Model 23
Dimensions
Product image
Product image

Model ED 23 | Drying and heating chambers with gravity convection

Benefits
  • Uniform drying conditions thanks to APT.line™ technology
  • Identical test conditions throughout the chamber interior independent of sample size and quantity
  • Outstanding thermal insulation saves operation costs

Configure your product with options and accessories and request it directly here.

Product description

The strengths of a BINDER ED series drying chamber include routine drying and sterilization tasks up to 300 °C. Thanks to the gravity convection, all thermal processes which use this drying chamber are highly efficient. The ED series ensures fast, uniform drying.

Important characteristics

  • Temperature range: room temperature plus 5 °C to 300 °C
  • APT.line™ preheating chamber technology
  • Gravity convection
  • Adjustable exhaust air flap
  • Controller with timer functions
  • 2 chrome-plated racks
  • Class 2 independent adjustable temperature safety device (DIN 12880) with visual alarm

Technical specifications

Designation
Article Number
Option model
Temperature range
Temperature range without illumination cassettes
Temperature range with 100% illumination
Temperature uniformity dependent on set value
Temperature uniformity at -80°C
Temperature uniformity with 100% illumination
Temperature uniformity without illumination cassettes
Temperature uniformity at 37°C
Temperature uniformity at 100°C
Temperature uniformity at 150°C
Temperature fluctuation dependent on set value
Temperature fluctuation at -80°C
Temperature fluctuation at 37°C
Temperature fluctuation with 100% illumination
Temperature fluctuation without illumination cassettes
Temperature fluctuation at 100°C
Temperature fluctuation at 150°C
Heating up time to 100°C
Heating up time to 150°C
Heating up time to 37°C
Average heating-up rate according to IEC 60068-3-5
Cooling down time from 110°C to -40°C
Cooling down time from 180°C to -40°C
Cooling down time from 180°C to -70°C
Cooling down time from 22°C to -80°C
Average cooling down time according to IEC 60068-3-5
Max. heat compensation at 37°C
Max. heat compensation at 40°C
Max. heat compensation at 40°C with illumination
Recovery time after door was opened for 30 s at 150°C
Recovery time after door was opened for 30 s at 37°C
Temperature range with humidity and without illumination cassettes
Temperature range with humidity and 100% illumination
Temperature range with humidity
Humidity range
Humidity range without illumination cassettes
Humidity range with 100% illumination
Temperature uniformity at 25°C and 60% RH
Temperature uniformity at 40°C and 75% RH
Temperature uniformity with illumination at 25°C and 60% RH
Temperature uniformity with illumination at 40°C and 75% RH
Temperature uniformity with humidity dependent on set value
Temperature fluctuation at 25°C and 60% RH
Temperature fluctuation at 40°C and 75% RH
Temperature fluctuation with illumination at 25°C and 60% RH
Temperature fluctuation with illumination at 40°C and 75% RH
Temperature fluctuation with humidity dependent on set value
Humidity fluctuation at 25°C and 60% RH
Humidity fluctuation at 40°C and 75% RH
Humidity fluctuation with illumination at 25°C and 60% RH
Humidity fluctuation with illumination at 40°C and 75% RH
Humidity fluctuation with humidity dependent on set value
Recovery time after door was opened for 30 s at 25°C and 60% RH
Recovery time after door was opened for 30 s at 40°C and 75% RH
Recovery time after door was opened for 30 s with illumination at 25°C and 60% RH
Recovery time after door was opened for 30 s with illumination at 40°C and 75% RH
Max. heat compensation at 25°C and 90% RH
CO₂ range
CO₂ measuring technology
CO₂ recovery time after door was opened for 30 s at 5 vol. % CO₂
Standard O₂ control range
O₂ control ranges with option: O₂ range
O₂ recovery time after door was opened for 30 s at 5 vol. % O₂
ICH compliant illumination for photo stability testing
ICH compliant illumination for photo stability testing
Daylight tubes
Daylight tubes
Fluora® growth lamps
Arabidopsis lamps
Air circulation (approx.)
Volumetric flow rate of exhaust air acc. to EN 1539 at 50 °C
Air change rate at 100°C
Air change rate at 150°C
Permitted end vacuum
Leckrate
Pressure fluctuation over time at 50 mbar
Pressure fluctuation over time at 400 mbar
Highest permitted solvent quantity (at T-180°C, M-100g/mol, U-40g/m3, K=0,5)
Rated Voltage
Power frequency
Nominal power
Unit fuse
Phase (Nominal voltage)
Vacuum connection with small flange
Measuring access port with small flange
Inert gas connection with flow limiter (RP")
Compressed air connection for pressure-encapsulation
Interior volume
Net weight of the unit (empty)
Load per rack
Permitted load
Wall clearance back
Wall clearance sidewise
Width net
Height net
Depth net
Interior width
Interior height
Interior depth
Viewing window width
Viewing window height
Inner doors
Unit doors
Sound-pressure level
Average heat compensation at set value -80°C and Ta = 21°C
Energy consumption at 25°C and 60% RH
Energy consumption at 100°C
Energy consumption at 150°C
Energy consumption at 20°C
Energy consumption at 37°C
Energy consumption at 37°C and 75% RH
Energy consumption at 37°C and with illumination
Energy consumption at 40°C and 75% RH
Energy consumption at 85°C and 85% RH
Energieverbrauch bei Sollwert -80 °C und Tᵤ = 20 °C
Number of shelves (std./max.)
Number of illumination cassettes (std./max.)
Freezer racks per compartment
Cryoboxes, 50 mm

Downloads

Drying and heating chambers

ED | ED-S | FD | FD-S | FED | FP | M series

pdf, 2.21 MB

Drying and heating chambers (FP series) - Drying chambers, constant climate chambers, dynamic climate chambers and cooling incubators test the service life of MinebeaMitsumi spindle motors

MinebeaMitsumi Technology Center Europe GmbH

pdf, 479.77 KB

BD | ED |  FD series

pdf, 10.14 MB

Data Sheet Model ED 23

pdf, 206.18 KB

Options, Accessories, Services

Sorry, no result could be found. Check the spelling or use a new search term.

Rubber pads

Set anti-slip feet

8012-2030

Rack

Chrome plated

8012-2031

Shelves

Rack - chrome plated

Rack

Stainless steel

8012-2046

Shelves

Rack - stainless steel

pH-neutral detergent

Concentrated, for gentle remove of residual contaminants; 1 kg

8012-2250

1002-0016-Neutralreiniger-100x85_Web_670x515.jpg

pH-neutral detergent - concentrated, for gentle remove of residual contaminants; 1 kg

Qualifizierungsunterlagen

7007-0001

Qualifizierungsunterlagen

7057-0001

Qualifizierungsunterlagen

7007-0005

Qualifizierungsunterlagen

7057-0005

Sorry, no result could be found. Check the spelling or use a new search term.

Door gasket

Made of FKM, silicone-free

8012-0493

Door lock

Lockable door handle

8012-1246

Door lock

Door lock - lockable door handle

Measurement of air exchange rate

In accordance with ASTM D5374, definition and protocol according to ambient temperature

8012-0195

Access port with silicone plug

Top. 30 mm

8012-0539

Access port with silicone plug

Access port with silicone plug - 30 mm, top

Access port with silicone plug

Back. 30 mm

8012-0540

Access port with silicone plug

Access port with silicone plug - 30 mm, back

Access port with silicone plug

Top. 50 mm

8012-0545

Access port with silicone plug

Access port with silicone plug - 50 mm, top

Access port with silicone plug

Back. 50 mm

8012-0546

Access port with silicone plug

Access port with silicone plug - 50 mm, back

Calibration certificate, expanded

For temperature; for extending the measurement in center of chamber to include another test temperature

8012-1115

Calibration certificate, temperature

For temperature, measurement in center of chamber at specified temperature

8012-1134

Access port with silicone plug

Top. 10 mm

8012-1262

Access port with silicone plug

Access port with silicone plug - 10 mm, top

Access port with silicone plug

Right. 10 mm

8012-1268

Access port with silicone plug

Access port with silicone plug - 10 mm, right

Access port with silicone plug

Left. 10 mm

8012-1275

Access port with silicone plug

Access port with silicone plug - 10 mm, left

Access port with silicone plug

Back. 10 mm

8012-1282

Access port with silicone plug

Access port with silicone plug - 10 mm, back

Calibration certificate, temperature

Temperature measurement incl. certificate, 9 measuring points at specified temperature

8012-1551

Calibration certificate, temperature

Temperature measurement incl. certificate, 15- 18 measuring points at specified temperature

8012-1572

Calibration certificate, temperature

Temperature measurement incl. certificate and 27 measuring points at specified temperature

8012-1593

Analog output 4-20 mA

For temperature values (output not adjustable)

8012-0430

Access port with silicone plug

Left. 30 mm

8012-0537

Access port with silicone plug

Access port with silicone plug - 30 mm, left

Access port with silicone plug

Right. 50 mm

8012-0541

Access port with silicone plug

Access port with silicone plug - 50 mm, right

Access port with silicone plug

Left. 50 mm

8012-0542

Access port with silicone plug

Access port with silicone plug - 50 mm, left

Pt 100 temperature sensor

Additional flexible Pt 100, interior, with external connection incl. LEMO connector (3-pin)

8012-1173

Pt 100 temperature sensor

Pt 100 temperature sensor - additional flexible Pt 100, interior, with external connection incl. LEMO connector (3-pin)

Access port with silicone plug

Right. 30 mm

8012-0536

Access port with silicone plug

Access port with silicone plug - 30 mm, right

Viewing window and interior lighting

Viewing window in door, 180 x 180 mm, and 15 W interior lighting. 230 V option model

8012-0378

Viewing window in the door

Viewing window and interior lighting - 230 V option model, viewing window in door, 180 x 180 mm, and 15 W interior lighting

Class 3.1 independent temperature safety device

With visual alarm (DIN 12880)

8012-0032

Alarm function for overheating

Switchable acoustic alarm, with adjustable limit value on the independent temperature safety device. 230/400 V option model

8012-1299

Sorry, no result could be found. Check the spelling or use a new search term.

Temperature measurement, 9 measuring points

Temperature measurement with 9 measuring points with a set value specified by the user, including certificate. Travel to be quoted separate.  A total of 3 shelvesare required

DL30-0109

Services

Temperature measurement, 9 measuring points - Temperature measurement with 9 measuring points with a set value specified by the user, including certificate. Travel to be quoted separate.  A total of 3 shelvesare required.

Temperature measurement, 18 measuring points

Temperature measurement with 18 measuring points with a set value specified by the user, including certificate. Travel to be quoted separate.  A total of 2 shelvesare required

DL30-0118

Services

Temperature measurement, 18 measuring points - Temperature measurement with 18 measuring points with a set value specified by the user, including certificate. Travel to be quoted separate.  A total of 2 shelvesare required.

Temperature measurement, 27 measuring points

Temperature measurement with 27 measuring points with a set value specified by the user, including certificate. Travel to be quoted separate.  A total of 3 shelvesare required

DL30-0127

Services

Temperature measurement, 27 measuring points - Temperature measurement with 27 measuring points with a set value specified by the user, including certificate. Travel to be quoted separate.  A total of 3 shelvesare required.

Measurement of air exchange rate

Including certificate (in accordance with ASTM D5374)

DL33-0000

Services

Measurement of air exchange rate - including certificate (in accordance with ASTM D5374)

Execution of IQ/OQ

Execution of IQ/OQ in accordance with qualification folder. Travel to be quoted separate

DL40-0100

Services

Execution of IQ/OQ - Execution of IQ/OQ in accordance with qualification folder. Travel to be quoted separate.

Execution of IQ/OQ/PQ

Execution of IQ/OQ/PQ in accordance with qualification folder. Travel to be quoted separate

DL44-0500

Services

Execution of IQ/OQ/PQ - Execution of IQ/OQ/PQ in accordance with qualification folder. Travel to be quoted separate.

Temperature calibration

Extension of calibration of one (1) additional test temperature specified by the user in the center of the usable space, including certificate Travel to be quoted separate

DL30-0102

Services

Temperature calibration - Extension of calibration of one (1) additional test temperature specified by the user in the center of the usable space, including certificate Travel to be quoted separate.

1-year warranty extension

The warranty is extended by 1 year from the delivery date, wear parts are excluded

DL50-0010

Services

1-year warranty extension - The warranty is extended by 1 year from the delivery date, wear parts are excluded

BRONZE 3-year maintenance contract

Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate. 10% Discount on Spare Parts and Labor for any additional Services needed Wear + tear parts to be purchased or billed to customer. Travel to be quoted as separate

DL20-0720

Services

BRONZE 3-year maintenance contract - Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate. 10% Discount on Spare Parts and Labor for any additional Services needed Wear + tear parts to be purchased or billed to customer. Travel to be quoted as separate.

Unit instructions

Instruction regarding operating principle and basic functions of the unit, operation of the control electronics including programming. Travel to be quoted as separate Limited to 3 hours

DL10-0540

Services

Unit instructions - Instruction regarding operating principle and basic functions of the unit, operation of the control electronics including programming. Travel to be quoted as separate Limited to 3 hours.

SILVER 3-year maintenance contract

Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate 15% Discount on Spare Parts and Labor for any additional Services needed One additional courtesy visit per year can be used for service visit or operator training. Wear + tear parts to be purchased or billed to customer. Travel to be quoted separate

DL20-0815

Services

SILVER 3-year maintenance contract - Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate 15% Discount on Spare Parts and Labor for any additional Services needed One additional courtesy visit per year can be used for service visit or operator training. Wear + tear parts to be purchased or billed to customer. Travel to be quoted separate.

GOLD 3-year maintenance contract

Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate of Temperature. 25% Discount on Spare Parts and Labor for any additional Services needed. One additional courtesy visit per year can be used for service visit or operator. Wear + tear parts to be purchased or billed to customer. Travel to be quoted separate

DL20-0915

Services

GOLD 3-year maintenance contract - Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate of Temperature. 25% Discount on Spare Parts and Labor for any additional Services needed. One additional courtesy visit per year can be used for service visit or operator. Wear + tear parts to be purchased or billed to customer. Travel to be quoted separate.

Preventive maintenance 

One-off maintenance service in accordance with maintenance schedule. Visual inspection of mechanical and electrical components, testing of all key functions. Checking a test temperature specified by the user in center of usable space without certificate. Wear + tear parts need to be purchased or billed to customer. Travel to be quoted as separate

DL20-0601

Services

Preventive maintenance  - One-off maintenance service in accordance with maintenance schedule. Visual inspection of mechanical and electrical components, testing of all key functions. Checking a test temperature specified by the user in center of usable space without certificate. Wear + tear parts need to be purchased or billed to customer. Travel to be quoted as separate.

Temperature calibration

Calibration of one (1) test temperature specified by the user in center of chamber, including certificate Travel to be quoted separate

DL30-0110

Services

Temperature calibration - Calibration of one (1) test temperature specified by the user in center of chamber, including certificate Travel to be quoted separate.

Unit installation

Connect the unit to the customer-side connections (electricity, water, wastewater, gas), basic functions check, brief operating instructions. (excl.: unpacking, setup, controller instructions, programming, installation work) Travel to be quoted as separate

DL10-0160

Services

Unit installation - Connect the unit to the customer-side connections (electricity, water, wastewater, gas), basic functions check, brief operating instructions. (excl.: unpacking, setup, controller instructions, programming, installation work) Travel to be quoted as separate.

Suggested products

Compare products:

Or add another product.