Model KB 260 | Refrigerated incubators with a large temperature range
Benefits
- Assured: highly precise incubation conditions thanks to power reserves
- Reliable: failsafe operation over the long term thanks to proven compressor technology and interior made of stainless steel
- Smart: hot-air disinfection and easy programming of a second set temperature
- Economical: up to 40% lower energy consumption than the previous model thanks to modern inverter cooling technology
Product description
The powerful virtuoso in cooling incubators for microorganisms: KB units are able to incubate with exceptional precision even when fully loaded, feature a hot-air disinfection routine, and can be programmed for weekend operation with ease. The new KB unit consumes as much as 40% less energy than the previous model.
Important characteristics
- Temperature range: 0 °C to +70 °C
- Proven APT.line™ preheating chamber technology
- Up to 40% lower energy consumption compared to the previous model
- Energy-efficient cooling with modern inverter cooling unit
- Cooling with climate-neutral R-600a refrigerant
- Door heating to prevent condensation
- Sturdy housing design with HIT sandwich technology
- Interior made completely of stainless steel
- Inner doors made of metal oxide-coated safety glass
- Two racks made of stainless steel
- 80 mm x 45 mm access port with silicone plug
- Floor-standing units featuring sturdy twin casters with brakes at the front
- Simple programming of a second set temperature value
- Internal data logger, measured values can be read out in open format via USB
- Class 3.3 independent temperature safety device (DIN 12880) with visual and acoustic alarms
- Unit self-test for comprehensive status analysis
- Data interfaces: Ethernet, USB
Technical specifications
| Data | ||
| Article Number | 9020-0473 | 9020-0501 |
| Designation | KB260-230V | KB260UL-120V |
| Option model | Standard | Standard |
| Performance Data Temperature | ||
| Temperature range | 0...70 °C | 0...70 °C |
| Temperature uniformity at 37°C | 0.2 ± K | 0.2 ± K |
| Temperature fluctuation at 37°C | 0.1 ± K | 0.1 ± K |
| Max. heat compensation at 37°C | 410 W | 410 W |
| Recovery time after door was opened for 30 s at 37°C | 3 min | 3 min |
| Electrical data | ||
| Rated Voltage | 220...240 V | 120 V |
| Power frequency | 50/60 Hz | 50/60 Hz |
| Nominal power | 1,3 kW | 1,3 kW |
| Unit fuse | 16,0 A | 16,0 A |
| Phase (Nominal voltage) | 1~ | 1~ |
| Dimensions and weights | ||
| Interior volume | 9 cu.ft. | 9 cu.ft. |
| Net weight of the unit (empty) | 384 lbs | 384 lbs |
| Load per rack | 88 lbs | 88 lbs |
| Permitted load | 441 lbs | 441 lbs |
| Wall clearance back | 3,94 in | 3,94 in |
| Wall clearance sidewise | 7,09 in | 7,09 in |
| Housing dimensions not incl. fittings and connections | ||
| Width net | 36.61 in | 36.61 in |
| Height net | 54.96 in | 54.96 in |
| Depth net | 35.43 in | 35.43 in |
| Internal Dimensions | ||
| Interior width | 25.83 in | 25.83 in |
| Interior height | 27.36 in | 27.36 in |
| Interior depth | 22.64 in | 22.64 in |
| Inner doors | 1 | 1 |
| Unit doors | 1 | 1 |
| Environment-specific data | ||
| Sound-pressure level at 25°C | 50 dB(A) | 50 dB(A) |
| Energy consumption at 25°C | 130 Wh/h | 155 Wh/h |
| Energy consumption at 37°C | 140 Wh/h | 165 Wh/h |
| Fixtures | ||
| Number of shelves (std./max.) | 2/9 | 2/9 |
Options, accessories & services
Sorry, no result could be found. Check the spelling or use a new search term.
Door lock - lockable door handle
Door lock, electromechanical - can be opened with PIN code via controller
Access port with silicone plug - 100 mm, left
Access port with silicone plug - 100 mm, right
Access port with silicone plug - 100 mm, top
Access port with silicone plug - 30 mm, left
Access port with silicone plug - 50 mm, left
Access port with silicone plug - 30 mm, right
Access port with silicone plug - 50 mm, right
Access port with silicone plug - 50 mm, top
Access port with silicone plug - 30 mm, top
Sorry, no result could be found. Check the spelling or use a new search term.
BRONZE 3-year maintenance contract - Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts
SILVER 3-year maintenance contract - Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts, testing of all key functions, calibration of one test temperature specified by the user in the center of the usable space, without certificate
GOLD 3-year maintenance contract - Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts, testing of all key functions, replacement of wear parts, calibration of one test temperature specified by the user in the center of the usable space, including certificate
Preventive maintenance - One-off maintenance service in accordance with maintenance schedule. Visual inspection of mechanical and electrical components, testing of all key functions. Checking a test temperature specified by the user in center of usable space without certificate. Wear + tear parts need to be purchased or billed to customer. Travel to be quoted as separate.
Temperature calibration - Calibration of one (1) test temperature specified by the user in center of chamber, including certificate Travel to be quoted separate.
Temperature calibration - Extension of calibration of one (1) additional test temperature specified by the user in the center of the usable space, including certificate Travel to be quoted separate.
Temperature measurement, 9 measuring points - Temperature measurement with 9 measuring points with a set value specified by the user, including certificate. Travel to be quoted separate. A total of 3 shelvesare required.
Temperature measurement, 18 measuring points - Temperature measurement with 18 measuring points with a set value specified by the user, including certificate. Travel to be quoted separate. A total of 2 shelvesare required.
Temperature measurement, 27 measuring points - Temperature measurement with 27 measuring points with a set value specified by the user, including certificate. Travel to be quoted separate. A total of 3 shelvesare required.
Execution of IQ/OQ - Execution of IQ/OQ in accordance with qualification folder. Travel to be quoted separate.
Execution of IQ/OQ/PQ - Execution of IQ/OQ/PQ in accordance with qualification folder. Travel to be quoted separate.
1-year warranty extension - The warranty is extended by 1 year from the delivery date, wear parts are excluded
Unit installation - Connect the unit to the customer-side connections (electricity, water, wastewater, gas), basic functions check, brief operating instructions. (excl.: unpacking, setup, controller instructions, programming, installation work) Travel to be quoted as separate.
Unit instructions - Instruction regarding operating principle and basic functions of the unit, operation of the control electronics including programming. Travel to be quoted as separate Limited to 3 hours.
Sorry, no result could be found. Check the spelling or use a new search term.
LED light bars - Basic set 300, length 30 cm, Basic set consisting of 2 pieces, attachment material, control unit for max. 4 light strips, 100-240 V, 50/60 Hz
LED light bars - Basic set 500, length 50 cm, Basic set consisting of 2 pieces, attachment material, control unit for max. 4 light strips, 100-240 V, 50/60 Hz
LED light bars - Expansion set 300, length 30 cm, Expansion set consisting of 2 pieces, attachment material: clips. For expanding the basic set of light bars
LED light bars - Expansion set 500, length 50 cm, Expansion set consisting of 2 pieces, attachment material: clips. For expanding the basic set of light bars
pH-neutral detergent - concentrated, for gentle remove of residual contaminants; 1 kg
APT-COM™ 4 BASIC-Edition - for simple logging and documentation requirements with up to 5 networked units.
APT-COM™ 4 PROFESSIONAL-Edition - convenient unit and user management built on the BASIC edition. Suitable for networking up to 100 units.
APT-COM™ 4 GLP-Edition - for working under GLP-compliant conditions. Measured values are documented in a tamper-proof way in line with the requirements of FDA Regulation 21 CFR 11.