Model FDL 115 | Safety drying chambers for limited quantities of solvent
Benefits
- Safety concept meets the DIN EN 1539-2010-08 standard
- Short drying time with high temperature accuracy and defined ventilation
- Silicone free and dust-free inner chamber
- Replaceable fresh air cartridges are easy to change and ensure constant fresh air quality
Product description
The BINDER FDL 115 with silicone and dust-free inner chamber, as well as symmetric airflow dries specimens containing solvents and thus this safety drying oven meets all EN 1539 requirements.
Important characteristics
- Temperature range: +10°C above ambient temperature to +300 °C
- APT.line™ preheating chamber technology
- Controller with time-segment and real-time programming
- 2 chrome-plated racks
- Fresh-air monitoring with audible and visual alarm and automatic deactivation of heating
- Replaceable filter cartridge, Class M6
- Class 2 independent adjustable temperature safety device (DIN 12880) with visual alarm
- Computer interface: RS 422
- Standard door gasket made from solvent-resistant FKM for use at up to 200 °C
- Optional door gasket made from silicone with limited solvent resistance for use at up to 300 °C
Technical specifications
| Data | |
| Designation | FDL115-230V |
| Article Number | 9010-0292 |
| Option model | Standard |
| Performance Data Temperature | |
| Temperature range | +10 °C above ambient temperature to 300 °C |
| Temperature uniformity at 150°C | 2.5 ± K |
| Temperature fluctuation at 150°C | 0.8 ± K |
| Heating up time to 150°C | 20 min |
| Recovery time after door was opened for 30 s at 150°C | 12 min |
| Air change data | |
| Air circulation (approx.) | 20 x/min |
| Volumetric flow rate of exhaust air acc. to EN 1539 at 50 °C | 400 ca. L/min |
| Solvent quantity | |
| Highest permitted solvent quantity (at T-180°C, M-100g/mol, U-40g/m3, K=0,5) | 4,67 g |
| Electrical data | |
| Rated Voltage | 230 V |
| Power frequency | 50/60 Hz |
| Nominal power | 2,9 kW |
| Phase (Nominal voltage) | 1~ |
| Dimensions and weights | |
| Interior volume | 4 cu.ft. |
| Net weight of the unit (empty) | 198 lbs |
| Load per rack | 66 lbs |
| Permitted load | 132 lbs |
| Wall clearance back | 6,3 in |
| Wall clearance sidewise | 3,94 in |
| Housing dimensions not incl. fittings and connections | |
| Width net | 32.68 in |
| Height net | 31.69 in |
| Depth net | 26.97 in |
| Internal Dimensions | |
| Interior width | 23.62 in |
| Interior height | 17.13 in |
| Interior depth | 17.13 in |
| Unit doors | 1 |
| Environment-specific data | |
| Sound-pressure level | 57 dB(A) |
| Energy consumption at 150°C | 1,200 Wh/h |
| Fixtures | |
| Number of shelves (std./max.) | 2/5 |
Options, accessories & services
Sorry, no result could be found. Check the spelling or use a new search term.
Sorry, no result could be found. Check the spelling or use a new search term.
Temperature measurement, 9 measuring points - Temperature measurement with 9 measuring points with a set value specified by the user, including certificate. Travel to be quoted separate. A total of 3 shelvesare required.
Temperature measurement, 18 measuring points - Temperature measurement with 18 measuring points with a set value specified by the user, including certificate. Travel to be quoted separate. A total of 2 shelvesare required.
Temperature measurement, 27 measuring points - Temperature measurement with 27 measuring points with a set value specified by the user, including certificate. Travel to be quoted separate. A total of 3 shelvesare required.
Measurement of air exchange rate - including certificate (in accordance with ASTM D5374)
Execution of IQ/OQ - Execution of IQ/OQ in accordance with qualification folder. Travel to be quoted separate.
Execution of IQ/OQ/PQ - Execution of IQ/OQ/PQ in accordance with qualification folder. Travel to be quoted separate.
Temperature calibration - Extension of calibration of one (1) additional test temperature specified by the user in the center of the usable space, including certificate Travel to be quoted separate.
1-year warranty extension - The warranty is extended by 1 year from the delivery date, wear parts are excluded
SILVER 3-year maintenance contract - Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate 15% Discount on Spare Parts and Labor for any additional Services needed One additional courtesy visit per year can be used for service visit or operator training. Wear + tear parts to be purchased or billed to customer. Travel to be quoted separate.
BRONZE 3-year maintenance contract - Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate. 10% Discount on Spare Parts and Labor for any additional Services needed Wear + tear parts to be purchased or billed to customer. Travel to be quoted as separate.
Preventive maintenance - One-off maintenance service in accordance with maintenance schedule. Visual inspection of mechanical and electrical components, testing of all key functions. Checking a test temperature specified by the user in center of usable space without certificate. Wear + tear parts need to be purchased or billed to customer. Travel to be quoted as separate.
Temperature calibration - Calibration of one (1) test temperature specified by the user in center of chamber, including certificate Travel to be quoted separate.
Sorry, no result could be found. Check the spelling or use a new search term.
stable cart, casters with locking brakes, dimensions: W 1,000 x D 800 x H 780 mm
Rack - stainless steel
Shelf, perforated - Stainless steel
pH-neutral detergent - concentrated, for gentle remove of residual contaminants; 1 kg
APT-COM™ 4 BASIC-Edition - for simple logging and documentation requirements with up to 5 networked units.
APT-COM™ 4 PROFESSIONAL-Edition - convenient unit and user management built on the BASIC edition. Suitable for networking up to 100 units.
APT-COM™ 4 GLP-Edition - for working under GLP-compliant conditions. Measured values are documented in a tamper-proof way in line with the requirements of FDA Regulation 21 CFR 11.