Model 3
Model 3
Model 3
Model 3
Dimensions
Dimensions
Temperature-environmental chart
Heavy duty shelves
Lighting with motion sensor
Conditioner postitioning at backside of chamber
Product image
Product image
Product image
Product image
Product image
Product image
Product image
Product image
Product image
Product image

Model WIC 3 | Walk-in-chambers for Stability Testing and Storage

Benefits
  • Stable and uniform environment
  • Fully complies with Pharma regulations (ICH)Equipment
  • Longevity - corrosion resistant
  • Ease of operation
  • Environmental friendly refrigerant with GWP value 547
  • Maintenance possible with the least possible disruption to the climate conditioning
  • Perfectly meets requirements in Pharma industry
  • 3 years warranty

Configure your product with options and accessories and request it directly here.

Product description

The walk-in-chambers offer a wide range of features and benefits to perfectly meet requirements in stability testing. Perfect test conditions are maintained in a wide range of temperature from 10°C to 50°C and relative humidity of 20% to 90% RH.

Important characteristics

  • Relative humidity accuracy of ± 2.5%
  • Temperature accuracy of ± 1.5°C
  • Duct work for proper distribution of air
  • Highly insulated room panels with U value of only 0,21 W/m2K
  • LED Lighting with motion detector
  • High quality room elements, made in Germany
  • Interior completely stainless steel
  • Exterior service accessibility
  • Room Elements: Galvanized sheet steel, polyester coated, white, similar to RAL 9010, interior surfaces in stainless steel,
    4 inch / 100 mm PU foam U value: 0,21W/m2K
  • Floor: Floor overlay is chrome-nickel steel, pattern-rolled 5WL
  • Surface load: 50.000 N/m2

Technical specifications

Data
Designation

WIC3-230V

WIC3-208V

WIC3C-208V

Article Number9800-00139800-00079800-0008
Option model

Standard

Standard

with conditioner on ceiling

Performance Data Climate
Temperature range with humidity10...50 °C10...50 °C10...50 °C
Humidity range20...90 % r.F.20...90 % r.F.20...90 % r.F.
Temperature uniformity at 25°C and 60% RH1.5 ± K1.5 ± K1.5 ± K
Temperature uniformity at 40°C and 75% RH1.5 ± K1.5 ± K1.5 ± K
Temperature fluctuation at 25°C and 60% RH0.5 ± K0.5 ± K0.5 ± K
Temperature fluctuation at 40°C and 75% RH0.5 ± K0.5 ± K0.5 ± K
Humidity fluctuation at 25°C and 60% RH2.52.52.5
Humidity fluctuation at 40°C and 75% RH2.52.52.5
Electrical data
Rated Voltage230 V208...230 V208...230 V
Power frequency50 Hz60 Hz60 Hz
Nominal power2,7 kW2,7 kW2,7 kW
Unit fuse20 A20 A20 A
Phase (Nominal voltage)1~1~1~
Measures
Net weight of the unit (empty)1186 kg1186 kg1186 kg
Internal Dimensions
Interior width2400 mm2400 mm2400 mm
Interior height2270 mm2270 mm2270 mm
Interior depth4700 mm4700 mm4700 mm
Environment-specific data
Energy consumption at 40°C and 75% RH1150 Wh/h1150 Wh/h1150 Wh/h

Downloads

Environmental Walk-in chambers

pdf, 589.46 KB

Suggested products

WIC 1

Model WIC 1 | Walk-in-chambers for Stability Testing and Storage

  • Relative humidity accuracy of ± 2.5%
  • Temperature accuracy of ± 1.5°C
  • LED Lighting with motion detector
  • Interior completely stainless steel
To product
WIC 2

Model WIC 2 | Walk-in-chambers for Stability Testing and Storage

  • Relative humidity accuracy of ± 2.5%
  • Temperature accuracy of ± 1.5°C
  • LED Lighting with motion detector
  • Interior completely stainless steel
To product

Compare products:

Or add another product.