Model FP 720 | Drying and heating chambers with forced convection and program functions

Benefits
  • High temperature accuracy thanks to APT.line™ technology
  • User-friendly controller with large display
  • Computer interface: Ethernet
  • Class 2 independent adjustable temperature safety device (DIN 12880) and class 3.1 independent temperature safety device (DIN 12880) with visual/acoustic alarm available for selection on the controller

Configure your product with options and accessories and request it directly here.

Product description

A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying times and particularly fast heating – even for chambers under full loads.

Important characteristics

  • Temperature range: +12°C above ambient temperature up to +300°C
  • High temperature accuracy thanks to APT.line™ technology
  • Adjustable fan speed
  • Controller with interval and real-time programming
  • Electromechanical control of the exhaust air flap
  • 2 chrome-plated racks
  • Class 2 independent adjustable temperature safety device (DIN 12880) and class 3.1 independent temperature safety device (DIN 12880) with visual/acoustic alarm available for selection on the controller
  • Ergonomic handle design
  • Computer interface: Ethernet
  • Internal data logger, measured values can be read out in open format via USB

Technical specifications

Data
DesignationFP720-400VFP720UL-208V
Article Number9010-03669010-0370
Option model

Standard

Standard

Performance Data Temperature
Temperature range+12 °C above ambient temperature to 300 °C+12 °C above ambient temperature to 300 °C
Temperature uniformity at 150°C2.4 ± K2.4 ± K
Temperature fluctuation at 150°C0.6 ± K0.6 ± K
Heating up time to 150°C25 min25 min
Recovery time after door was opened for 30 s at 150°C6 min6 min
Air change data
Air change rate at 100°C5 x/h5 x/h
Electrical data
Rated Voltage400 V208 V
Power frequency50/60 Hz60 Hz
Nominal power4,5 kW4,5 kW
Unit fuse16,0 A16,0 A
Phase (Nominal voltage)3~/N/PE3~
Dimensions and weights
Interior volume26 cu.ft.26 cu.ft.
Net weight of the unit (empty)366 lbs366 lbs
Load per rack99 lbs99 lbs
Permitted load694 lbs694 lbs
Wall clearance back6,3 in6,3 in
Wall clearance sidewise3,94 in3,94 in
Housing dimensions not incl. fittings and connections
Width net45.67 in45.67 in
Height net62.6 in62.6 in
Depth net32.13 in32.13 in
Internal Dimensions
Interior width39.37 in39.37 in
Interior height51.18 in51.18 in
Interior depth22.6 in22.6 in
Unit doors22
Environment-specific data
Sound-pressure level43 dB(A)43 dB(A)
Energy consumption at 100°C510 Wh/h510 Wh/h
Energy consumption at 150°C880 Wh/h880 Wh/h
Fixtures
Number of shelves (std./max.)2/162/16

Downloads

Drying and heating chambers

ED | ED-S | FD | FD-S | FED | FP | M series

pdf, 2.21 MB

Drying and heating chambers (FP series) - Drying chambers, constant climate chambers, dynamic climate chambers and cooling incubators test the service life of MinebeaMitsumi spindle motors

MinebeaMitsumi Technology Center Europe GmbH

pdf, 479.77 KB

FP series

pdf, 7.84 MB

Data Sheet Model FP 720

pdf, 700.54 KB

Options, Accessories, Services

Sorry, no result could be found. Check the spelling or use a new search term.

Rack

Max. load per rack 45 kg. chrome plated

8012-2044

Shelves

Rack - chrome plated

Rack

Max. load per rack 45 kg. stainless steel

8012-2170

Shelves

Rack - stainless steel

Shelf, perforated

Max. load per rack 40 kg. Stainless steel

8012-2178

Shelf

Shelf, perforated - Stainless steel

Rack, heavy load

Max. load per rack 70 kg. Stainless steel

8012-2185

Reinforced shelf racks

Rack, heavy load - Stainless steel

Rack accessories

Fasteners (1 set of 4) for additional security of racks

8012-0531

8012-0531-Gittersicherung-Set_Web_670x515.jpg

Rack accessories - fasteners (1 set of 4) for additional security of racks

APT-COM™ 4 BASIC-Edition

For simple logging and documentation requirements with up to 5 networked units.. version 4, BASIC edition

9053-0039

Multi Management Software APT-COM™

APT-COM™ 4 BASIC-Edition - for simple logging and documentation requirements with up to 5 networked units.

APT-COM™ 4 PROFESSIONAL-Edition

Convenient unit and user management built on the BASIC edition. Suitable for networking up to 100 units.. version 4, PROFESSIONAL edition

9053-0040

Multi Management Software APT-COM™

APT-COM™ 4 PROFESSIONAL-Edition - convenient unit and user management built on the BASIC edition. Suitable for networking up to 100 units.

APT-COM™ 4 GLP-Edition

For working under GLP-compliant conditions. Measured values are documented in a tamper-proof way in line with the requirements of FDA Regulation 21 CFR 11.. version 4, GLP edition

9053-0042

Multi Management Software APT-COM™

APT-COM™ 4 GLP-Edition - for working under GLP-compliant conditions. Measured values are documented in a tamper-proof way in line with the requirements of FDA Regulation 21 CFR 11.

pH-neutral detergent

Concentrated, for gentle remove of residual contaminants; 1 kg

8012-2250

1002-0016-Neutralreiniger-100x85_Web_670x515.jpg

pH-neutral detergent - concentrated, for gentle remove of residual contaminants; 1 kg

Qualification documents

IQ/OQ documents – supporting documents for validation performed by customers, consisting of: IQ/OQ checklists incl. calibration guide and comprehensive unit documentation; parameters: temperature, CO2, O2, pressure, depending on unit. Hard copy inside folder

7007-0001

Qualification documents

IQ/OQ documents – supporting documents for validation performed by customers, consisting of: IQ/OQ checklists incl. calibration guide and comprehensive unit documentation; parameters: temperature, CO2, O2, pressure, depending on unit. Digital in PDF format

7057-0001

Qualification documents

IQ/OQ/PQ documents – supporting documents for validation performed by customers, according to customer requirements, PQ section added to qualification folder IQ/OQ; parameters: temperature, CO2, O2 – or pressure, depending on unit. Hard copy inside folder

7007-0005

Qualification documents

IQ/OQ/PQ documents – supporting documents for validation performed by customers, according to customer requirements, PQ section added to qualification folder IQ/OQ; parameters: temperature, CO2, O2 – or pressure, depending on unit. Digital in PDF format

7057-0005

Sorry, no result could be found. Check the spelling or use a new search term.

Analog output 4-20 mA

For temperature values (output not adjustable)

8012-2188

Access port with silicone plug

Left. 10 mm

8012-2198

Access port with silicone plug

Access port with silicone plug - 10 mm, left

Access port with silicone plug

Top. 10 mm

8012-2199

Access port with silicone plug

Access port with silicone plug - 10 mm, top

Access port with silicone plug

Right. 10 mm

8012-2206

Access port with silicone plug

Access port with silicone plug - 10 mm, right

Access port with silicone plug

Top. 100 mm

8012-2208

Access port with silicone plug

Access port with silicone plug - 100 mm, top

Access port with silicone plug

Left. 30 mm

8012-2210

Access port with silicone plug

Access port with silicone plug - 30 mm, left

Access port with silicone plug

Top. 30 mm

8012-2211

Access port with silicone plug

Access port with silicone plug - 30 mm, top

Access port with silicone plug

Right. 30 mm

8012-2212

Access port with silicone plug

Access port with silicone plug - 30 mm, right

Access port with silicone plug

Left. 50 mm

8012-2213

Access port with silicone plug

Access port with silicone plug - 50 mm, left

Access port with silicone plug

Top. 50 mm

8012-2214

Access port with silicone plug

Access port with silicone plug - 50 mm, top

Access port with silicone plug

Right. 50 mm

8012-2215

Access port with silicone plug

Access port with silicone plug - 50 mm, right

Calibration certificate, temperature

For temperature, measurement in center of chamber at specified temperature

8012-2227

Calibration certificate, temperature

Temperature measurement incl. certificate, 15- 18 measuring points at specified temperature

8012-2228

Calibration certificate, temperature

Temperature measurement incl. certificate and 27 measuring points at specified temperature

8012-2229

Calibration certificate, temperature

Temperature measurement incl. certificate, 9 measuring points at specified temperature

8012-2230

Calibration certificate, expanded

For temperature; for extending the measurement in center of chamber to include another test temperature

8012-2231

Measurement of air exchange rate

In accordance with ASTM D5374, definition and protocol according to ambient temperature

8012-2232

Pt 100 temperature sensor

Additional flexible Pt 100, interior, for displaying the temperature on the unit display

8012-2193

Pt 100 temperature sensor

Pt 100 temperature sensor - additional flexible Pt 100, interior, for displaying the temperature on the unit display

Access port with silicone plug

Left. 100 mm

8012-2207

Access port with silicone plug

Access port with silicone plug - 100 mm, left

Access port with silicone plug

Right. 100 mm

8012-2209

Access port with silicone plug

Access port with silicone plug - 100 mm, right

HEPA air filter

On fresh air supply for unit; filter classification H14 (acc. to. EN 1822-1:2009, > 99.995% at 0.3 µm); not in conjunction with reinforced heating output, reinforced fan

8012-2222

HEPA air filter

HEPA air filter - On fresh air supply for unit; filter classification H14 (acc. to. EN 1822-1:2009, > 99.995% at 0.3 µm); not in conjunction with reinforced heating output, reinforced fan

Inner chamber, reinforced

Max. total load 350 kg

8012-2226

Door lock

Lockable door handle

8012-2238

Door lock

Door lock - lockable door handle

Interior lighting

With two 27 W light bulbs. 400 V option model

8012-2191

Sorry, no result could be found. Check the spelling or use a new search term.

Temperature calibration

Extension of calibration of one (1) additional test temperature specified by the user in the center of the usable space, including certificate Travel to be quoted separate

DL30-0102

Services

Temperature calibration - Extension of calibration of one (1) additional test temperature specified by the user in the center of the usable space, including certificate Travel to be quoted separate.

Temperature measurement, 9 measuring points

Temperature measurement with 9 measuring points with a set value specified by the user, including certificate. Travel to be quoted separate.  A total of 3 shelvesare required

DL30-0109

Services

Temperature measurement, 9 measuring points - Temperature measurement with 9 measuring points with a set value specified by the user, including certificate. Travel to be quoted separate.  A total of 3 shelvesare required.

Temperature measurement, 18 measuring points

Temperature measurement with 18 measuring points with a set value specified by the user, including certificate. Travel to be quoted separate.  A total of 2 shelvesare required

DL30-0118

Services

Temperature measurement, 18 measuring points - Temperature measurement with 18 measuring points with a set value specified by the user, including certificate. Travel to be quoted separate.  A total of 2 shelvesare required.

Temperature measurement, 27 measuring points

Temperature measurement with 27 measuring points with a set value specified by the user, including certificate. Travel to be quoted separate.  A total of 3 shelvesare required

DL30-0127

Services

Temperature measurement, 27 measuring points - Temperature measurement with 27 measuring points with a set value specified by the user, including certificate. Travel to be quoted separate.  A total of 3 shelvesare required.

Execution of IQ/OQ

Execution of IQ/OQ in accordance with qualification folder. Travel to be quoted separate

DL41-0200

Services

Execution of IQ/OQ - Execution of IQ/OQ in accordance with qualification folder. Travel to be quoted separate.

Execution of IQ/OQ/PQ

Execution of IQ/OQ/PQ in accordance with qualification folder. Travel to be quoted separate

DL44-0500

Services

Execution of IQ/OQ/PQ - Execution of IQ/OQ/PQ in accordance with qualification folder. Travel to be quoted separate.

BRONZE 3-year maintenance contract

Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate. 10% Discount on Spare Parts and Labor for any additional Services needed Wear + tear parts to be purchased or billed to customer. Travel to be quoted as separate

DL20-0720

Services

BRONZE 3-year maintenance contract - Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate. 10% Discount on Spare Parts and Labor for any additional Services needed Wear + tear parts to be purchased or billed to customer. Travel to be quoted as separate.

Unit installation

Connect the unit to the customer-side connections (electricity, water, wastewater, gas), basic functions check, brief operating instructions. (excl.: unpacking, setup, controller instructions, programming, installation work) Travel to be quoted as separate

DL10-0100

Services

Unit installation - Connect the unit to the customer-side connections (electricity, water, wastewater, gas), basic functions check, brief operating instructions. (excl.: unpacking, setup, controller instructions, programming, installation work) Travel to be quoted as separate.

Unit instructions

Instruction regarding operating principle and basic functions of the unit, operation of the control electronics including programming. Travel to be quoted as separate Limited to 3 hours

DL10-0500

Services

Unit instructions - Instruction regarding operating principle and basic functions of the unit, operation of the control electronics including programming. Travel to be quoted as separate Limited to 3 hours.

1-year warranty extension

The warranty is extended by 1 year from the delivery date, wear parts are excluded

DL50-0010

Services

1-year warranty extension - The warranty is extended by 1 year from the delivery date, wear parts are excluded

SILVER 3-year maintenance contract

Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate 15% Discount on Spare Parts and Labor for any additional Services needed One additional courtesy visit per year can be used for service visit or operator training. Wear + tear parts to be purchased or billed to customer. Travel to be quoted separate

DL20-0810

Services

SILVER 3-year maintenance contract - Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate 15% Discount on Spare Parts and Labor for any additional Services needed One additional courtesy visit per year can be used for service visit or operator training. Wear + tear parts to be purchased or billed to customer. Travel to be quoted separate.

GOLD 3-year maintenance contract

Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate of Temperature. 25% Discount on Spare Parts and Labor for any additional Services needed. One additional courtesy visit per year can be used for service visit or operator. Wear + tear parts to be purchased or billed to customer. Travel to be quoted separate

DL20-0910

Services

GOLD 3-year maintenance contract - Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate of Temperature. 25% Discount on Spare Parts and Labor for any additional Services needed. One additional courtesy visit per year can be used for service visit or operator. Wear + tear parts to be purchased or billed to customer. Travel to be quoted separate.

Preventive maintenance 

One-off maintenance service in accordance with maintenance schedule. Visual inspection of mechanical and electrical components, testing of all key functions. Checking a test temperature specified by the user in center of usable space without certificate. Wear + tear parts need to be purchased or billed to customer. Travel to be quoted as separate

DL20-0602

Services

Preventive maintenance  - One-off maintenance service in accordance with maintenance schedule. Visual inspection of mechanical and electrical components, testing of all key functions. Checking a test temperature specified by the user in center of usable space without certificate. Wear + tear parts need to be purchased or billed to customer. Travel to be quoted as separate.

Temperature calibration

Calibration of one (1) test temperature specified by the user in center of chamber, including certificate Travel to be quoted separate

DL30-0120

Services

Temperature calibration - Calibration of one (1) test temperature specified by the user in center of chamber, including certificate Travel to be quoted separate.

Measurement of air exchange rate

Including certificate (in accordance with ASTM D5374)

DL33-0000

Services

Measurement of air exchange rate - including certificate (in accordance with ASTM D5374)

Suggested products

Compare products:

Or add another product.