to be quoted as separate.

Temperature calibration

Calibration of one (1) test temperature specified by the user in center of chamber, including certificate Travel to be quoted separate

DL30-0135

Services

Temperature calibration - Calibration of one (1) test temperature specified by the user in center of chamber, including certificate Travel to be quoted separate.

Compare products: