Model MKT 115 | Dynamic climate chambers for rapid temperature changes with extended low temperature range

Benefits
  • Homogeneous climate conditions thanks to APT.line™ technology
  • Comprehensive programming and data acquisition
  • Large heated viewing window

Configure your product with options and accessories and request it directly here.

Product description

Temperature ranges between -70 °C and 180 °C, with the added benefit of natural simulation, are what make the BINDER MKT series so unique. At the same time, this environmental simulation chamber fulfills the very highest precision and performance requirements for cyclical temperature tests.

Important characteristics

  • Temperature range: -70 °C to +180 °C
  • 4 zero-voltage relay contacts
  • APT.line™ preheating chamber technology
  • Programmable condensation protection for test material
  • Heated viewing window with LED interior lighting
  • BINDER Multi Management software APT-COM™ Basic Edition
  • Troubleshooting system with visual and audible alarms
  • Intuitive touchscreen controller with time-segment and real-time programming
  • Internal data logger, measured values can be read out in open format via USB
  • Access port with silicone plug: 50 mm, left
  • Class 2 independent adjustable temperature safety device (DIN 12880) with visual alarm
  • 4 castors, two with brakes
  • Computer interface: Ethernet
  • Adjustable ramp function
  • Integrated chart recorder
  • Real-time clock
  • Door heating
  • 1 stainless steel rack
  • Inner chamber made of stainless steel
  • CFC-free refrigerants R-452A and R-23
  • Cooling with cascade compressor cooling unit

Technical specifications

Data
DesignationMKT115-400VMKT115-480V-C
Article Number9020-03859020-0363
Option model

Standard

Standard

Performance Data Temperature
Temperature range-70...180 °C-70...180 °C
Temperature uniformity dependent on set value0.2...1.8 ± K0.2...1.8 ± K
Temperature fluctuation dependent on set value0.1...0.6 ± K0.1...0.6 ± K
Average heating-up rate according to IEC 60068-3-55.3 K/min5.3 K/min
Cooling down time from 180°C to -70°C110 min110 min
Average cooling down time according to IEC 60068-3-54.2 K/min4.2 K/min
Electrical data
Rated Voltage400 V480 V
Power frequency50 Hz60 Hz
Nominal power5,5 kW5,5 kW
Unit fuse16,0 A16,0 A
Phase (Nominal voltage)3~/N/PE3~
Dimensions and weights
Interior volume4 cu.ft.4 cu.ft.
Net weight of the unit (empty)672 lbs672 lbs
Load per rack66 lbs66 lbs
Permitted load132 lbs132 lbs
Wall clearance back11,81 in11,81 in
Wall clearance sidewise7,87 in7,87 in
Housing dimensions not incl. fittings and connections
Width net38.58 in38.58 in
Height net67.91 in67.91 in
Depth net34.06 in34.06 in
Internal Dimensions
Interior width23.62 in23.62 in
Interior height18.9 in18.9 in
Interior depth15.75 in15.75 in
Unit doors11
Environment-specific data
Sound-pressure level64 dB(A)67 dB(A)
Energy consumption at 20°C600 Wh/h600 Wh/h
Fixtures
Number of shelves (std./max.)1/41/4

Downloads

Dynamic climate chambers

MK | MKF | MKT | MKFT series

pdf, 2.3 MB

Drying and heating chambers (FP series) - Drying chambers, constant climate chambers, dynamic climate chambers and cooling incubators test the service life of MinebeaMitsumi spindle motors

MinebeaMitsumi Technology Center Europe GmbH

pdf, 479.77 KB

Data Sheet Model MKT 115

pdf, 674.91 KB

Options, Accessories, Services

Sorry, no result could be found. Check the spelling or use a new search term.

Rack accessories

Fasteners (1 set of 4) for additional security of racks

8012-2280

Rack

Stainless steel

8012-2048

Shelves

Rack - stainless steel

Rack, reinforced

Stainless steel, with fasteners (1 set of 4)

8012-0709

Shelf

Rack, reinforced - stainless steel, with fasteners (1 set of 4)

RS 485 / RS 422 interface converter

RS 422 cable set and RS 485 / RS 422 interface converter for connection to 10-way plug distributor. 115 V option model

8012-0599

RS 485 / RS 422 interface converter

RS 422 cable set and RS 485 / RS 422 interface converter for connection to 10-way plug distributor. 230 V option model

8012-0589

APT-COM™ 4 PROFESSIONAL-Edition

Convenient unit and user management built on the BASIC edition. Suitable for networking up to 100 units.. version 4, PROFESSIONAL edition

9053-0040

Multi Management Software APT-COM™

APT-COM™ 4 PROFESSIONAL-Edition - convenient unit and user management built on the BASIC edition. Suitable for networking up to 100 units.

APT-COM™ 4 GLP-Edition

For working under GLP-compliant conditions. Measured values are documented in a tamper-proof way in line with the requirements of FDA Regulation 21 CFR 11.. version 4, GLP edition

9053-0042

Multi Management Software APT-COM™

APT-COM™ 4 GLP-Edition - for working under GLP-compliant conditions. Measured values are documented in a tamper-proof way in line with the requirements of FDA Regulation 21 CFR 11.

pH-neutral detergent

Concentrated, for gentle remove of residual contaminants; 1 kg

8012-2250

1002-0016-Neutralreiniger-100x85_Web_670x515.jpg

pH-neutral detergent - concentrated, for gentle remove of residual contaminants; 1 kg

Qualification documents

IQ/OQ documents – supporting documents for validation performed by customers, consisting of: IQ/OQ checklists incl. calibration guide and comprehensive unit documentation; parameters: temperature, CO2, O2, pressure, depending on unit. Hard copy inside folder

7007-0001

Qualification documents

IQ/OQ documents – supporting documents for validation performed by customers, consisting of: IQ/OQ checklists incl. calibration guide and comprehensive unit documentation; parameters: temperature, CO2, O2, pressure, depending on unit. Digital in PDF format

7057-0001

Qualification documents

IQ/OQ/PQ documents – supporting documents for validation performed by customers, according to customer requirements, PQ section added to qualification folder IQ/OQ; parameters: temperature, CO2, O2 – or pressure, depending on unit. Hard copy inside folder

7007-0005

Qualification documents

IQ/OQ/PQ documents – supporting documents for validation performed by customers, according to customer requirements, PQ section added to qualification folder IQ/OQ; parameters: temperature, CO2, O2 – or pressure, depending on unit. Digital in PDF format

7057-0005

Sorry, no result could be found. Check the spelling or use a new search term.

Temperature safety device class 2

With visual alarm (DIN 12880)

8012-1794

Calibration certificate, expanded

For temperature; for extending the measurement in center of chamber to include another test temperature

8012-1125

Calibration certificate, temperature

For temperature, measurement in center of chamber at specified temperature

8012-1144

Access port with silicone plug

Right. 30 mm

8012-1321

Access port with silicone plug

Access port with silicone plug - 30 mm, right

Access port with silicone plug

Left. 30 mm

8012-1324

Access port with silicone plug

Access port with silicone plug - 30 mm, left

Access port with silicone plug

Right. 50 mm

8012-1327

Access port with silicone plug

Access port with silicone plug - 50 mm, right

Access port with silicone plug

Left. 50 mm

8012-1330

Access port with silicone plug

Access port with silicone plug - 50 mm, left

Access port with silicone plug

Right. 80 mm

8012-1333

Access port with silicone plug

Access port with silicone plug - 80 mm, right

Access port with silicone plug

Left. 80 mm

8012-1336

Access port with silicone plug

Access port with silicone plug - 80 mm, left

Access port with silicone plug

Right. 125 mm

8012-1350

Access port with silicone plug

Access port with silicone plug - 125 mm, right

Access port with silicone plug

Left. 125 mm

8012-1353

Access port with silicone plug

Access port with silicone plug - 125 mm, left

Access port with silicone plug

Top. 100 mm

8012-1532

Access port with silicone plug

Access port with silicone plug - 100 mm, top

Access port with silicone plug

Top. 125 mm

8012-1535

Access port with silicone plug

Access port with silicone plug - 125 mm, top

Access port with silicone plug

Top. 80 mm

8012-1538

Access port with silicone plug

Access port with silicone plug - 80 mm, top

Access port with silicone plug

Right. 100 mm

8012-1541

Access port with silicone plug

Access port with silicone plug - 100 mm, right

Access port with silicone plug

Left. 100 mm

8012-1544

Access port with silicone plug

Access port with silicone plug - 100 mm, left

Calibration certificate, temperature

Temperature measurement incl. certificate, 15- 18 measuring points at specified temperature

8012-1582

Calibration certificate, temperature

Temperature measurement incl. certificate and 27 measuring points at specified temperature

8012-1603

Calibration certificate, temperature

Temperature measurement incl. certificate, 9 measuring points at specified temperature

8012-1561

Door lock

Lockable door handle

8012-1784

Door lock

Door lock - lockable door handle

Analog output 4-20 mA

For temperature values (output not adjustable)

8012-1785

RS 485 interface, 2-wire

Additional serial interface can be used parallel to Ethernet, for Multi Management Software APT-COM™

8012-1770

Pt 100 temperature sensor

Additional flexible Pt 100, interior, for displaying the temperature on the unit display

8012-1790

Pt 100 temperature sensor

Pt 100 temperature sensor - additional flexible Pt 100, interior, for displaying the temperature on the unit display

Compressed air connection

For the connection to an existing pressurized air network

8012-1804

Dry-air purge

Compressed air connection - for the connection to an existing pressurized air network

Dry-air purge

Uncontrolled, incl. connection; for preventing condensation

8012-1805

Dry-air purge

Dry-air purge - uncontrolled, incl. connection; for preventing condensation

Notch-type access port

Notch-type access port in door, 100 x 35 mm

8012-1852

Notch-type access port in door

Notch-type access port - notch-type access port in door, 100 x 35 mm

Sorry, no result could be found. Check the spelling or use a new search term.

BRONZE 3-year maintenance contract

Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate. 10% Discount on Spare Parts and Labor for any additional Services needed Wear + tear parts to be purchased or billed to customer. Travel to be quoted as separate

DL20-0710

Services

BRONZE 3-year maintenance contract - Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate. 10% Discount on Spare Parts and Labor for any additional Services needed Wear + tear parts to be purchased or billed to customer. Travel to be quoted as separate.

Temperature calibration

Extension of calibration of one (1) additional test temperature specified by the user in the center of the usable space, including certificate Travel to be quoted separate

DL30-0102

Services

Temperature calibration - Extension of calibration of one (1) additional test temperature specified by the user in the center of the usable space, including certificate Travel to be quoted separate.

Temperature measurement, 9 measuring points

Temperature measurement with 9 measuring points with a set value specified by the user, including certificate. Travel to be quoted separate.  A total of 3 shelvesare required

DL30-0109

Services

Temperature measurement, 9 measuring points - Temperature measurement with 9 measuring points with a set value specified by the user, including certificate. Travel to be quoted separate.  A total of 3 shelvesare required.

Temperature measurement, 18 measuring points

Temperature measurement with 18 measuring points with a set value specified by the user, including certificate. Travel to be quoted separate.  A total of 2 shelvesare required

DL30-0118

Services

Temperature measurement, 18 measuring points - Temperature measurement with 18 measuring points with a set value specified by the user, including certificate. Travel to be quoted separate.  A total of 2 shelvesare required.

Temperature measurement, 27 measuring points

Temperature measurement with 27 measuring points with a set value specified by the user, including certificate. Travel to be quoted separate.  A total of 3 shelvesare required

DL30-0127

Services

Temperature measurement, 27 measuring points - Temperature measurement with 27 measuring points with a set value specified by the user, including certificate. Travel to be quoted separate.  A total of 3 shelvesare required.

Execution of IQ/OQ

Execution of IQ/OQ in accordance with qualification folder. Travel to be quoted separate

DL41-0200

Services

Execution of IQ/OQ - Execution of IQ/OQ in accordance with qualification folder. Travel to be quoted separate.

Execution of IQ/OQ/PQ

Execution of IQ/OQ/PQ in accordance with qualification folder. Travel to be quoted separate

DL44-0500

Services

Execution of IQ/OQ/PQ - Execution of IQ/OQ/PQ in accordance with qualification folder. Travel to be quoted separate.

Unit installation

Connect the unit to the customer-side connections (electricity, water, wastewater, gas), basic functions check, brief operating instructions. (excl.: unpacking, setup, controller instructions, programming, installation work) Travel to be quoted as separate

DL10-0300

Services

Unit installation - Connect the unit to the customer-side connections (electricity, water, wastewater, gas), basic functions check, brief operating instructions. (excl.: unpacking, setup, controller instructions, programming, installation work) Travel to be quoted as separate.

Unit instructions

Instruction regarding operating principle and basic functions of the unit, operation of the control electronics including programming. Travel to be quoted as separate Limited to 3 hours

DL10-0700

Services

Unit instructions - Instruction regarding operating principle and basic functions of the unit, operation of the control electronics including programming. Travel to be quoted as separate Limited to 3 hours.

Leakage test

One-off maintenance service in accordance with maintenance schedule. Visual inspection of mechanical and electrical components, testing of all key functions. Calibration of a test temperature specified by the user in center of usable space without certificate

DL00-0034

Services

Leakage test - One-off maintenance service in accordance with maintenance schedule. Visual inspection of mechanical and electrical components, testing of all key functions. Calibration of a test temperature specified by the user in center of usable space without certificate

Preventive maintenance 

One-off maintenance service in accordance with maintenance schedule. Visual inspection of mechanical and electrical components, testing of all key functions. Checking a test temperature specified by the user in center of usable space without certificate. Wear + tear parts need to be purchased or billed to customer. Travel to be quoted as separate

DL20-0607

Services

Preventive maintenance  - One-off maintenance service in accordance with maintenance schedule. Visual inspection of mechanical and electrical components, testing of all key functions. Checking a test temperature specified by the user in center of usable space without certificate. Wear + tear parts need to be purchased or billed to customer. Travel to be quoted as separate.

SILVER 3-year maintenance contract

Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate 15% Discount on Spare Parts and Labor for any additional Services needed One additional courtesy visit per year can be used for service visit or operator training. Wear + tear parts to be purchased or billed to customer. Travel to be quoted separate

DL20-0830

Services

SILVER 3-year maintenance contract - Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate 15% Discount on Spare Parts and Labor for any additional Services needed One additional courtesy visit per year can be used for service visit or operator training. Wear + tear parts to be purchased or billed to customer. Travel to be quoted separate.

GOLD 3-year maintenance contract

Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate of Temperature, Humidity and pressure value. 25% Discount on Spare Parts and Labor for any additional Services needed. One additional courtesy visit per year can be used for service visit or operator. Wear + tear parts to be purchased or billed to customer. Travel to be quoted separate

DL20-0930

Services

GOLD 3-year maintenance contract - Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate of Temperature, Humidity and pressure value. 25% Discount on Spare Parts and Labor for any additional Services needed. One additional courtesy visit per year can be used for service visit or operator. Wear + tear parts to be purchased or billed to customer. Travel to be quoted separate.

Temperature calibration

Calibration of one (1) test temperature specified by the user in center of chamber, including certificate Travel to be quoted separate

DL30-0130

Services

Temperature calibration - Calibration of one (1) test temperature specified by the user in center of chamber, including certificate Travel to be quoted separate.

1-year warranty extension

The warranty is extended by 1 year from the delivery date, wear parts are excluded

DL50-0040

Services

1-year warranty extension - The warranty is extended by 1 year from the delivery date, wear parts are excluded