Model 56
Model 56
Model 56
Model 56
Dimensions
Product image
Product image
Product image
Product image
Product image

Model M 56 | Drying and heating chambers with forced convection and advanced program functions

Benefits
  • Uniform drying conditions thanks to APT.line™ technology
  • Identical test conditions throughout the chamber interior independent of sample size and quantity
  • Outstanding thermal insulation saves operation costs
  • Advanced programming options

Configure your product with options and accessories and request it directly here.

Product description

With a maximum of +300 °C and various programming options the M series material test chambers are ideal for material and aging tests. With a high air flow, the powerful fans ensure rapid heating.

Important characteristics

  • Temperature range: +23°C above ambient temperature to +300°C
  • High temperature accuracy thanks to APT.line™ technology with increased heating output
  • Reinforced fan with adjustable speed
  • Electromechanical control of the exhaust air flap
  • Intuitive touchscreen controller with time-segment and real-time programming
  • 2 chrome-plated racks
  • Class 2 independent adjustable temperature safety device (DIN 12880) and class 3.1 independent temperature safety device (DIN 12880) with visual/acoustic alarm available for selection on the controller
  • Failsafe function – backup sensor Pt 100
  • Computer interface: Ethernet
  • Internal data logger, measured values can be read out in open format via USB

Technical specifications

Data
Designation

M056-230V

Article Number9010-0371
Option model

Standard

Performance Data Temperature
Temperature range+23 °C above ambient temperature to 300 °C
Temperature uniformity at 150°C1.4 ± K
Temperature fluctuation at 150°C0.2 ± K
Heating up time to 150°C9 min
Recovery time after door was opened for 30 s at 150°C4 min
Air change data
Air change rate at 100°C175 x/h
Electrical data
Rated Voltage230 V
Power frequency50/60 Hz
Nominal power2 kW
Unit fuse10,0 A
Phase (Nominal voltage)1~
Dimensions and weights
Interior volume2 cu.ft.
Net weight of the unit (empty)95 lbs
Load per rack66 lbs
Permitted load154 lbs
Wall clearance back6,3 in
Wall clearance sidewise3,94 in
Housing dimensions not incl. fittings and connections
Width net22.05 in
Height net24.49 in
Depth net23.46 in
Internal Dimensions
Interior width15.75 in
Interior height17.32 in
Interior depth13.19 in
Unit doors1
Environment-specific data
Sound-pressure level46 dB(A)
Energy consumption at 100°C210 Wh/h
Energy consumption at 150°C330 Wh/h
Fixtures
Number of shelves (std./max.)2/4

Downloads

Drying and heating chambers

Series FP | M

pdf, 168.24 KB

Series M Avantgarde.Line

pdf, 11 MB

Data Sheet Model M 56

pdf, 458.81 KB

Options, Accessories, Services

Sorry, no result could be found. Check the spelling or use a new search term.

Rubber pads

Set anti-slip feet

8012-2030

Rack

Max. load per rack 30 kg. chrome plated

8012-2038

Shelves

Rack - chrome plated

Rack

Max. load per rack 30 kg. stainless steel

8012-2085

Shelves

Rack - stainless steel

Shelf, perforated

Max. load per rack 30 kg. Stainless steel

8012-2175

Shelf

Shelf, perforated - Stainless steel

Table on castors

Stable cart, casters with locking brakes, dimensions: W 1,000 x D 800 x H 780 mm

9051-0018

Tischwagen

stable cart, casters with locking brakes, dimensions: W 1,000 x D 800 x H 780 mm

APT-COM™ 4 BASIC-Edition

For simple logging and documentation requirements with up to 5 networked units.. version 4, BASIC edition

9053-0039

Multi Management Software APT-COM™

APT-COM™ 4 BASIC-Edition - for simple logging and documentation requirements with up to 5 networked units.

APT-COM™ 4 PROFESSIONAL-Edition

Convenient unit and user management built on the BASIC edition. Suitable for networking up to 100 units.. version 4, PROFESSIONAL edition

9053-0040

Multi Management Software APT-COM™

APT-COM™ 4 PROFESSIONAL-Edition - convenient unit and user management built on the BASIC edition. Suitable for networking up to 100 units.

APT-COM™ 4 GLP-Edition

For working under GLP-compliant conditions. Measured values are documented in a tamper-proof way in line with the requirements of FDA Regulation 21 CFR 11.. version 4, GLP edition

9053-0042

Multi Management Software APT-COM™

APT-COM™ 4 GLP-Edition - for working under GLP-compliant conditions. Measured values are documented in a tamper-proof way in line with the requirements of FDA Regulation 21 CFR 11.

pH-neutral detergent

Concentrated, for gentle remove of residual contaminants; 1 kg

8012-2250

1002-0016-Neutralreiniger-100x85_Web_670x515.jpg

pH-neutral detergent - concentrated, for gentle remove of residual contaminants; 1 kg

Qualification documents

IQ/OQ documents – supporting documents for validation performed by customers, consisting of: IQ/OQ checklists incl. calibration guide and comprehensive unit documentation; parameters: temperature, CO2, O2, pressure, depending on unit. Hard copy inside folder

7007-0001

Qualification documents

IQ/OQ documents – supporting documents for validation performed by customers, consisting of: IQ/OQ checklists incl. calibration guide and comprehensive unit documentation; parameters: temperature, CO2, O2, pressure, depending on unit. Digital in PDF format

7057-0001

Qualification documents

IQ/OQ/PQ documents – supporting documents for validation performed by customers, according to customer requirements, PQ section added to qualification folder IQ/OQ; parameters: temperature, CO2, O2 – or pressure, depending on unit. Hard copy inside folder

7007-0005

Qualification documents

IQ/OQ/PQ documents – supporting documents for validation performed by customers, according to customer requirements, PQ section added to qualification folder IQ/OQ; parameters: temperature, CO2, O2 – or pressure, depending on unit. Digital in PDF format

7057-0005

Sorry, no result could be found. Check the spelling or use a new search term.

Gas-tight option model

Incl. additional measures for the greatest possible impermeability to gas; not in conjunction with access port or interior lighting option  

8012-2308

HEPA air filter

On fresh air supply for unit; filter classification H14 (acc. to. EN 1822-1:2009, > 99.995% at 0.3 µm); not in conjunction with reinforced heating output, reinforced fan

8012-2311

HEPA air filter

HEPA air filter - On fresh air supply for unit; filter classification H14 (acc. to. EN 1822-1:2009, > 99.995% at 0.3 µm); not in conjunction with reinforced heating output, reinforced fan

Door gasket

Made of FKM, silicone-free

8012-2331

Door lock

Lockable door handle

8012-2335

Door lock

Door lock - lockable door handle

Inert gas connection

With gas inlet and outlet, Ø 10 mm, incl. additional measures for the greatest possible impermeability to gas; not in conjunction with access port or interior lighting option

8012-2315

Inner chamber, reinforced

Max. total load 85 kg

8012-2320

Analog output 4-20 mA

For temperature values (output not adjustable)

8012-2295

Access port with silicone plug

Left. 10 mm

8012-2296

Access port with silicone plug

Access port with silicone plug - 10 mm, left

Access port with silicone plug

Top. 10 mm

8012-2297

Access port with silicone plug

Access port with silicone plug - 10 mm, top

Access port with silicone plug

Right. 10 mm

8012-2298

Access port with silicone plug

Access port with silicone plug - 10 mm, right

Access port with silicone plug

Top. 100 mm

8012-2300

Access port with silicone plug

Access port with silicone plug - 100 mm, top

Access port with silicone plug

Left. 30 mm

8012-2302

Access port with silicone plug

Access port with silicone plug - 30 mm, left

Access port with silicone plug

Top. 30 mm

8012-2303

Access port with silicone plug

Access port with silicone plug - 30 mm, top

Access port with silicone plug

Right. 30 mm

8012-2304

Access port with silicone plug

Access port with silicone plug - 30 mm, right

Access port with silicone plug

Left. 50 mm

8012-2305

Access port with silicone plug

Access port with silicone plug - 50 mm, left

Access port with silicone plug

Top. 50 mm

8012-2306

Access port with silicone plug

Access port with silicone plug - 50 mm, top

Access port with silicone plug

Right. 50 mm

8012-2307

Access port with silicone plug

Access port with silicone plug - 50 mm, right

Calibration certificate, temperature

For temperature, measurement in center of chamber at specified temperature

8012-2324

Calibration certificate, temperature

Temperature measurement incl. certificate, 15- 18 measuring points at specified temperature

8012-2325

Calibration certificate, temperature

Temperature measurement incl. certificate and 27 measuring points at specified temperature

8012-2326

Calibration certificate, temperature

Temperature measurement incl. certificate, 9 measuring points at specified temperature

8012-2327

Calibration certificate, expanded

For temperature; for extending the measurement in center of chamber to include another test temperature

8012-2328

Measurement of air exchange rate

In accordance with ASTM D5374, definition and protocol according to ambient temperature

8012-2329

Pt 100 temperature sensor

Additional flexible Pt 100, interior, for displaying the temperature on the unit display

8012-2330

Pt 100 temperature sensor

Pt 100 temperature sensor - additional flexible Pt 100, interior, for displaying the temperature on the unit display

Specimen temperature control

With additional specimen temperature sensor. Standard function 2 zero-voltage relay contacts not applicable

8012-2343

Temperature measurement of the specimen with Pt 100 sensor

Specimen temperature control - With additional specimen temperature sensor. Standard function 2 zero-voltage relay contacts not applicable.

Interior lighting

With 27 W light bulb. 230/240 V option model

8012-2318

Sorry, no result could be found. Check the spelling or use a new search term.

Temperature calibration

Extension of calibration of one (1) additional test temperature specified by the user in the center of the usable space, including certificate Travel to be quoted separate

DL30-0102

Services

Temperature calibration - Extension of calibration of one (1) additional test temperature specified by the user in the center of the usable space, including certificate Travel to be quoted separate.

Temperature measurement, 9 measuring points

Temperature measurement with 9 measuring points with a set value specified by the user, including certificate. Travel to be quoted separate.  A total of 3 shelvesare required

DL30-0109

Services

Temperature measurement, 9 measuring points - Temperature measurement with 9 measuring points with a set value specified by the user, including certificate. Travel to be quoted separate.  A total of 3 shelvesare required.

Temperature measurement, 18 measuring points

Temperature measurement with 18 measuring points with a set value specified by the user, including certificate. Travel to be quoted separate.  A total of 2 shelvesare required

DL30-0118

Services

Temperature measurement, 18 measuring points - Temperature measurement with 18 measuring points with a set value specified by the user, including certificate. Travel to be quoted separate.  A total of 2 shelvesare required.

Temperature measurement, 27 measuring points

Temperature measurement with 27 measuring points with a set value specified by the user, including certificate. Travel to be quoted separate.  A total of 3 shelvesare required

DL30-0127

Services

Temperature measurement, 27 measuring points - Temperature measurement with 27 measuring points with a set value specified by the user, including certificate. Travel to be quoted separate.  A total of 3 shelvesare required.

Execution of IQ/OQ

Execution of IQ/OQ in accordance with qualification folder. Travel to be quoted separate

DL41-0200

Services

Execution of IQ/OQ - Execution of IQ/OQ in accordance with qualification folder. Travel to be quoted separate.

Execution of IQ/OQ/PQ

Execution of IQ/OQ/PQ in accordance with qualification folder. Travel to be quoted separate

DL44-0500

Services

Execution of IQ/OQ/PQ - Execution of IQ/OQ/PQ in accordance with qualification folder. Travel to be quoted separate.

BRONZE 3-year maintenance contract

Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate. 10% Discount on Spare Parts and Labor for any additional Services needed Wear + tear parts to be purchased or billed to customer. Travel to be quoted as separate

DL20-0720

Services

BRONZE 3-year maintenance contract - Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate. 10% Discount on Spare Parts and Labor for any additional Services needed Wear + tear parts to be purchased or billed to customer. Travel to be quoted as separate.

Unit installation

Connect the unit to the customer-side connections (electricity, water, wastewater, gas), basic functions check, brief operating instructions. (excl.: unpacking, setup, controller instructions, programming, installation work) Travel to be quoted as separate

DL10-0100

Services

Unit installation - Connect the unit to the customer-side connections (electricity, water, wastewater, gas), basic functions check, brief operating instructions. (excl.: unpacking, setup, controller instructions, programming, installation work) Travel to be quoted as separate.

Unit instructions

Instruction regarding operating principle and basic functions of the unit, operation of the control electronics including programming. Travel to be quoted as separate Limited to 3 hours

DL10-0500

Services

Unit instructions - Instruction regarding operating principle and basic functions of the unit, operation of the control electronics including programming. Travel to be quoted as separate Limited to 3 hours.

1-year warranty extension

The warranty is extended by 1 year from the delivery date, wear parts are excluded

DL50-0010

Services

1-year warranty extension - The warranty is extended by 1 year from the delivery date, wear parts are excluded

SILVER 3-year maintenance contract

Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate 15% Discount on Spare Parts and Labor for any additional Services needed One additional courtesy visit per year can be used for service visit or operator training. Wear + tear parts to be purchased or billed to customer. Travel to be quoted separate

DL20-0810

Services

SILVER 3-year maintenance contract - Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate 15% Discount on Spare Parts and Labor for any additional Services needed One additional courtesy visit per year can be used for service visit or operator training. Wear + tear parts to be purchased or billed to customer. Travel to be quoted separate.

GOLD 3-year maintenance contract

Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate of Temperature. 25% Discount on Spare Parts and Labor for any additional Services needed. One additional courtesy visit per year can be used for service visit or operator. Wear + tear parts to be purchased or billed to customer. Travel to be quoted separate

DL20-0910

Services

GOLD 3-year maintenance contract - Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate of Temperature. 25% Discount on Spare Parts and Labor for any additional Services needed. One additional courtesy visit per year can be used for service visit or operator. Wear + tear parts to be purchased or billed to customer. Travel to be quoted separate.

Preventive maintenance 

One-off maintenance service in accordance with maintenance schedule. Visual inspection of mechanical and electrical components, testing of all key functions. Checking a test temperature specified by the user in center of usable space without certificate. Wear + tear parts need to be purchased or billed to customer. Travel to be quoted as separate

DL20-0602

Services

Preventive maintenance  - One-off maintenance service in accordance with maintenance schedule. Visual inspection of mechanical and electrical components, testing of all key functions. Checking a test temperature specified by the user in center of usable space without certificate. Wear + tear parts need to be purchased or billed to customer. Travel to be quoted as separate.

Temperature calibration

Calibration of one (1) test temperature specified by the user in center of chamber, including certificate Travel to be quoted separate

DL30-0120

Services

Temperature calibration - Calibration of one (1) test temperature specified by the user in center of chamber, including certificate Travel to be quoted separate.

Measurement of air exchange rate

Including certificate (in accordance with ASTM D5374)

DL33-0000

Services

Measurement of air exchange rate - including certificate (in accordance with ASTM D5374)

Suggested products

Compare products:

Or add another product.