Model VDL 56 | Vacuum drying chambers for flammable solvents
Benefits
- Fast, gentle drying
- Optimum heat transfer through large thermal conducting plates
- Safe working thanks to ATEX-compliant safety concept
- Also option of modular complete system with vacuum pump and pump chamber
Product description
BINDER VDL series safety vacuum drying chambers ensure maximum safety when drying organic solvents. Explosion-protected unit with classification according to ATEX directive 2014/34/EU: EX II 2/3/- G IIB T3 Gb/Gc/- X.
Important characteristics
- Temperature range: +9°C above ambient temperature to +110 °C
- ATEX conformity for units: EX II 2/3/- G IIB T3 Gb/Gc/- X
- Intuitive touchscreen controller with graphical pressure and temperature display
- Program-controlled drying monitoring with automatic ventilation at end of process
- Internal data logger, measured values can be read out in open format via USB
- Pressure control device for heating activated from < 100 mbar
- 2 aluminum expansion racks, can be custom-positioned
- Universal connection for ventilation with ambient air or inert gas
- Universal access port DN 16 - for the introduction of external measuring devices
- Shatterproof, spring-mounted safety glass panel
- Large viewing window
- Computer interface: Ethernet
Technical specifications
| Data | ||
| Designation | VDL056-230V | VDL056-120V |
| Article Number | 9630-0010 | 9630-0014 |
| Option model | Standard | Standard |
| Performance Data Temperature | ||
| Temperature range | +9 °C above ambient temperature to 110 °C | +9 °C above ambient temperature to 110 °C |
| Temperature uniformity at 100°C | 1.2 ± K | 1.2 ± K |
| Temperature fluctuation at 100°C | 0.1 ± K | 0.1 ± K |
| Heating up time to 100°C | 140 min | 140 min |
| Vacuum Data | ||
| Leak rate | 0,01 bar/h | 0,01 bar/h |
| Pressure fluctuation over time at 50 mbar | 1 ± mbar | 1 ± mbar |
| Pressure fluctuation over time at 400 mbar | 70 ± mbar | 70 ± mbar |
| Electrical data | ||
| Rated Voltage | 200...230 V | 100...120 V |
| Power frequency | 50/60 Hz | 50/60 Hz |
| Nominal power | 1,4 kW | 1,4 kW |
| Unit fuse | 8,0 A | 16,0 A |
| Phase (Nominal voltage) | 1~ | 1~ |
| Connections | ||
| Vacuum connection with small flange | 16 DN mm | 16 DN mm |
| Measuring access port with small flange | 16 DN mm | 16 DN mm |
| Dimensions and weights | ||
| Interior volume | 2 cu.ft. | 2 cu.ft. |
| Net weight of the unit (empty) | 229 lbs | 229 lbs |
| Load per rack | 44 lbs | 44 lbs |
| Permitted load | 132 lbs | 132 lbs |
| Wall clearance back | 3,94 in | 3,94 in |
| Wall clearance sidewise | 2,76 in | 2,76 in |
| Housing dimensions not incl. fittings and connections | ||
| Width net | 25.12 in | 25.12 in |
| Height net | 32.09 in | 32.09 in |
| Depth net | 18.15 in | 18.15 in |
| Internal Dimensions | ||
| Interior width | 15.75 in | 15.75 in |
| Interior height | 15.75 in | 15.75 in |
| Interior depth | 13.5 in | 13.5 in |
| Unit doors | 1 | 1 |
| Environment-specific data | ||
| Sound-pressure level | 40 dB(A) | 40 dB(A) |
| Energy consumption at 100°C | 180 Wh/h | 180 Wh/h |
| Fixtures | ||
| Number of shelves (std./max.) | 2/5 | 2/5 |
Downloads
Options, Accessories, Services
Sorry, no result could be found. Check the spelling or use a new search term.
Expansion racks - aluminum
Expansion racks - stainless steel
Vacuum pump VP5 EX - ATEX chemical membrane pump with nominal pumping speed 1.9 m³/h, final pressure 12 mbar, 230V/50Hz.ATEX conformity: maximum permissible pressure at inlet and 1.1 suction chamber (pumped gases): II 2G Ex h IIC T3 Gb X;exterior with inert gas flushing: II 2G Ex h IIB T4 Gb X;exterior without inert gas flushing: II 3G Ex h IIB T4 Gc X motor: II 2G Ex db IIB T4 Gb
Pump chamber VDL 56 with vacuum pump VP5 EX - 230 V / 50-60 Hz option model, Pump chamber for installation of vacuum pumps. Including ATEX chemical membrane pump with nominal pumping speed 1.9 m³/h, final pressure 12 mbar, 230V/50Hz.ATEX conformity: suction chamber (pumped gases): II 2G Ex h IIC T3 Gb X; exterior with inert gas flushing: II 2G Ex h IIB T4 Gb X; exterior without inert gas flushing: II 3G Ex h IIB T4 Gc X motor: II 2G Ex db IIB T4 Gb
APT-COM™ 4 BASIC-Edition - for simple logging and documentation requirements with up to 5 networked units.
APT-COM™ 4 PROFESSIONAL-Edition - convenient unit and user management built on the BASIC edition. Suitable for networking up to 100 units.
APT-COM™ 4 GLP-Edition - for working under GLP-compliant conditions. Measured values are documented in a tamper-proof way in line with the requirements of FDA Regulation 21 CFR 11.
pH-neutral detergent - concentrated, for gentle remove of residual contaminants; 1 kg
Sorry, no result could be found. Check the spelling or use a new search term.
Temperature measurement of the specimen - with flexible Pt 100 sensor and digital specimen temperature display
Door lock - lockable door handle
Additional universal ventilation - Additional universal connection for ventilation with ambient air or inert gas. Flow limiter thread (RP"), and connection with 3/8" male thread.
Analog output 4-20 mA - for temperature and pressure values (output not adjustable)
Expansion racks - stainless steel expansion rack instead of standard aluminum expansion rack, incl. calibration
Door gasket - made of FKM, silicone-free
Sorry, no result could be found. Check the spelling or use a new search term.
BRONZE 3-year maintenance contract - Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate. 10% Discount on Spare Parts and Labor for any additional Services needed Wear + tear parts to be purchased or billed to customer. Travel to be quoted as separate.
Unit instructions - Instruction regarding operating principle and basic functions of the unit, operation of the control electronics including programming. Travel to be quoted as separate Limited to 3 hours.
Temperature calibration - Extension of calibration of one (1) additional test temperature specified by the user in the center of the usable space, including certificate Travel to be quoted separate.
Temperature measurement, 9 measuring points - Temperature measurement with 9 measuring points with a set value specified by the user, including certificate. Travel to be quoted separate. A total of 3 shelvesare required.
Execution of IQ/OQ/PQ - Execution of IQ/OQ/PQ in accordance with qualification folder. Travel to be quoted separate.
1-year warranty extension - The warranty is extended by 1 year from the delivery date, wear parts are excluded
Unit installation - Connect the unit to the customer-side connections (electricity, water, wastewater, gas), basic functions check, brief operating instructions. (excl.: unpacking, setup, controller instructions, programming, installation work) Travel to be quoted as separate.
Temperature measurement, 15 measuring points - Temperature measurement with 15 measuring points with a set value specified by the user, including certificate. Travel to be quoted separate.
Pressure calibration - Digital pressure display calibration at a specified test pressure of 20–900 mbar, including certificate. Travel to be quoted separate.
Pressure calibration - Expansion – Additional Digital pressure display calibration at a specified test pressure of 20–900 mbar, including certificate. Travel to be quoted separate.
Execution of IQ/OQ - Execution of IQ/OQ in accordance with qualification folder. Travel to be quoted separate.
VAP 5 vacuum pump maintenance - Maintenance service of the VAP 5 vacuum pump according to the maintenance schedule, visual inspection, replacement of the diaphragms, O-rings and seals, (Service Kit 8500-0160 included in the scope of services) as well as final functional test. Travel to be quoted as separate.
Preventive maintenance - One-off maintenance service in accordance with maintenance schedule. Visual inspection of mechanical and electrical components, testing of all key functions. Checking a test temperature specified by the user in center of usable space without certificate. Wear + tear parts need to be purchased or billed to customer. Travel to be quoted as separate.
SILVER 3-year maintenance contract - Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate 15% Discount on Spare Parts and Labor for any additional Services needed One additional courtesy visit per year can be used for service visit or operator training. Wear + tear parts to be purchased or billed to customer. Travel to be quoted separate.
GOLD 3-year maintenance contract - Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate of Temperature. 25% Discount on Spare Parts and Labor for any additional Services needed. One additional courtesy visit per year can be used for service visit or operator. Wear + tear parts to be purchased or billed to customer. Travel to be quoted separate.
Temperature calibration - Calibration of one (1) test temperature specified by the user in center of chamber, including certificate Travel to be quoted separate.