Model 115
Model 115
Dimensions
VDL-MB2-Regler-100-85_Web_670x515.jpg
Optional equipment: additional expansion racks
VD-VDL-Detailbild_E3-100-85_Web_670x515.jpg
Optional equipment: pump chamber with vacuum pump
Product image
Product image
Product image
Product image
Product image
Product image
Product image

Model VDL 115 | Vacuum drying chambers for flammable solvents

Benefits
  • Fast, gentle drying
  • Optimum heat transfer through large thermal conducting plates
  • Safe working thanks to ATEX-compliant safety concept
  • Also option of modular complete system with vacuum pump and pump chamber

Configure your product with options and accessories and request it directly here.

Product description

BINDER VDL series safety vacuum drying chambers ensure maximum safety when drying organic solvents. Explosion-protected unit with classification according to ATEX directive 2014/34/EU: EX II 2/3/- G IIB T3 Gb/Gc/- X.

Important characteristics

  • Temperature range: +9°C above ambient temperature to +110 °C
  • ATEX conformity for units: EX II 2/3/- G IIB T3 Gb/Gc/- X
  • Intuitive touchscreen controller with graphical pressure and temperature display
  • Program-controlled drying monitoring with automatic ventilation at end of process
  • Internal data logger, measured values can be read out in open format via USB
  • Pressure control device for heating activated from < 100 mbar
  • 2 aluminum expansion racks, can be custom-positioned
  • Universal connection for ventilation with ambient air or inert gas
  • Universal access port DN 16 - for the introduction of external measuring devices
  • Shatterproof, spring-mounted safety glass panel
  • Large viewing window
  • Computer interface: Ethernet

Technical specifications

Data
DesignationVDL115-230V

VDL115-120V

Article Number9630-00119630-0015
Option model

Standard

Standard

Performance Data Temperature
Temperature range+9 °C above ambient temperature to 110 °C+9 °C above ambient temperature to 110 °C
Temperature uniformity at 100°C2.9 ± K2.9 ± K
Temperature fluctuation at 100°C0.1 ± K0.1 ± K
Heating up time to 100°C170 min170 min
Vacuum Data
Leckrate0,01 bar/h0,01 bar/h
Electrical data
Rated Voltage200...230 V100...120 V
Power frequency50/60 Hz50/60 Hz
Nominal power1,6 kW1,6 kW
Unit fuse10,0 A20,0 A
Phase (Nominal voltage)1~1~
Connections
Vacuum connection with small flange16 DN mm16 DN mm
Measuring access port with small flange16 DN mm16 DN mm
Measures
Interior volume119 L119 L
Net weight of the unit (empty)158 kg158 kg
Load per rack20 kg20 kg
Permitted load70 kg70 kg
Wall clearance back100 mm100 mm
Wall clearance sidewise70 mm70 mm
Housing dimensions not incl. fittings and connections
Width net743 mm743 mm
Height net942 mm942 mm
Depth net581 mm581 mm
Internal Dimensions
Interior width506 mm506 mm
Interior height506 mm506 mm
Interior depth460 mm460 mm
Viewing window width525 mm525 mm
Viewing window height468 mm468 mm
Unit doors11
Environment-specific data
Sound-pressure level40 dB(A)40 dB(A)
Energy consumption at 100°C230 Wh/h230 Wh/h
Fixtures
Number of shelves (std./max.)2/62/6

Downloads

Vacuum drying chambers

VD | VDL series

pdf, 1.37 MB

VAP 5 vacuum pump

ATEX chemical membrane pump VDL series

pdf, 144.89 KB

Drying and heating chambers (FP series) - Drying chambers, constant climate chambers, dynamic climate chambers and cooling incubators test the service life of MinebeaMitsumi spindle motors

MinebeaMitsumi Technology Center Europe GmbH

pdf, 479.77 KB

VDL series

pdf, 10.66 MB

VAP 5 Vacuum Pumps

For vacuum drying oven VDL

pdf, 7.61 MB

Data Sheet Model VDL 115

pdf, 124.15 KB

Compare products: