Model MKF 240 | Dynamic climate chambers for rapid temperature changes with humidity control

Benefits
  • Homogeneous climate conditions thanks to APT.line™ technology
  • Automatic water and wastewater management
  • Pressure humidification with fast response times
  • Comprehensive programming and data acquisition
  • Large heated viewing window

Configure your product with options and accessories and request it directly here.

Product description

A BINDER MKF series environmental simulation chamber is ideally suited for any cold and heat testing based on current temperature and climate testing methods according to DIN and IEC standards. The comprehensive standard equipment for this environmental simulation chamber ensures ease of operation.

Important characteristics

  • Temperature range: -40 °C to +180 °C
  • Humidity range: 10 % to 98 % RH
  • Integrated water-storage tank, 20 liters
  • 4 zero-voltage relay contacts
  • APT.line™ preheating chamber technology
  • Programmable condensation protection for test material
  • Heated viewing window with LED interior lighting
  • Humidity regulation with capacitative humidity sensor and vapor humidification
  • BINDER Multi Management Software APT-COM™ 4 Basic Edition
  • Troubleshooting system with visual and audible alarms
  • Intuitive touchscreen controller with time-segment and real-time programming
  • Internal data logger, measured values can be read out in open format via USB
  • Access port with silicone plug: 50 mm, left
  • Class 2 independent adjustable temperature safety device (DIN 12880) with visual alarm
  • 4 castors, two with brakes
  • Computer interface: Ethernet
  • Adjustable ramp function
  • Integrated chart recorder
  • Real-time clock
  • Door heating
  • Alarm notification in the event of insufficient water in fresh water tank
  • 1 stainless steel rack
  • Complete safety connection kit for water supply and drainage, up to 1 m height
  • Inner chamber made of stainless steel
  • CFC-free refrigerant R-452A
  • Cooling with compressor cooling unit

Technical specifications

Data
DesignationMKF240-400VMKF240-480V-C
Article Number9020-03809020-0358
Option model

Standard

Standard

Performance Data Temperature
Temperature range-40...180 °C-40...180 °C
Temperature uniformity dependent on set value0.1...1.5 ± K0.1...1.5 ± K
Temperature fluctuation dependent on set value0.1...0.5 ± K0.1...0.5 ± K
Average heating-up rate according to IEC 60068-3-55.0 K/min5.0 K/min
Cooling down time from 180°C to -40°C120 min120 min
Average cooling down time according to IEC 60068-3-55.0 K/min5.0 K/min
Performance Data Climate
Temperature range with humidity10...95 °C10...95 °C
Humidity range10...98 % r.F.10...98 % r.F.
Temperature fluctuation with humidity dependent on set value0.1...1.3 ± K0.1...1.3 ± K
Humidity fluctuation with humidity dependent on set value≤2,5 ± % r.F.≤2,5 ± % r.F.
Max. heat compensation at 25°C and 90% RH400 W400 W
Electrical data
Rated Voltage400 V480 V
Power frequency50 Hz60 Hz
Nominal power6,8 kW6,8 kW
Unit fuse16,0 A16,0 A
Phase (Nominal voltage)3~/N/PE3~
Dimensions and weights
Interior volume8 cu.ft.8 cu.ft.
Net weight of the unit (empty)794 lbs794 lbs
Load per rack66 lbs66 lbs
Permitted load154 lbs154 lbs
Wall clearance back11,81 in11,81 in
Wall clearance sidewise7,87 in7,87 in
Housing dimensions not incl. fittings and connections
Width net43.9 in43.9 in
Height net67.52 in67.52 in
Depth net36.42 in36.42 in
Internal Dimensions
Interior width28.94 in28.94 in
Interior height27.56 in27.56 in
Interior depth17.44 in17.44 in
Unit doors11
Environment-specific data
Sound-pressure level65 dB(A)67 dB(A)
Energy consumption at 25°C and 60% RH1,500 Wh/h1,500 Wh/h
Fixtures
Number of shelves (std./max.)1/61/6

Downloads

Dynamic climate chambers

MK | MKF | MKT | MKFT series

pdf, 2.3 MB

PURE AQUA SERVICE

Series KBF-S | KBF-S ECO | KBF| KBF P | KBF LQC | KMF | KBWF | MKF | MKFT

pdf, 340.4 KB

Drying and heating chambers (FP series) - Drying chambers, constant climate chambers, dynamic climate chambers and cooling incubators test the service life of MinebeaMitsumi spindle motors

MinebeaMitsumi Technology Center Europe GmbH

pdf, 479.77 KB

MKF | MKFT series

pdf, 18.06 MB

Data Sheet Model MKF 240

pdf, 1.06 MB

Options, Accessories, Services

Sorry, no result could be found. Check the spelling or use a new search term.

Rack accessories

Fasteners (1 set of 4) for additional security of racks

8012-2280

BINDER PURE AQUA SERVICE

System for preparation or complete desalination of tap water, complete set containing PURE AQUA 300 single-use cartridge, measuring device, and all necessary connecting parts

8012-0759

BINDER PURE AQUA Service

BINDER PURE AQUA SERVICE - System for preparation or complete desalination of tap water, complete set containing PURE AQUA 300 single-use cartridge, measuring device, and all necessary connecting parts

BINDER PURE AQUA SERVICE, accessories

Single-use, replacement cartridge for BINDER PURE AQUA System

6011-0165

Accessorie-cartridge%20-%206011-0165_Web_670x515.jpg

BINDER PURE AQUA SERVICE, accessories - Single-use, replacement cartridge for BINDER PURE AQUA System  

Qualification documents

IQ/OQ documents – supporting documents for validation performed by customers, consisting of: IQ/OQ checklists incl. calibration guide and comprehensive unit documentation; parameters: temperature and humidity values. Hard copy inside folder

7007-0002

Qualification documents

IQ/OQ documents – supporting documents for validation performed by customers, consisting of: IQ/OQ checklists incl. calibration guide and comprehensive unit documentation; parameters: temperature and humidity values. Digital in PDF format

7057-0002

Qualification documents

IQ/OQ/PQ documents – supporting documents for validation performed by customers, according to customer requirements, PQ section added to qualification folder IQ/OQ; parameters: temperature and humidity values. Hard copy inside folder

7007-0006

Qualification documents

IQ/OQ/PQ documents – supporting documents for validation performed by customers, according to customer requirements, PQ section added to qualification folder IQ/OQ; parameters: temperature and humidity values. Digital in PDF format

7057-0006

Rack

Stainless steel

8012-2053

Shelves

Rack - stainless steel

Rack, reinforced

Stainless steel, with fasteners (1 set of 4)

8012-0605

Shelf

Rack, reinforced - stainless steel, with fasteners (1 set of 4)

Shelf, perforated

Stainless steel

8012-2251

Shelf

Shelf, perforated - Stainless steel

RS 485 / RS 422 interface converter

RS 422 cable set and RS 485 / RS 422 interface converter for connection to 10-way plug distributor. 115 V option model

8012-0599

RS 485 / RS 422 interface converter

RS 422 cable set and RS 485 / RS 422 interface converter for connection to 10-way plug distributor. 230 V option model

8012-0589

APT-COM™ 4 PROFESSIONAL-Edition

Convenient unit and user management built on the BASIC edition. Suitable for networking up to 100 units.. version 4, PROFESSIONAL edition

9053-0040

Multi Management Software APT-COM™

APT-COM™ 4 PROFESSIONAL-Edition - convenient unit and user management built on the BASIC edition. Suitable for networking up to 100 units.

APT-COM™ 4 GLP-Edition

For working under GLP-compliant conditions. Measured values are documented in a tamper-proof way in line with the requirements of FDA Regulation 21 CFR 11.. version 4, GLP edition

9053-0042

Multi Management Software APT-COM™

APT-COM™ 4 GLP-Edition - for working under GLP-compliant conditions. Measured values are documented in a tamper-proof way in line with the requirements of FDA Regulation 21 CFR 11.

pH-neutral detergent

Concentrated, for gentle remove of residual contaminants; 1 kg

8012-2250

1002-0016-Neutralreiniger-100x85_Web_670x515.jpg

pH-neutral detergent - concentrated, for gentle remove of residual contaminants; 1 kg

Sorry, no result could be found. Check the spelling or use a new search term.

Access port with silicone plug

Right. 30 mm

8012-1320

Access port with silicone plug

Access port with silicone plug - 30 mm, right

Access port with silicone plug

Left. 30 mm

8012-1323

Access port with silicone plug

Access port with silicone plug - 30 mm, left

Access port with silicone plug

Right. 50 mm

8012-1326

Access port with silicone plug

Access port with silicone plug - 50 mm, right

Access port with silicone plug

Left. 50 mm

8012-1329

Access port with silicone plug

Access port with silicone plug - 50 mm, left

Access port with silicone plug

Right. 80 mm

8012-1332

Access port with silicone plug

Access port with silicone plug - 80 mm, right

Access port with silicone plug

Left. 80 mm

8012-1335

Access port with silicone plug

Access port with silicone plug - 80 mm, left

Access port with silicone plug

Top. 80 mm

8012-1537

Access port with silicone plug

Access port with silicone plug - 80 mm, top

Calibration certificate, temperature and humidity

Measurement in center of chamber at 25°C / 60% RH or at specified test values

8012-1188

Calibration certificate, expanded

For temperature and humidity; for extending the measurement in center of chamber to include another test value  

8012-1194

Calibration certificate, temperature

Temperature measurement incl. certificate, 9 measuring points at specified temperature

8012-1568

Calibration certificate, temperature

Temperature measurement incl. certificate, 15- 18 measuring points at specified temperature

8012-1589

Calibration certificate, temperature

Temperature measurement incl. certificate and 27 measuring points at specified temperature

8012-1609

Calibration certificate, temperature and humidity

Temperature (according to DIN12880) and humidity measurement incl. certificate, 27 temperature measuring points and 1 humidity measuring point, at 25 °C / 60 % RH or at specified values

8012-1615

Analog output 4-20 mA

For temperature and humidity values (output not adjustable)

8012-1085

Pt 100 temperature sensor

Additional flexible Pt 100, interior, for displaying the temperature on the unit display

8012-1094

Pt 100 temperature sensor

Pt 100 temperature sensor - additional flexible Pt 100, interior, for displaying the temperature on the unit display

RS 485 interface, 2-wire

Additional serial interface can be used parallel to Ethernet, for Multi Management Software APT-COM™

8012-1769

Door lock

Lockable door handle

8012-1862

Door lock

Door lock - lockable door handle

Temperature safety device class 2

With visual alarm (DIN 12880)

8012-1864

Water circuit

  allows condensed water to be reused

8012-1512

Access port with silicone plug

Right. 125 mm

8012-1349

Access port with silicone plug

Access port with silicone plug - 125 mm, right

Access port with silicone plug

Left. 125 mm

8012-1352

Access port with silicone plug

Access port with silicone plug - 125 mm, left

Access port with silicone plug

Top. 100 mm

8012-1531

Access port with silicone plug

Access port with silicone plug - 100 mm, top

Access port with silicone plug

Top. 125 mm

8012-1534

Access port with silicone plug

Access port with silicone plug - 125 mm, top

Access port with silicone plug

Right. 100 mm

8012-1540

Access port with silicone plug

Access port with silicone plug - 100 mm, right

Access port with silicone plug

Left. 100 mm

8012-1543

Access port with silicone plug

Access port with silicone plug - 100 mm, left

Compressed air connection

For the connection to an existing pressurized air network

8012-1787

Dry-air purge

Compressed air connection - for the connection to an existing pressurized air network

Dry-air purge

Controlled, incl. connection; suitable for the simulation of current automobile industry standards

8012-1869

Dry-air purge

Dry-air purge - controlled, incl. connection; suitable for the simulation of current automobile industry standards

Notch-type access port

Notch-type access port in door, 100 x 35 mm

8012-1856

Notch-type access port in door

Notch-type access port - notch-type access port in door, 100 x 35 mm

Water cooling

For reduced heat loss to ambient air

8012-0842

Sorry, no result could be found. Check the spelling or use a new search term.

BRONZE 3-year maintenance contract

Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate. 10% Discount on Spare Parts and Labor for any additional Services needed Wear + tear parts to be purchased or billed to customer. Travel to be quoted as separate

DL20-0710

Services

BRONZE 3-year maintenance contract - Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate. 10% Discount on Spare Parts and Labor for any additional Services needed Wear + tear parts to be purchased or billed to customer. Travel to be quoted as separate.

Execution of IQ/OQ/PQ

Execution of IQ/OQ/PQ in accordance with qualification folder. Travel to be quoted separate

DL44-0500

Services

Execution of IQ/OQ/PQ - Execution of IQ/OQ/PQ in accordance with qualification folder. Travel to be quoted separate.

Unit installation

Connect the unit to the customer-side connections (electricity, water, wastewater, gas), basic functions check, brief operating instructions. (excl.: unpacking, setup, controller instructions, programming, installation work) Travel to be quoted as separate

DL10-0300

Services

Unit installation - Connect the unit to the customer-side connections (electricity, water, wastewater, gas), basic functions check, brief operating instructions. (excl.: unpacking, setup, controller instructions, programming, installation work) Travel to be quoted as separate.

Unit instructions

Instruction regarding operating principle and basic functions of the unit, operation of the control electronics including programming. Travel to be quoted as separate Limited to 3 hours

DL10-0700

Services

Unit instructions - Instruction regarding operating principle and basic functions of the unit, operation of the control electronics including programming. Travel to be quoted as separate Limited to 3 hours.

Leakage test

One-off maintenance service in accordance with maintenance schedule. Visual inspection of mechanical and electrical components, testing of all key functions. Calibration of a test temperature specified by the user in center of usable space without certificate

DL00-0034

Services

Leakage test - One-off maintenance service in accordance with maintenance schedule. Visual inspection of mechanical and electrical components, testing of all key functions. Calibration of a test temperature specified by the user in center of usable space without certificate

1-year warranty extension

The warranty is extended by 1 year from the delivery date, wear parts are excluded

DL50-0040

Services

1-year warranty extension - The warranty is extended by 1 year from the delivery date, wear parts are excluded

Preventive maintenance 

One-off maintenance service in accordance with maintenance schedule. Visual inspection of mechanical and electrical components, testing of all key functions. Checking a test temperature specified by the user in center of usable space without certificate. Wear + tear parts need to be purchased or billed to customer. Travel to be quoted as separate

DL20-0610

Services

Preventive maintenance  - One-off maintenance service in accordance with maintenance schedule. Visual inspection of mechanical and electrical components, testing of all key functions. Checking a test temperature specified by the user in center of usable space without certificate. Wear + tear parts need to be purchased or billed to customer. Travel to be quoted as separate.

SILVER 3-year maintenance contract

Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate 15% Discount on Spare Parts and Labor for any additional Services needed One additional courtesy visit per year can be used for service visit or operator training. Wear + tear parts to be purchased or billed to customer. Travel to be quoted separate

DL20-0835

Services

SILVER 3-year maintenance contract - Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate 15% Discount on Spare Parts and Labor for any additional Services needed One additional courtesy visit per year can be used for service visit or operator training. Wear + tear parts to be purchased or billed to customer. Travel to be quoted separate.

GOLD 3-year maintenance contract

Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate of Temperature. 25% Discount on Spare Parts and Labor for any additional Services needed. One additional courtesy visit per year can be used for service visit or operator. Wear + tear parts to be purchased or billed to customer. Travel to be quoted separate

DL20-0935

Services

GOLD 3-year maintenance contract - Annual Device Inspection Includes Preventive Maintenance with Calibration Certificate of Temperature. 25% Discount on Spare Parts and Labor for any additional Services needed. One additional courtesy visit per year can be used for service visit or operator. Wear + tear parts to be purchased or billed to customer. Travel to be quoted separate.

Temperature and humidity calibration

Expansion –Additional Temperature and humidity calibration with 1 measuring point in center of chamber with 1 specified pair of values, including certificate. Travel to be quoted separate

DL30-0302

Services

Temperature and humidity calibration - Expansion –Additional Temperature and humidity calibration with 1 measuring point in center of chamber with 1 specified pair of values, including certificate. Travel to be quoted separate.

Temperature measurement, 9 temperature measuring points and 1 humidity measuring point

Temperature measurement with 9 temperature measuring points and 1 humidity measuring point in center of chamber with a pair of values specified by the user, including certificate. Travel to be quoted separate.  A total of 3 shelves are required

DL30-0309

Services

Temperature measurement, 9 temperature measuring points and 1 humidity measuring point - Temperature measurement with 9 temperature measuring points and 1 humidity measuring point in center of chamber with a pair of values specified by the user, including certificate. Travel to be quoted separate.  A total of 3 shelves are required.

Temperature measurement, 18 temperature measuring points and 1 humidity measuring point

Temperature measurement with 18 temperature measuring points and 1 humidity measuring point in center of chamber with a pair of values specified by the user, including certificate. Travel to be quoted separate.  A total of 2 shelves are required

DL30-0318

Services

Temperature measurement, 18 temperature measuring points and 1 humidity measuring point - Temperature measurement with 18 temperature measuring points and 1 humidity measuring point in center of chamber with a pair of values specified by the user, including certificate. Travel to be quoted separate.  A total of 2 shelves are required.

Temperature measurement, 27 temperature measuring points and 1 humidity measuring point

Temperature measurement with 27 temperature measuring points and 1 humidity measuring point in center of chamber with a pair of values specified by the user, including certificate. Travel to be quoted separate.  A total of 3 shelves are required

DL30-0327

Services

Temperature measurement, 27 temperature measuring points and 1 humidity measuring point - Temperature measurement with 27 temperature measuring points and 1 humidity measuring point in center of chamber with a pair of values specified by the user, including certificate. Travel to be quoted separate.  A total of 3 shelves are required.

Temperature and humidity calibration

Temperature and humidity calibration with 1 measuring point in center of chamber with 1 specified pair of values, including certificate. Travel to be quoted separate

DL30-0330

Services

Temperature and humidity calibration - Temperature and humidity calibration with 1 measuring point in center of chamber with 1 specified pair of values, including certificate. Travel to be quoted separate.

Temperature and humidity measurement according to DIN12880

Temperature measurement in accordance with DIN 12880 with 27 temperature measuring points and 1 humidity measuring point in center of chamber with a pair of values specified by the user, including certificate

DL30-0427

Services

Temperature and humidity measurement according to DIN12880 - Temperature measurement in accordance with DIN 12880 with 27 temperature measuring points and 1 humidity measuring point in center of chamber with a pair of values specified by the user, including certificate

Execution of IQ/OQ

Execution of IQ/OQ in accordance with qualification folder. Travel to be quoted separate

DL42-0300

Services

Execution of IQ/OQ - Execution of IQ/OQ in accordance with qualification folder. Travel to be quoted separate.

Suggested products

Compare products:

Or add another product.